5
OTHER FUNCTIONS
5-6
Using the Emergency Call function (Continued)
The transceiver enters the Emergency mode through
the following functions, depending on a presetting:
D
The Man Down function
When the transceiver is tilted past the preset angle for
the ON Timer preset time, the transceiver enters the
Emergency mode�
L
If a user raises the transceiver back from the preset
angle towards the vertical position before the
Reminder Timer set time expires, the Emergency
mode is canceled�
Angle
Time
Past the preset degrees
ON Timer
Reminder Timer
Emergency Timer
Enters the
Emergency mode.
Sends an
Emergency call.
Preset angle
If raised back from the preset
angle during the Reminder
Timer, the Emergency mode
is canceled.
If raised back from the preset
angle during the Reminder
Timer, the Emergency mode
is canceled.
Angle
Acceleration
Time
Enters the
Emergency mode.
Sends an
Emergency call.
Stationary
Sensitivity
ON Timer
Reminder Timer
Emergency Timer
Preset angle
If moving during the Reminder
Timer, the Emergency mode
is canceled.
No motion is
detected.
Past 45 degrees
Man Down With Stationary:
• The transceiver leans past the preset angle for the
ON Timer preset time�
AND
• The transceiver is detected as stationary (no motion)
for the ON Timer set time�
L
If a user raises the transceiver back from the preset
angle towards the vertical position, or when the
user moves the transceiver before the Reminder
Timer set time expires, the Emergency mode is
canceled�
NOTE:
The Man down function may not properly work, depending on the surrounding environment such as
obstructions, weather condition, and so on�
Icom is not responsible for the destruction or damage caused by using the Man Down function�