background image

20

7

PRIORITY WATCH

Priority watch types

Priority watch checks for signals on a frequency every 5 sec.
while operating on a VFO frequency or scanning. The receiver
has 3 priority watch types to suit your needs.

In addition, you can be alerted with beeps and a flashing “

ë

.”

The watch resumes according to the selected scan resume
condition. See p. 18 for details.

If the pocket beep function is activated, the receiver auto-
matically selects the tone squelch function when priority
watch starts.

MEMORY CHANNEL
WATCH

While operating on a VFO
frequency, priority watch
checks for a signal on the
selected memory channel
every 5 sec.

• A memory channel with skip in-

formation can be watched.

MEMORY SCAN WATCH

While operating on a VFO
frequency, priority watch
checks for signals on each
memory channel in se-
quence.

• The memory skip function

and/or memory bank scan is
useful to speed up the scan.

VFO SCAN WATCH

While scanning in VFO
mode, priority watch checks
for signals on the selected
memory channel every 5
sec.

Memory

channel

VFO

frequency

5 sec.

125 msec.

VFO

frequency

Mch 1

Mch 0

Mch 2

Mch 49

5 sec.

125 msec.

SKIP

VFO

scanning

Memory

channel

5 sec.

125 msec.

Содержание IC-R2

Страница 1: ...he FCC rules Operation is sub ject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that...

Страница 2: ...s with temperatures below 10 C 14 F or above 60 C 140 F Even when the receiver power is OFF a slight current still flows in the circuits Remove batteries from the receiver when not using it for a long...

Страница 3: ...gy from 0 495 MHz to 1309 995 MHz and converts it into audio frequency AF energy which in turn ac tuates a loudspeaker to create sound waves AF energy is in the range of 20 to 20 000 Hz kHz is an abbr...

Страница 4: ...election 13 Transferring memory contents to another memory 13 Memory bank selection 14 Memory clear 14 6 SCAN OPERATION 15 19 Scan types 15 Full band programmed scan 16 Memory bank scan 16 Selecting s...

Страница 5: ...BNC con nector DBattery installation q Remove the battery cover from the receiver w Install 2 R6 AA size al kaline dry cell or Ni Cd batteries Be sure to observe the cor rect polarity Charge Ni Cd ba...

Страница 6: ...itches and tuning dial perform secondary functions Push FUNC a switch means while pushing the FUNC switch push the switch r BAND SWITCH BAND Push to select the operating band VHF UHF etc p 6 Broadcast...

Страница 7: ...gle the frequency skip function ON or OFF in VFO mode p 19 Push FUNC TS SKIP for 2 sec to program the dis played frequency as a skip frequency during full band or programmed scan p 19 Push FUNC TS SKI...

Страница 8: ...ion r ATTENUATOR INDICATOR Appears when the attenuator function is in use p 8 t FREQUENCY READOUT Shows the operating frequency set mode contents etc The smaller 75 50 and 25 to the right of the reado...

Страница 9: ...can in memory mode 0 SIGNAL INDICATORS Shows the relative signal strength while receiving 1 PRIORITY WATCH INDICATOR p 20 Appears when priority watch is in use 2 BUSY INDICATOR BUSY appears when recei...

Страница 10: ...the VFO Operating band selection The receiver can receive the broadcast band HF band 50 MHz band VHF avionics band 144 MHz band 300 MHz band 400 MHz band 800 MHz band or 1200 MHz band Push BAND sever...

Страница 11: ...25 kHz 10 kHz 12 5 kHz 15 kHz 20 kHz 25 kHz 30 kHz 50 kHz 100 kHz DUsing the TS switch q Select VFO mode with V M w Select the desired band with BAND e Push TS to enter tuning step set ting condition...

Страница 12: ...still be accessed while the lock function is ON default Accessible switches can be set to 1 of 4 groups in expanded set mode See p 28 for details Attenuator function The attenuator prevents a desired...

Страница 13: ...evel While pushing SQL rotate DIAL The first click of DIAL indicates the current squelch level LEVEL1 is loose squelch and LEVEL9 is tight squelch AUTO indicates automatic level adjustment with a nois...

Страница 14: ...a continuously open setting and an automatic squelch setting While pushing SQL rotate the DIAL to select the squelch level The first click of DIAL indicates the current squelch level LEVEL1 is loose...

Страница 15: ...with a 5 sec timer for nighttime operation The display backlighting can be turned ON continuously or turned OFF if desired Push any switch except FUNC or rotate DIAL to turn the backlighting ON When a...

Страница 16: ...requency duplex direction tone squelch frequency etc if required e Push FUNC V M MW momentarily to indicate memory channels Do not hold FUNC V M MW for more than 0 5 sec other wise the previously sele...

Страница 17: ...ed Transferring memory contents to another memory q Select memory mode with V M w Select the memory channel to transfer with DIAL Rotate DIAL while pushing FUNC to select a memory bank or programmed s...

Страница 18: ...cannot be recalled q Select memory mode with V M w Set the memory channel to be cleared with DIAL Rotate DIAL while pushing FUNC to select a memory bank or programmed scan edge channel e Select VFO mo...

Страница 19: ...the entire selected band Scan Jump Scan Jump Scan edges MEMORY SKIP FUNCTION p 18 Skips unwanted memory channels that inconvenient ly stop scanning Skip channels can be toggled ON and OFF by pushing F...

Страница 20: ...oes not start For programmed scan scan edges must be programmed in advance Program scan edges in the same manner of programming a memory channel and select a scan edge p 17 Memory bank scan q Select m...

Страница 21: ...ired scan edge frequencies in a pair of programmed scan edge channels in advance pgs 12 13 q Select VFO mode with V M w While pushing FUNC push BAND to enter band edge set mode e Rotate DIAL to select...

Страница 22: ...s according to the scan pause time It can be set from 2 20 sec or unlimited q Push V M for 2 sec to enter expanded set mode w Rotate DIAL until PAUSE appears Turn the expanded set mode ON for selectio...

Страница 23: ...ls are used for skip frequency programming in reverse sequence To scan the skip frequency after programming cancel the skip information p 18 or clear the memory channel p 14 DFrequency skip function O...

Страница 24: ...watch starts MEMORY CHANNEL WATCH While operating on a VFO frequency priority watch checks for a signal on the selected memory channel every 5 sec A memory channel with skip in formation can be watche...

Страница 25: ...cted scan resume con dition p 18 u Push V M while the display shows the VFO frequency to stop the watch DVFO scan watch q Select the desired memory channel to be watched w Push V M to select VFO mode...

Страница 26: ...he squelch manually push and hold SQL i To cancel the tone squelch repeat steps e y as de scribed above and select OFF in step t DSetting subaudible tones for tone squelch operation q Select VFO mode...

Страница 27: ...V M to stop the beeps and flashing Tone squelch is automatically selected The receiver has 50 tone frequencies and consequently their spacing is narrow compared with units having 38 tones Therefore so...

Страница 28: ...ex shift direction q Push V M for 2 sec to enter expanded set mode w Rotate DIAL until DUP appears Turn the expanded set mode ON for selection p 25 DUP disappears after 1 sec and dP appears e While pu...

Страница 29: ...hing FUNC rotate DIAL to turn the expanded set mode ON or OFF r Push V M to exit set mode or rotate DIAL to select a set mode item DSet mode items E Appears when expanded set mode is ON B Does not app...

Страница 30: ...elected t Push V M to exit set mode Beep tones The confirmation beep tones which sound each time a switch is pushed can be turned ON or OFF as desired q Push V M for 2 sec to enter set mode w Rotate D...

Страница 31: ...and AO appears e While pushing FUNC rotate DIAL to select the desired time or to turn the function OFF r Push V M to exit set mode Monitor switch action The monitor switch can be set as a sticky switc...

Страница 32: ...ction access While the lock function is ON POWER VOL and SQL can still be accessed Accessible switches can be set to 1 of 4 groups in expanded set mode q Push V M for 2 sec to enter expanded set mode...

Страница 33: ...rogrammed into memory channels in advance Cloning function The IC R2 has receiver to receiver data cloning capability This function is useful when you want to copy all of the pro grammed contents from...

Страница 34: ...is available for the receiver While pushing FUNC and V M turn power ON to par tially reset the receiver All reset Reset the CPU before operating the receiver for the first time or when the internal CP...

Страница 35: ...ected Push FUNC MODE LOCK to cancel the function Turn the channel indication mode OFF in set mode p 8 p 29 No beeps sound Beep tones are turned OFF Turn beep tones ON in set mode p 26 Receive audio is...

Страница 36: ...769 8 960 095 MHz 960 1 1309 995 MHz 0 495 1 620 MHz 1 625 29 995 MHz TS SKIP TS SKIP V M MW V M MW BAND FUNC BAND BAND FUNC BAND V M MW V M MW momentarily for 2 sec VFO mode Memory mode TS SKIP TS SK...

Страница 37: ...atch p 21 Priority watch p 21 Confirmation beep p 26 Confirmation beep p 26 Backlighting p 11 Auto power OFF p 27 Power save p 26 Monitor switch action p 27 Dial speed p 28 Lock function effect p 28 C...

Страница 38: ...yp Power saved 41 mA typ Antenna connector SMA 50 Dimensions 58 W 86 H 27 D mm projections not included 29 32 W 33 8 H 11 16 D in Weight 170 g 6 oz w antenna and battery DReceiver Receive system Tripl...

Страница 39: ...protect the receiver from scratches etc SP 13 EARPHONE Provides clear receive audio in noisy environments HP 4 HEADPHONE Provides increased readability of signals in noisy environ ments and listening...

Страница 40: ...Count on us 6 9 16 Kamihigashi Hirano ku Osaka 547 0002 Japan A 5520H 1EX Printed in Japan 1998 Icom Inc...