3 - 3
(2) TUNING CONTROLS (MAIN UNIT)
A motor driver (IC15) rotates the tuning motors (MF1, MF2)
to obtain a low SWR.
(3) TUNING RELAYS (C-NET, L-NET AND H-NET
BOARDS)
According to the operating frequency band and antenna
condition, tuning relays select the capacitors and coils.
3-3 PROTECTION CIRCUITS
3-3-1 GENERAL
The IC-PW1 has two protection systems. One system
bypasses the power amplifier, and the other system shuts
down the internal power supply activation.
Protection activates when:
• a mismatched frequency band signal is transmitted.
• the ALC control level exceeds the control range.
• the power level balance between the 4 PA units becomes
unbalanced.
• the output voltage of the internal power supply (V
D
)
exceeds 55 V DC.
• the current of the power amplifiers (I
D
) exceeds 50 A.
• the heatsink temperature of the power amplifier exceeds
+100˚C (212˚F).
• the applied AC voltage exceeds the specified value.
The main CPU controls the THROUGH/AMP switch and
internal power supply operation.
3-3-2 ALC CIRCUIT (MAIN UNIT)
The ALC (Automatic Level Control) circuit automatically lim-
its RF output power by controlling the input level of the
exciter.
(1) FOR-ALC
The detected “FOR” voltage signal from the SWR detector
circuit (FILTER unit; D15, D16, L22) is op-amplified at IC1a
then applied to the ACC2 socket (JACK1 unit; J5, pin 5) via
the ALC adjustment pot (JACK1 unit; R1) and ALC2 jack
(JACK2 unit; J7).
(2) I
D
-ALC
In the IC-PW1, internal power supply voltage (I
D
) is used for
I
D
-ALC. The power supply voltage (I
D
) is amplified at the op-
amplifier (IC1c), then applied to the ACC2 socket.
(3) SWR-ALC
SWR-ALC protects the power amplifiers (PA1–PA4 boards;
Q1a/b) when SWR worsens and when dielectric break-
down/discharge from excessive voltage rises.
The detected “REF” voltage signal from the SWR detector
circuit (FILTER unit; D15, D16, L22) is op-amplified at the
SWR/DRIVE amplifier (IC1b) then applied to the ACC2
socket (JACK1 unit; J5, pin 5).
(4) DRV-ALC
DRV-ALC activates when the exciter input exceeds 120 W
to protect the power amplifiers. The op-amplified “REF” sig-
nal at the SWR/DRIVE amplifier (IC1b) is used for operation.
However, the limiter circuit on the SPRITR unit (D4, D5) is
activated for momentary excessive input such as leading
edge power, etc.
3-3-3 DRIVING POWER DETECTOR CIRCUIT
(SPLITR AND MAIN UNITS)
A portion of the attenuated input power from the exciter input
switching circuit (SPLITR unit; RL1) is divided by R7 and R8,
and then rectified at D3, R2 and C5 for conversion to DC
voltages. The rectified DC voltages are applied to the drive
amplifier (MAIN unit; IC21a/b). The amplified DC voltages
are applied to the main CPU (MAIN unit; IC26)
• ALC CIRCUITS
From SPLITR unit
RL5
From TUNER unit
"T13" from MAIN unit
VSWR detector
D15, D16, L22
RF power control
IC1
ACC socket1,
pin 5
ALC selector
ALC1
ALC2
Relay driver
IC18
ACC socket2,
pin 5
Main CPU IC26
RL1
ALC amp.
5
7
3
1
Id control
Regurator
IC1
FOR
SWR/DRIVE
control
IC1
REF
6
7
2
1
To DET board
FILTER UNIT
9
8
Содержание IC-PW1
Страница 1: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 16 VOLTAGE DIAGRAM 18 Mar 2011 ...
Страница 24: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 16 Jun 2010 ...
Страница 42: ...SERVICE MANUAL ADDENDUM CONTENTS PARTS LIST 1 BOARD LAYOUTS 16 VOLTAGE DIAGRAM 18 Apr 2010 ...
Страница 96: ...HF 50 MHz ALL BAND LINEAR AMPLIFIER iC PW1 ...
Страница 175: ...MNF F1 EP2 TO REGRELAY BOARD MLF EP1 F2 TO REGRELAY BOARD EP35 I N FG 8 19 FIL AC BOARD 8 20 ...
Страница 178: ...380G TO ACTFIL BOARD 380G 380H 380G TO CONV BOARD EP4 EP33 EP33 380H 380H EP3 EP32 EP32 EP31 8 23 8 22 ACT C BOARD ...
Страница 201: ...A 5449MZ S 3 1999 Icom Inc 1 1 32 Kamiminami Hirano ku Osaka 547 0003 Japan Count on us ...