7
3
SELECTING A CHANNEL/FREQUENCY
D
Using scan functions
(Some versions do not have these functions)
The transceiver has automatic channel or frequency
change capability (scan function). There are 3 types
of scan functions available to suit your needs.
Channel scan and channel resume scan increase
channels within a 5 channel range such as ch 1 to ch
5, ch 156 to ch 160, etc. in user channels; or all chan-
nels in the group of ITU channels.
Programmed scan (optional) changes frequencies
within the frequency range between user channels
159 and 160.
Scan selection is available in set mode. See p. 14 for
scan selection.
SCAN OPERATION
➀
Select your desired channel group with the
[GROUP] and [CHANNEL] selector.
• Or use the keypad and [CE] key for direct selection.
• This operation is not necessary for programmed scan.
➁
Push [SQL] to turn OFF the squelch function if pro-
grammed scan is selected.
➂
Push [FUNC] then [SQL] to start the scan.
➃
To stop the scan, repeat step
➂
again.
• [CHANNEL] rotation and some other switches also stop
the scan.
Channel scan
ch 1
ch 2
ch 3
ch 4
ch 5
scan is
cancelled
when
transmitting
Channel resume scan
ch 1
ch 2
ch 3
ch 4
ch 5
scan pauses
for 30 sec.,
then resumes
after
transmitting
D
Using the keypad
Direct channel selection via the keypad is available
for quick channel selection.
➀
Make sure “
s
” does not appear on the display.
• If it appears, push [CE] to delete it.
➁
Enter the desired channel number via the keypad.
• A user channel is selected when channel 1–160 is input
(max. number may be optionally restricted).
• An ITU SSB channel is selected when channel num-
bers higher than 401 are input (not available for some
versions).
• An ITU FSK channel is selected when channel numbers
higher than 4001 are input (not usable according to set
mode setting).
• The “–” key can be used for selecting an ITU simplex
channel.
➂
Push [RX] to select the entered channel.
[EXAMPLE]:
Selecting channel 153
D U P
T X
RX
D S C
F
AGC
A L M
D U P
T X
RX
D S C
F
AGC
A L M
D U P
T X
RX
D S C
F
AGC
A L M
D U P
T X
RX
D S C
F
AGC
A L M
D U P
T X
RX
D S C
F
AGC
A L M
1
5
3
RX
Programmed scan
(optional)
ch 159
ch 160
Scans the frequency range
between the programmed
frqeuencies on channels
159 and 160.
Scans fast when squelch is
closed and slowly when
squelch is open.
IC-M710RT.qxd 02.1.9 9:03 Page 7