background image

17

3

CONNECTION AND MAINTENANCE

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16

 Antenna

A key element in the performance of any communication sys-
tems is its antenna. Contact your dealer for more information 
regarding antennas and how to install them.

 Fuse replacement

If a fuse blows or the transceiver stops functioning, track 
down the source of the problem if possible, repair it and then 
replace the damaged fuse with a new rated one.

 Fuse rating: 10 A

 

USE the applicable fuse only.

 Cleaning

If the transceiver becomes dusty or dirty, wipe it clean with a 
soft, dry cloth.

 DO NOT use harsh solvents such as benzine or 
alcohol, as they will damage the transceiver sur-
faces.

 Options

• OPC-1939/OPC-2078 

acc

 

cable

  Allows you to connect to an external terminal.

  OPC-1939: D-sub 15-pin, OPC-2078: D-sub 25-pin

 

NOTE: No Digital Modulation “IN” using accessory cables.

• 

HM-152/HM-152T/HM-148G 

hand

 

microphone

  HM-152  :  Hand microphone
  HM-152T : DTMF microphone
  HM-148G :  Self ground heavy duty microphone
• 

SM-26 

desktop

 

microphone

• 

SP-22/SP-30 

external

 

speaker

  Input impedance  : 4 

ø

  SP-22  : Rated input; 5 W, Max. input; 7 W
  SP-30  : Rated input; 20 W, Max. input; 30 W

Approved Icom optional equipment is designed for optimal perfor-
mance when used with an Icom transceiver.
Icom is not responsible for the destruction or damage to an Icom 
transceiver in the event the Icom transceiver is used with equipment 
that is not manufactured or approved by Icom. 

Содержание IC-F5122D

Страница 1: ...INSTRUCTION MANUAL UHF MOBILE TRANSCEIVER iF6122D VHF MOBILE TRANSCEIVER iF5122D...

Страница 2: ...ORD DEFINITION R WARNING Personal injury fire hazard or electric shock may occur CAUTION Equipment damage may occur NOTE If disregarded inconvenience only No risk of personal injury fire or electric s...

Страница 3: ...ose the transceiver to rain snow or any liquids USE the specified microphone only Other microphones have different pin assignments and may damage the trans ceiver DO NOT use or place the transceiver i...

Страница 4: ...the power 8 Channel selection 8 Call procedure 9 Receiving and transmitting 9 User Set mode 12 Encryption function 13 Emergency transmission 13 Stun function 14 Power OFF Emergency function 14 Priorit...

Страница 5: ...can be independently programmed by your dealer p 3 t MICROPHONE CONNECTOR Connect the supplied or optional microphone NEVER connect non specified microphones The pin assign ments may be different and...

Страница 6: ...Appears when a matching signal is received y ENCRYPTION ICON Appears when the encryption function is activated while operating in the digital mode u BELL ICON Appears blinks when a matching 2 5 tone o...

Страница 7: ...assigned to a Pri vate zone SCAN START STOPKEY Push to start and cancel scanning operation When a scan is started with the Power ON Scan or Automatic scan function push this key to cancel it The cance...

Страница 8: ...o grammed time period LIGHT KEY Push to turn ON the backlight for about 5 seconds when the backlight function is set to OFF in the User Set mode LOCK KEY Hold down this key until LOCK ON is displayed...

Страница 9: ...lection push this key again to set it TALK AROUND KEY Push to turn the Talk Around function ON or OFF The Talk Around function equalizes the transmit frequency to the receive frequency for transceiver...

Страница 10: ...curity alarm for example The siren can only be stopped by turning OFF the transceiver power TX CODE ENTER KEY PMR operation only Push to enter the TX code edit mode then push CH Up or CH Down to set a...

Страница 11: ...function Push this key again to enable the function Ext CH Sel Mode KEY Push to turn the Ext CH Select function ON or OFF When the function is turned ON memory channels can be selected with only and...

Страница 12: ...e input code number may be incorrect Turn OFF the power and re enter your password Channel selection There are several methods to select channels and they may differ depending on your system set up NO...

Страница 13: ...n ON the power w Push CH Up or CH Down to select a channel e When receiving a call rotate VOL to adjust the audio out put level to a comfortable listening level NOTE Depending on the preprogramming th...

Страница 14: ...tically sends the 5 tone DTMF BIIS or digital ANI ID code when PTT is pushed at the begin ning of the transmission and or when it is released at the end of transmission depending on the preprogramming...

Страница 15: ...tically blink y Repeat r and t to edit all allowable digits u After editing push TX Code CH Select to set Return to the stand by mode i Push Call to transmit USING TX CODE ENTER KEY q Push TX Code Ent...

Страница 16: ...econd to enter the User Set mode To exit the User Set mode hold down P0 for 1 second again P0 r Push P0 several times to select the appropriate item then push Up or Down to set the desired level or se...

Страница 17: ...LCD indication change IMPORTANT It is recommended to set an emergency channel individually to provide the certain emergency call operation D NOTES Depending on the preprogramming the following functio...

Страница 18: ...akes the transceiver transmit emergency calls even though it appears to be powered OFF To activate the Power OFF Emergency function turn the power OFF while holding down Power OFF Emergency When the f...

Страница 19: ...eaker e MICROPHONE HANGER Connect the supplied micro phone hanger to the vehicle s ground for microphone ON OFF hook functions See page 1 r OPTIONAL CABLE OPC 1939 OPC 2078 t t DC POWER RECEPTACLE Con...

Страница 20: ...ace which can support more than 1 5 kg Flat washer Felt Spring washer When using self tapping screws Felt reduces the effects of vibration Microphone Microphone hanger and screw set Microphone hanger...

Страница 21: ...ne or alcohol as they will damage the transceiver sur faces Options OPC 1939 OPC 2078 acc cable Allows you to connect to an external terminal OPC 1939 D sub 15 pin OPC 2078 D sub 25 pin NOTE No Digita...

Страница 22: ...G HR CZ CY DK EE FI FR DE GR HU IS IE IT LV 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 Liechtenstein Lithuania Luxembourg Malta Netherlands Norway Poland Portugal Romania Slovakia Slovenia Spain...

Страница 23: ...1 2 16 15 14 13 12 11 10 9 8 7 6 5 4 19 3 MEMO...

Страница 24: ...Osaka 547 0003 Japan Intended Country of Use AT FI IT PL GB RO BE FR LV PT IS TR CY DE LT SK LI HR CZ GR LU SI NO DK HU MT ES CH EE IE NL SE BG A 6906H 1EU qa Printed in Japan 2011 Icom Inc Printed on...

Страница 25: ...uite measurements have been performed This compliance is based on conformity with the following harmonised standards specifications or documents i ii iii iv v vi vii MAY 2011 EN 300 086 2 V1 3 1 2010...

Страница 26: ...able Essential Test Suite measurements have been performed This compliance is based on conformity with the following harmonised standards specifications or documents EN 300 086 2 V1 3 1 2010 06 EN 300...

Отзывы: