116
12
OTHER FUNCTIONS
■
Cloning function
The IC-E91 has transceiver-to-transceiver data cloning capa-
bility. This function is useful when you want to copy all of the
programmed contents from one IC-E91 to another.
• An optional OPC-474
CLONING CABLE
is required.
q
Turn the transceiver’s power OFF, then connect an op-
tional OPC-474 between both
[SP]
jacks.
w
While pushing
[MR]
and
[MENU/LOCK]
, push and hold
[PWR
] for 1 sec. to enter cloning mode.
• “CLONE M” appears.
e
Push
[PTT]
on the “master” transceiver.
• “CLONE OUT M” appears and the bar meter shows that cloning
is taking place.
• After the cloning is completed, the display returns to “CLONE M.”
r
Push and hold
[PWR]
for 1 sec. to turn power OFF.
The optional RS-91
REMOTE CONTROL SOFTWARE
is also
available to clone/edit contents with a PC (for Microsoft
®
Win-
dows
®
98/98SE/ME/2000XP) and using ICF format files.
Microsoft
®
and Windows
®
are registered trademarks of Microsoft Corporation in
the U.S.A. and other countries.
OPC-474
to the [SP] jack
to the [SP] jack