COMPONENTS 

 

 

 

 
 
 
 

 
 
 
 
 
 
 
 

 

 

 1. 

Safety valve for solar energy systems Art.S120 G1/2”F – G1/2”F 

 2. 

Instrument holder connection with manometer 0-6 o 0-10 bar 

 3. 

Taps for filling, emptying and washing the system  

 4. 

On/off valve with built-in thermometer and return connection with Anti-gravity non return valve

 

 5. 

Wilo Solar ST20/6 o Grundfos Solar 15-65 circulation pump 

 6. 

Flow controller with on/off valve, return connection 

 7. 

On/off valve with built-in thermometer and delivery connection  

 8. 

Air bleeding device 

 9. 

Preformed insulating base 

 10.  Hose connection 
 11.  Preformed insulating cover 
 12.   Inspection compartment insert 
 13.  Molex connector 
 14.  Cable duct groove 

 

DIMENSIONS 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Code  A 

B C D E F G H  I  L 

Weight 

(Kg) 

S001  G 

¾” 

M  100 140 325 480 420 260  60  60

 

170

7.0 

S002  G 

¾” 

M  /  140 275 480 420 235  40  60

 

170

5.0 

Tab.2 

Art.S002

Tab.1 

Art.S002

Art.S001 

Art.S001 

Содержание S001

Страница 1: ...95 C 0 3 bar 110 C 1 bar Min pressure for opening on off and check valve p 2Kpa 200 mm c a Safety valve Calibration of safety valve 6 bar Safety valve temperature range 30 160 C Connections of safety...

Страница 2: ...urn connection with Anti gravity non return valve 5 Wilo Solar ST20 6 o Grundfos Solar 15 65 circulation pump 6 Flow controller with on off valve return connection 7 On off valve with built in thermom...

Страница 3: ...4 08 about art S301 and S302 FILLING THE SYSTEM 1 Open the on off valve connected with the air bleed valve A Fig 1 located at the highest point of the system 2 Open the on off and check valves turning...

Страница 4: ...point in the system A Fig 1 and in the air separator 8 in Tab 1 When you have finished bleeding air check the pressure in the system and restore the desired operating pressure if necessary EMPTYING TH...

Страница 5: ...ng the rate of flow of fluid circulating in the system The flow meter has a rate of flow limiter which may be adjusted manually with a screwdriver Fig 4 A rate of flow indicator present inside the mea...

Страница 6: ...ses are separated from the head conveying fluid and accumulate in the upper part of the deaerator During start up accumulated gases must be evacuated periodically during the day using the manual air b...

Страница 7: ...rised personnel familiar with the instructions contained herein Make sure the system is shut down before performing any work on it ELECTRICAL CONNECTIONS Electrical connections must be made by qualifi...

Страница 8: ...ICMA s p a via Garavaglia 4 20012 Cuggiono MI ITALY Tel 39 02 97249134 39 02 97249135 Fax 39 02 97241550 www icmaspa it e mail sales icmaspa it pag 8...

Отзывы: