background image

To Remove Existing Thermostat

ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by removing the fuse 

or switching the appropriate circuit breaker to the OFF position before removing the existing 
thermostat.

1.  Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate 

circuit breaker.

2.  Remove cover of old thermostat. This should expose the wires.
3.  Label the existing wires with the enclosed wire labels before removing wires.
4.  After labeling wires, remove wires from wire terminals.
5.  Remove existing thermostat base from wall.
6.  Refer to the following section for instructions on how to install this thermostat.

ELECTRICAL SHOCK HAZARD

 – Turn off power at the main service panel by removing the fuse 

or switching the appropriate circuit breaker to the OFF position before removing the existing 
thermostat.

 

IMPORTANT:

 Thermostat installation must conform to local and national building and electrical 

codes and ordinances. 

 

Note:

 

Mount the thermostat about five feet above the floor. Do not mount the thermostat on an 
outside wall, in direct sunlight, behind a door, or in an area affected by a vent or duct.

1.  Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate 

circuit breaker. Move the 

Cool/OFF/Heat

 switch to 

OFF

.

To Install Thermostat

Содержание SC2000L

Страница 1: ...s troubleshooting tips and more visit us at www icmcontrols com SC2000 SC2001 Non Programmable Electronic Thermostats Controls Single Stage Heating Cooling Systems Single Stage Heat Pump Systems Compa...

Страница 2: ...Install Thermostat 4 Installing and Changing Batteries 6 Replacing Wiring Labels 6 SC2000 Wiring Diagrams 7 10 SC2001 Wiring Diagrams 11 13 A Quick Test 14 Operation 15 Troubleshooting 16 CAUTION This...

Страница 3: ...GAS ELEC SC2001 G O B Y RH RC W RH RC NON HP HP SC2000 GAS ELEC Reset Switch Electric Gas Jumper Mode Switch Fan Switch Freeze Switch High Temp Switch Non HP HP Jumper Electric Gas Jumper Mode Switch...

Страница 4: ...ery signal Temperature differential setting Room temperature Room temperature setpoint Always turn off the thermostat before installing removing cleaning or servicing turn off the power at the main po...

Страница 5: ...stems heating cooling systems and heat pump systems works with gas oil or electric systems Compatible as a master thermostat in zoned system applications Freeze Protection Feature Protects pipes from...

Страница 6: ...at base from wall 6 Refer to the following section for instructions on how to install this thermostat ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching...

Страница 7: ...ap supplied anchors into mounting holes 9 Align thermostat base with mounting holes and feed the control wires through wire opening 10 Use supplied screws to mount thermostat base to wall CAUTION Be s...

Страница 8: ...the battery compartment Proper battery installation is important Make sure the positive ends of the batteries match the positive terminals in the battery compartment If the display is on the batterie...

Страница 9: ...m RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G Zone 1 Zone 3 Zone 2 Zone 1 Zone 3 Zone 2 24 VAC 24 VAC Use appropriate size single pole double throw...

Страница 10: ...ntrol Fan Control T H E R M O S T A T RH RC W Y B O G HOT RH RC W Y B O G 120 VAC 24 VAC Remove Pre Installed Jumper Heating Control Cooling Control Fan Control Heating Transformer Cooling Transformer...

Страница 11: ...AC Transformer Heating Control Fan Control T H E R M O S T A T RH RC W Y B O G Heating Control T H E R M O S T A T RH RC W Y B O G Thermopile or Transformer 2 Wire Single Transformer or Millivolt SC20...

Страница 12: ...alve Compressor Contactor Fan Relay Reversing Valve Cooling Control Fan Control Cool Active Reversing Valve Heat Active Reversing Valve 3 Wire Single Transformer Note Place jumper between W and Y term...

Страница 13: ...11 4 or 5 Wire Single Transformer 24 VAC T H E R M O S T A T R C Y G 120 VAC HOT Transformer Fan Control W B O Heating Control Optional Cooling Control SC2001 Wiring Diagrams Heating and Cooling...

Страница 14: ...rmer 24 VAC T H E R M O S T A T R C Y G 120 VAC HOT Transformer Fan Control W B O Heating Control 3 Wire Single Transformer 24 VAC T H E R M O S T A T R C Y G 120 VAC HOT Transformer W B O Heating Con...

Страница 15: ...lay Fan Relay Fan Control Cooling Control Compressor Contactor Reversing Valve Compressor Contactor Reversing Valve Heat Active Reversing Valve Cool Active Reversing Valve 4 Wire Single Transformer He...

Страница 16: ...ay Action Set the Cool Off Heat switch to Heat Press the button until the temperature setting is 3 F above the room temperature Result The heating system and fan should turn on There may be a time del...

Страница 17: ...1 F the thermostat turns your system on If you notice your system turning on and off too frequently increase the temperature differential Step 1 Remove cover Insert a coin or screwdriver in slot at t...

Страница 18: ...Page 6 SC2001 Verify 24 VAC is at thermostat Thermostat is not properly controlling the fan Check that the Gas Electric jumper setting matches your system gas or electric Thermostat is continuously tu...

Страница 19: ......

Страница 20: ...er to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller promptly of any claim submitting date code information or any other pertinent data as requested by the S...

Отзывы: