background image

Important Safety Information

Input: 

  Input:

 

• 

Voltage:

 Millivolt to 30 VAC/VDC 

  • 

Voltage:

 18-30 VAC 

• 

DC Power:

 3 volts (2 “AA” alkaline batteries included)

Output:

 

• 

Maximum:

 1 amp per terminal (3 amp total for all terminals) 

• 

Temperature control ranges: 

45°F to 90°F   

Accuracy:

 ± 1°F

• 

Differential range: 

1°F to 3°F

• 

System configurations:

  Single-stage heat, single-stage cool 

or single-stage heat pump, gas, oil, 
electric

• 

Terminations (SC2000):

 RC, RH, W, Y, O, B, G

• 

Terminations (SC2001):

 R, W, Y, O, B, G, C

SET
ROOM
LO BAT
DIFF

Low battery signal
Temperature 

differential setting

Room temperature

Room temperature 

setpoint

• Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at 

the main power source by unscrewing fuse or switching off circuit breaker 

• Do not switch to “Cool” if room temperature is below 50°F; this could damage your A/C system and 

cause injury 

• Do not install on voltages higher that 30 VAC
• All wiring must conform to local and national building and electrical codes and ordinances
• While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth 

with a mild soap to wipe outside of thermostat cover 

Specifications

SC2000

SC2001

Содержание SC2000L

Страница 1: ...s troubleshooting tips and more visit us at www icmcontrols com SC2000 SC2001 Non Programmable Electronic Thermostats Controls Single Stage Heating Cooling Systems Single Stage Heat Pump Systems Compa...

Страница 2: ...Install Thermostat 4 Installing and Changing Batteries 6 Replacing Wiring Labels 6 SC2000 Wiring Diagrams 7 10 SC2001 Wiring Diagrams 11 13 A Quick Test 14 Operation 15 Troubleshooting 16 CAUTION This...

Страница 3: ...GAS ELEC SC2001 G O B Y RH RC W RH RC NON HP HP SC2000 GAS ELEC Reset Switch Electric Gas Jumper Mode Switch Fan Switch Freeze Switch High Temp Switch Non HP HP Jumper Electric Gas Jumper Mode Switch...

Страница 4: ...ery signal Temperature differential setting Room temperature Room temperature setpoint Always turn off the thermostat before installing removing cleaning or servicing turn off the power at the main po...

Страница 5: ...stems heating cooling systems and heat pump systems works with gas oil or electric systems Compatible as a master thermostat in zoned system applications Freeze Protection Feature Protects pipes from...

Страница 6: ...at base from wall 6 Refer to the following section for instructions on how to install this thermostat ELECTRICAL SHOCK HAZARD Turn off power at the main service panel by removing the fuse or switching...

Страница 7: ...ap supplied anchors into mounting holes 9 Align thermostat base with mounting holes and feed the control wires through wire opening 10 Use supplied screws to mount thermostat base to wall CAUTION Be s...

Страница 8: ...the battery compartment Proper battery installation is important Make sure the positive ends of the batteries match the positive terminals in the battery compartment If the display is on the batterie...

Страница 9: ...m RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G RH RC W Y B O G Zone 1 Zone 3 Zone 2 Zone 1 Zone 3 Zone 2 24 VAC 24 VAC Use appropriate size single pole double throw...

Страница 10: ...ntrol Fan Control T H E R M O S T A T RH RC W Y B O G HOT RH RC W Y B O G 120 VAC 24 VAC Remove Pre Installed Jumper Heating Control Cooling Control Fan Control Heating Transformer Cooling Transformer...

Страница 11: ...AC Transformer Heating Control Fan Control T H E R M O S T A T RH RC W Y B O G Heating Control T H E R M O S T A T RH RC W Y B O G Thermopile or Transformer 2 Wire Single Transformer or Millivolt SC20...

Страница 12: ...alve Compressor Contactor Fan Relay Reversing Valve Cooling Control Fan Control Cool Active Reversing Valve Heat Active Reversing Valve 3 Wire Single Transformer Note Place jumper between W and Y term...

Страница 13: ...11 4 or 5 Wire Single Transformer 24 VAC T H E R M O S T A T R C Y G 120 VAC HOT Transformer Fan Control W B O Heating Control Optional Cooling Control SC2001 Wiring Diagrams Heating and Cooling...

Страница 14: ...rmer 24 VAC T H E R M O S T A T R C Y G 120 VAC HOT Transformer Fan Control W B O Heating Control 3 Wire Single Transformer 24 VAC T H E R M O S T A T R C Y G 120 VAC HOT Transformer W B O Heating Con...

Страница 15: ...lay Fan Relay Fan Control Cooling Control Compressor Contactor Reversing Valve Compressor Contactor Reversing Valve Heat Active Reversing Valve Cool Active Reversing Valve 4 Wire Single Transformer He...

Страница 16: ...ay Action Set the Cool Off Heat switch to Heat Press the button until the temperature setting is 3 F above the room temperature Result The heating system and fan should turn on There may be a time del...

Страница 17: ...1 F the thermostat turns your system on If you notice your system turning on and off too frequently increase the temperature differential Step 1 Remove cover Insert a coin or screwdriver in slot at t...

Страница 18: ...Page 6 SC2001 Verify 24 VAC is at thermostat Thermostat is not properly controlling the fan Check that the Gas Electric jumper setting matches your system gas or electric Thermostat is continuously tu...

Страница 19: ......

Страница 20: ...er to permit the Seller to properly administer the warranty the Buyer shall 1 Notify the Seller promptly of any claim submitting date code information or any other pertinent data as requested by the S...