If your LCD is blank, or displaying
LO BAT
, the batteries are not installed or need to be changed. We
suggest you change the batteries at least once a year, or whenever the
LO BAT
warning displays.
Note:
After installing new batteries, you have to reset the room temperature setting and the
differential setting.
Step 1:
Move the
Cool/Off/Heat
switch into the
Off
position.
Step 2:
Move the
Fan Auto/On
switch into the
Auto
position.
Step 3:
Remove the cover, and install the two “AA” alkaline batteries into the battery compartment.
Proper battery installation is important! Make sure the positive ends of the batteries match the
positive terminals in the battery compartment.
If the display is on, the batteries are installed properly.
Replace the old labels with the enclosed new labels:
Old
New
Type
R, V-VR or VR-R
RH
24 VAC, heat transformer
Y, Y1 or M
Y1
Stage 1 cooling
G or F
G
Fan contactor circuit
Y2
Y2
2nd stage cooling control
W1, W2 or W-U
W2
2nd stage heating control
C, X or B
C
24 VAC, transformer common side
W1
W1
Stage 1 heating
RC
24 VAC, cool transformer
Installing and Changing Batteries
Replacing Wiring Labels
Содержание SC 2300