9.
Status Indicator Light
(Lt 0 or 1)
0 = Status indicator never on
1 = Status indicator on with first stage
Press the or button to select.
Note:
Red light indicates heating cycle and green light indicates cooling cycle
Slide the
Mode
switch to
Heat
or
Cool
to exit configuration.
8.
Filter Check time
(300-800, – – –)
Set
Fan Run Time
(in hours) when
Check Filter
is displayed or set to – – – to disable.
Press the or button to select.
Note:
To reset filter counter to zero and clear filter warning, press the and
buttons simultaneously for 5 seconds.
Press the
SW6
button to advance to the next screen.
7.
Maximum heating or cooling cycles allowed per hour
(-, 2-6)
- = as many as needed, 2-6 = maximum cycles/hour
Press the or button to select.
Press the
SW6
button to advance to the next screen.
FILTER
SET
ROOM
SET
SET
SET
6.
Room temperature offset
(+9°F to -9°F) (+4.5°C to -4.5°C)
Adjust to calibrate displayed room temperature to match actual room temperature.
Note:
When not set to 0,
ROOM
will display
Press the or button to select.
Press the
SW6
button to advance to the next screen.