REPLENISHING C02 SUPPLY
1. Close empty C02 cylinder shutoff valve.
2. Disconnect high-pressure C02 regulator, then remove empty C02 cylinder
3. Install full C02 cylinder and connect high-pressure C02 regulator. See installation
procedure in CHAPTER II.
MAKE SURE C02 CYLINDER IS POSITIONED IN UPRIGHT POSITION AND
FASTENED WITH SAFETY CHAIN. ALWAYS OPEN C02 VALVE COMPLETELY OR
UNTIL BACK SEATED DURING OPERATION. WHEN BOTTLE IS EMPTY ALWAYS
CLOSE VALVE ASSEMBLY COMPLETELY.
REPLENISHING SYRUP SUPPLY
1. Remove Q.C.D.s from empty B.I.B. or syrup & C02 quick disconnects from empty
syrup tank.
2. Install full syrup container in position, rinse Q.C.D.s or quick disconnects in warm
water, then connect Q.C.D.s or syrup & C02 quick disconnects to tank.
3. Activate valve until syrup flows from valve normally. See CHAPTER II.
SYRUP FLAVOR CHANGE
1. Remove Q.C.D.s from applicable B.I.B. or syrup quick disconnects from applicable
syrup tank.
2. Sanitize applicable syrup system in accordance with instructions. See paragraph
CLEANING AND SANITIZING in this chapter.
3. Install full syrup container in position, rinse Q.C.D.s or quick disconnects in warm
water, then connect Q.C.D.s or syrup & C02 quick disconnects to container.
4. Activate valve until syrup flows from valve normally. See CHAPTER II.
CHANGING WATER FILTER CARTRIDGE
Follow manufacturer's instructions for water filter.
ADJUSTMENTS
HIGH-PRESSURE C02 REGULATOR
The high-pressure C02 regulator will have two gauges that extend above and to the side
of the bell housing screw area. The P.S.I. gauge will show graduated indications up to
3000 psi and be the gauge the farthest from the C02 cylinder connection. This gauge will
normally have a Red area indicating 500 psi to 0 psi. This gauge will be used to check
volume of liquid in the C02 cylinder. The other gauge will show regulated pressure that
will be delivered to the TOPPER carbonation system. This gauge can be indicated from
0-160 psi up to 0-300 psi. By turning the high-pressure regulator adjustment screw
clockwise we will increase pressure supplied to our carbonator which will be indicated on
this gauge. To lower pressure to carbonation system it is recommended that the
adjustment screw be turned counter clockwise several full turns and then the relief valve,
(S-215), be lifted lowering pressure in carbonating system, now readjust. When adjusting
C02 high-pressure regulator a setting of 70-75 psi is recommended.
5-7