-8-
iCharger Synchronous Balance Charger/Discharger 3010B
Keyboard basics
1. Go to the main menu, press the
Inc
button or the
Stop/Batt type
button
to go down, and press the
Dec
button to go up: press the
Start/Enter
button to enter a sub-menu.
2. In a sub-menu, press
Start/Enter
to blink the chosen item, and then alter the value with
Inc
or
Dec.
With nothing blinking you can go to the sub-menu below with
Inc
and above with
Dec
. Press
Stop/Batt type
to go back to the previous screen.
3. In some sub-menus, press and hold
Start/Enter
for more than 3 seconds to start the process, such as
starting charging or discharging.
4. During the charging/discharging process you can terminate the process at any time by pressing
Stop/Batt type
and check the attached information with
Inc
or
Dec
. Press
Start/Enter
to go back to
the main information screen.
5. During the discharge process, press
Start/Enter
to alter the discharge current. When the discharge
current blinks, press
Inc
to increase it or
Dec
to decrease it, then press
Start/Enter
to confirm the
change.
6. Press
Stop/Batt type
for more than 3 seconds to start the display of the active test information as per
the following diagram.
Present testing information
:
7.
Reset to Defaults
function. Press
Stop/Batt type
and
Start/En
ter
together for more than 3 seconds to
obtain this display:
8. Adjust Current, Temp. Cut-Off, Safety timer, Capacity Cut-Off in course of charging and discharging.
Method of Application:
When in charging and discharging interface, press
Start/Enter
for 3 seconds, and current begins
blinking.
Press
Inc
or
Dec
to adjust current, and press
Start/Enter
to save changes. If users press
Stop/Batt
type
or without any operation for 1 minute, it will cancel and quit from the changes.
Note
: Adjustment of current is only effective for charging and discharging, which will not saved as user
setting.
When in charging and discharging interface, press
Dec
for several times to see need-to-be changed
information interface. Press
Start/Enter
for 3 seconds, and the value begins blinking. The adjust method
is as same as the above.
Note
: This change can be saved as user setting.
Resume defaults?
CONFIRM (ENTER)
Vi11.94V Int30℃
Vo 8.23V Ext25℃
Output
Volt.
Input
Volt.
Int.
Temp.
Ext.
Temp.
Inc
1:4.11 4.12 ----
4:---- ---- ----
7:---- ---- ----
A:----
Inc
1: 21 24 m
Ω
4: m
Ω
Dec
Battery Pack IR
45m
Ω
Dec
In this display the output voltage is the idle voltage measured at the
output terminals (that is, the voltage of the connected battery pack).
Individual cell voltage from
the balance port.
Per cell resistance from
the balance port.
Stop/Batt type
>3 seconds
Pressing
Start
for 3 seconds to monitor the resistance again.
Press
Start/Enter
to reset all values to the system-default settings.
Pack cells resistance from
the balance port.