[ 9 - 7 ] " L O W "
[ 9 - 7 ] " L O W "
[ 9 - 8 ] H e a t i n g
[ 9 - 8 ] H e a t i n g
[ 9 - 9 ] H e a t i n g
[ 9 - 9 ] H e a t i n g
F u n c t i o n
F u n c t i o n
a f t e r R e f r i . H o t g a s
3 . D r a w a f t e r : 2 m i n
4 . B r e a k T i m e : 1 m i n
5 . H i g h s p e e d : 1 0 s e c
6 . S e t C u r r e n t : 0 . 2 A
1 . W o r k i n g ? : O n
2 . O p e n T i m e : 5 0 s e c
a f t e r R e f r i . H o t g a s
3 . C l o s e T i m e : 0 s e c
a f t e r F r e e z e r H o t g a s
3 . C l o s e T i m e : 3 0 s e c
4 . A p p l y T i m e : 1 2 0 s e c
9-7-4: Rest time setting when LOW appears
When LOW appears, the rest time set at this category is
applied instead of the rest time set at category ‘
4-1
’ .
9-7-5: High speed rotation time setting when LOW appears
When LOW appears, it sets the time for high speed
rotation after the rest time of the category ‘
9-7-4
’ .
9-7-6: Set up the reference current for deciding
‘LOW’ in resale
Set up the reference current for deciding ‘LOW’ in resale
9-7-3: Set up the time criteria for deciding ‘ LOW’
in resale Set up the reference time for deciding
‘ LOW’ in resale
9-8-2: Hot gas valve operation time
It sets the operation time of hot gas valve during the
refrigeration of hopper after pasteurization.
9-8-3: Hot gas valve rest time
It sets the rest time of hot gas valve during the
refrigeration of hopper after pasteurization.
9-8/9-8-1:Cold storage preferred refrigeration set up after pasteurization
It selects the use of hot gas valve during standby after
pasteurizationIt is applied to the refrigeration of hopper
after pasteurization, and refrigeration valve works
even when this category is not activated.
9-9/9-9-1: Freezing preferred refrigeration set up after pasteurization
Selection of hot gas valve use during standby after
pasteurizationIt is applied to the refrigeration of the
cylinder after pasteurization.
Refrigeration valve works even when this category is not
activated.
9-9-2: Initial Hot gas valve operation time
It sets the operation time of hot gas valve during the refrigeration of cylinder after pasteurization.
9-9-3: Initial Hot gas valve rest time
It sets the rest time of hot gas valve during the
refrigeration of cylinder after pasteurization.
1. ‘LOW
’
message appears when soft freezer does not reach the set current.
It happens when the blade does not clean theinner wall of the cylinder, the raw material
is not supplied from the hopper or there are problems in refrigeration capacity.
2. Categories
‘
9-7-4
’
and
‘
9-7-5
’
are activated in the models with inverter.
However, this function is repeated 2 or 3 times before normal operation.
9-9-4: Initial hot gas valve cycle operating time set up
Set up the time applied to the cycle operation of ‘9-9-2’ and ‘9-9-3’.
Explanation of the function buttons(set by a user)
important
a f t e r F r e e z e r H o t g a s
1 . W o r k i n g ? : O n
2 . O p e n T i m e : 1 0 s e c