12

 Name of each part

Front view

COVER BASKET

WATER

VALVE

LCD 

WINDOW

CONTROL 

BUTTON

SELECT 

BUTTON

PUSH 

BUTTON

WASH BUTTON

TOP COVER

POWER SWITCH

DASHER COVER

DASHER COVER 

BOLT

CUP SENSOR

FEEDER

DRAIN BOX

FOOT

CONDENSER FILTER

INSIDE:  CONDENSER   

              FILTER

ISI-271SHS 

ISI-271THS 

LOCK

RAW STORES

LOCK

920

380

1400

380

Содержание ISI-271THS

Страница 1: ...ELF MACHINE User s Manual ISI 271THS ISI 271SHS This product is designed for indoor use Make sure to install it indoors The appearance design color and parts of the product are subject to change witho...

Страница 2: ...e pasteurization process is implemented for heating products at 68 C for 30 minutes to supply sanitary ice cream products sans the spoilage of materials The soft ice cream inside the cylinder can be d...

Страница 3: ...f each part 11 14 Product specification 15 Check prior to use 16 Button display names and functions 17 Functional description of the buttons 18 22 Explanation of the function button 23 42 3 category 2...

Страница 4: ...This means that it can cause death or major injury when the details are violated If you neglect this symbol and wrongly use the product it may cause a fire serious injury or death Warning Danger Caut...

Страница 5: ...nt may result unless it is properly disposed of Call your distributor Caution Caution If the power cable needs replacement or repair call a service center or an expert Caution Do not place any obstacl...

Страница 6: ...not operate the product while all panels are not well fastened enough Caution Caution Caution Caution Caution Caution While operating the product please close the upper cap completely Do not arbitrar...

Страница 7: ...em Prohibited If the supply cord is damaged it must be replaced by the manufacture its service agent or similarly qualitied persons in order to avoid a harzard Fire or electric shock may occur Oh NO P...

Страница 8: ...ss Prohibited Do not disassemble or alter the product Electric shock fire or injury may occur Prohibited Do not touch the power cable or any elctric part with wet hands Explosion fire or injury may oc...

Страница 9: ...upply hose should be used which is on condition that IEC 61770 and EN 50084 are satisfied This appliance is not intended for use by persons including children with reduced physical sensory or mental c...

Страница 10: ...cking taking care not to damage the exterior of the Soft Ice Cream Self Machine 2 Remove the wooden packaging and the protective tapes and make sure that all parts of the system are complete When tilt...

Страница 11: ...rugated tube nut of the feed water line and join it to the water inlet of the product Tighten the nut firmly with a tool 2 Pay special attention to protecting Section A from damage when assembling the...

Страница 12: ...VE LCD WINDOW CONTROL BUTTON SELECT BUTTON PUSH BUTTON WASH BUTTON TOP COVER POWER SWITCH DASHER COVER DASHER COVER BOLT CUP SENSOR FEEDER DRAIN BOX FOOT CONDENSER FILTER INSIDE CONDENSER FILTER ISI 2...

Страница 13: ...COVER UP INSIDE CONTROL BOX FEEDER ROAD Note For buyer request it can be movable designed Caster or leg SIDE PANEL L FEEDER COVER DRAIN SLUG SIDE LUVER L FEEDER COVER SIDE PANEL R CASTER ISI 271SHS I...

Страница 14: ...14 Name of each part Back view INSIDE COMP BACK PANEL Feedwater section Power supply INSIDE INVERTER Remote control switch connector ISI 271SHS ISI 271THS INSIDE SMPS...

Страница 15: ...RUM BRUSH CARBURETOR OUT HANDLE JOINT BOLT CABURATOR PACKING SHAFT POM PACKING PACKING DASHER COVER DASHER LUG FRONT WHITE DASHER LUG BACK WHITE HINES MANUAL 1EA 1EA 1EA 1EA 1EA 1EA 1EA CABURATOR TUBE...

Страница 16: ...Number of dispensed cups without interval 40 cups Under conditions of ambient temperature of 27 C and ice cream weight of 80 grams Cooling temperature Can keep under 5 Condenser Fully sealed compresso...

Страница 17: ...e of soft ice cream do not miss the filter cleaning time It is recommended to clean the cylinder the mixing tank the impeller the dasher the caburator the cup sensor the piston every day Clean the con...

Страница 18: ...elevant to sales Self service sale and remote sale may be selected by simultaneously pressing CHK and SELECT buttons Pressing this button once discharges a single cup and keeping this button pressed f...

Страница 19: ...me increases by 0 1 second Max Values of 3 8 2 or 3 10 2 of each mode The time remaining until the restarting of the compressor will be displayed in Min unit If the ambient temperature is high the com...

Страница 20: ...quid raw material It displays the present current value of the dasher motor Heat the raw material or water in the cylinder and the hopper to reach the set temperature in order to wash with hot water P...

Страница 21: ...then you should heat it at 68 70 for more than 30minutes every day After pasteurization This stage refrigerates the raw material in the hopper and cylinder cool Refrigeration process is applied to th...

Страница 22: ...n mode Press the SET button to see the setting values in the following order The temperature setting in the hopper and cylinder appear The rated voltage frequency and current of the freezer are displa...

Страница 23: ...t a l 1 2 0 1 2 0 9 2 2 I 5 I 5 S u c c e s s Press the SELECT button for three seconds to check the records in the order of Sterilization Washing and Error as shown in the right Display items can be...

Страница 24: ...per cooling temperature This item is used to adjust the cooling temperature of the ingredientsinthehopper Thelargerthenumberis thehigherthe storage temperature is The smaller the number is the lower t...

Страница 25: ...for cup ring cup holder to stay when it stops after the time set in 3 8 3 When this period elapses the cup holder automatically descends 3 8 5 Set the time to open the piston by operating the piston m...

Страница 26: ...der to stay above Explanation of the function button 3 10 I n i t i a l S a l e 3 10 I n i t i a l S a l e 3 10 I n i t i a l S a l e 3 10 I n i t i a l S a l e 3 10 I n i t i a l S a l e 3 10 I n i t...

Страница 27: ...T button to move to the next digit Inputthe4digitpasswordinthisway Do not let anyone without professional education know the 4 digit password under any circumstances Only experts that have been design...

Страница 28: ...4 3 O p e r a t e T e m p H o p p e r A U T O S T A N D B Y 4 3 Hopper management temperature setting This sets the management temperature to refrigerate the raw material in the hopper The temperature...

Страница 29: ...function to pasteurize the raw material and the soft icecream in the hopper and the cylinder The model with the pasteurization function is on and the model without the pasteurization function is off F...

Страница 30: ...pasteurization start time setting This sets the time to start auto pasteurization Minutes are set in this category 4 9 11 Auto set after pasteurization Select whether to execute auto when stand by has...

Страница 31: ...L e f t 1 P o w e r C h e c k O n 2 V o l t a g e 2 2 0 V 3 H e r t z 6 0 H z 4 13 4 13 1 Supply power standard value setting Set the voltage and frequency standard of supply power When this function...

Страница 32: ...t time In case 4min is chosen it means detecting temperature 4minutes after rest It sets the temperature for operating the compressor The compressor is operated when the temperature reaches the temper...

Страница 33: ...ry The time for this category means the minimum time necessary to clean the parts inside the cylinder such as the dasher the blade and so forth 4 24 4 No wash warning date setting An alarm Voice Suppo...

Страница 34: ...This sets the temperature compensation value of the hopper to the environmental temperature of 10 or lower 4 26 2 Temperature compensation value setting for 20 or lower This sets the temperature compe...

Страница 35: ...igerants inside the cylinder from rising above this value set at this category 4 29 4 Management time setting during water boiling It sets the time necessary to maintain the management temperature of...

Страница 36: ...selection It selects the function to set standby automatically when dispenser error Er27 Er28 Er29 Er30 Er33 Er34 appears 4 33 3 First auto recycling limit time setting Set up the time while auto rege...

Страница 37: ...ategory is passed 4 37 5 Reset function selection This category selects reset function when abnormal operations excessive current TP on peration inverter trouble and so forth occur in the motor 4 36 A...

Страница 38: ...this category as STAN and execute auto stand by 4 38 2 Selection of auto Standby Choose ON for auto Standby and choose OFF for no auto Standby When ON is selected the following categories are activat...

Страница 39: ...valve operation mode effective storage of ingredient can be done Either At the operation of either the freezing valve or refrigeration valve the compressor starts to operate Drum on Only when the fre...

Страница 40: ...rminated 9 4 9 4 1 Refrigeration valve operation selection Apply during refrigeration after It selects the use of operation time of refrigeration valve that refrigerate the raw material in the hopper...

Страница 41: ...of 2 4 may display error 9 5 3 Refrigerants detection management temperature When temperature reaches the reduced temperature by the value set at these categories 9 5 2 9 5 3 after the compressor sto...

Страница 42: ...8 1 Coldstoragepreferredrefrigerationsetupafterpasteurization It selects the use of hot gas valve during standby after pasteurizationIt is applied to the refrigeration of hopper after pasteurization a...

Страница 43: ...9 4 9 12 Compressor operation judgment current In case of typical ON OFF in auto mode it sets the current value ofthe motor that is needed to operate the compressor When the present current is lower...

Страница 44: ...on stage set the frequency of the inverter to run the dasher motor for the stage after the start of the ice cream production 9 17 3 Adjust dasher motor speed at dispensing The inverter which runs the...

Страница 45: ...ss of LCD BACK LIGHT Adjust the LCD BACK LIGHT time Kept lighted if set up as FULL ON 9 19 1 Set up password Set up the password required for administrator mode Item No4 9 19 2 Set up use or not of ad...

Страница 46: ...m n A m o u n t Initializing the amount displays the message as shown in the figure 1 1 Resetting the sales amount per column upon setting to one time Items 1 2 only applicable to manual machine Items...

Страница 47: ...the total sales quantity for cash per column 1 3 T o t a l C a s h S u m C o l 1 C o l 2 C o l 3 R e s e t N O 1 3 T o t a l C a s h S u m Itisallowedtoinitializethesalesamountfor cashmadesofar press...

Страница 48: ...the total sales quantity for cash per column 1 5 T o t a l C a r d S u m C o l 1 C o l 2 C o l 3 R e s e t N O 1 5 T o t a l C a r d S u m It is allowed to initialize the sales amount made for cardso...

Страница 49: ...o be conducted while setting the value to 1 automatically returns change Sale related Settings It is allowed to verify the sales quantity for testing per column Pressing the CHK button for five second...

Страница 50: ...l value display window place a cup on the conveyor device The indicator then blinks Pressing the Sale button initiates self service sale of the product takes about 15 seconds to complete 5 For remote...

Страница 51: ...rilization The lease raw materials shall be kept in the storage tank during sterilization and materials shall smoothly be agitated by the impeller The 12 liter storage tank shall be filled with materi...

Страница 52: ...ter that it willautomatically enter into Auto mode The regeneration time depends on the surrounding environment and cleaning 3 Open the caburator hole PASTEURIZE PASTEURIZE REGENERATION BOILING If you...

Страница 53: ...he protrusion of the upper area of the caburator body with the large hole in the upper area of the tube Decrease the overrun and increase the amount of ingredients injection in this way when you need...

Страница 54: ...hall be cleaned every 14 days as shown in the figure The carburetor impeller and ice cream discharge port shall be cleaned once a day Caution PASTEURIZE PASTEURIZE REGENERATION BOILING PASTEURIZE PAST...

Страница 55: ...ean the inside of the piston furrow with a brush and remove any remaining moisture with a soft towel 6 Stop the product by pressing stop button donotturnoffthepowerswitch and loose the dasher cover bo...

Страница 56: ...he front door of the product 2 Shake off filter dusts and wash it off thoroughly with water After washing it Dry the filter 3 The condenser surface has lots of dust Remove it by using a small brush 4...

Страница 57: ...t the mixing shaft into it 2 Insert the packing dasher to the dasher cover packing dasher Direction check 3 In the assembled dasher the front part of the mixing shaft must be located like 3 Carefully...

Страница 58: ...he system 3 Insert the USB memory into the USB port of the USB Download PCB 4 Turn off the power switch on the front side of the system and then turn it on 5 Wait until the indicator of the USB Downlo...

Страница 59: ...USB downloader 1 5 Turn power to the self machine on 1 6 The red the green and the yellow LED s lights on the USB downloader 1 7 The red LED is extinguished the green LED extinguished and the yellow L...

Страница 60: ...LED s light on the USB downloader 2 5 The red LED is extinguished the green LED extinguished and the yellow LED lights on the USB downloader 2 6 The red LED blinks the green LED extinguished and the...

Страница 61: ...n 4 4 The red the green and the yellow LED s light on the USB downloader 4 5 The red LED is extinguished the green LED extinguished and the yellow LED s lights on the USB downloader 4 6 The red LED is...

Страница 62: ...name in dark characters to a hex file name to write Do not use special characters such as parenthesis comma and exclamation mark for file name 5 5 The procedures hereafter are identical with those in...

Страница 63: ...ile in the notepad shows as follows 6 4 Change the hex file name in dark characters to a hex file name to write Do not use special characters such as parenthesis comma and exclamation mark for file na...

Страница 64: ...file in the notepad shows as follows Change the hex file name in dark characters to a hex file name to write Do not use special characters such as parenthesis comma and exclamation mark for file name...

Страница 65: ...file name in blue characters to a hex file name to write Do not use special characters such as parenthesis comma and exclamation mark for file name 8 4 The procedures hereafter are identical with thos...

Страница 66: ...ted color in compound mode The LED lamp slowly turns on and off repeatedly Turning 6 on causes the LED indicator to blink in the selected color in compound mode the LED indicator turns on and off repe...

Страница 67: ...ic leak detector or soap bubbles to check for leaks Add a trace of refrigerant to the system if using an electronic leak detector and then raise the pressure using nitogen gas 140PSIG DO NOT use R 404...

Страница 68: ...of refrigerant to the system if using an electronic leak detector and using nitogen gas 140PSIG DO NOT use R 404A as a mixture with pressurized air for leak testing 1 When brazing copper pipe purge th...

Страница 69: ...vary depending on the capacity of the vacuum pump 4 Open the manifold valves on the high and low pressure ends 5 Remove the manifold hose from the vacuum pump and connect the hose to the refrigerant s...

Страница 70: ...isture 1 Turn off the power of ELCB 2 Open the side door 3 Recover the refrigerant using an adequate vessel 4 Remove the terminal cover of the compressor and disconnect the compressor cable 5 Remove t...

Страница 71: ...y using a wet cloth to provent the drier and 4 way valve from overheating Do not allow the drier to exceed 250 121 1 Turn off the power of ELCB 2 Open the side door 3 Recover the refrigerant using an...

Страница 72: ...y using a wet cloth to provent the and drier 4 way valve from overheating Do not allow the drier to exceed 250 121 1 Turn off the power of ELCB 2 Open the side door 3 Recover the refrigerant using an...

Страница 73: ...en the back panel cover 7 Remove the harness from the fan motor 8 Remove the four screws from the fan motor assembly 9 Remove the screws fastening the bracket that fixes the condenser total of 4 screw...

Страница 74: ...y valve 6 Remove the solenoid coil from the 4 way valve 1 bolt 7 Remove the 4 way valve four brazing points 8 While purging with nitrogen gas at pressure of 3 4 psig braze a new 4 way valve 9 Replace...

Страница 75: ...75 Wire diagram...

Страница 76: ...VE CHECK FAN PRESS S W CONDENSER COMPRESSOR 4WAY ACCUMULATOR FITER DRYER VALVE ASS Y HIGH PRESSUER CYLINDER ASS Y HOPPER ASS Y CAPILLARY SOLENOID VALVE TUBE CAPILLARY TUBE 1 2 3 4 5 VALVE CHECK HOT GA...

Страница 77: ...This is the sound of plastic blade dasher blade that cleans the wall of the cylinder while making soft ice cream Cup does not rise 1 Place a cup and press the push button for free supply 2 Press the...

Страница 78: ...can be bigger 2 This product controls the ejection amount of Soft ice cream by time Therefore the product is sensitive to the quality of the raw material the level of raw material in the hopper ice qu...

Страница 79: ...m contact A S Center Reset Stop Er12 Draw Switch Er Discharge lever error Lift the discharge lever Auto release operation Er13 Condensor OH Abnormal temperature of condenser Check the vent for cloggin...

Страница 80: ...or Close Er Door closing error Removing foreign material from doors After reset release Stop Er47 Coin Mechanism Coin unit error empty the coin After reset release Stop Er48 Bill Validator Bill unit e...

Страница 81: ...xternal impacts or falling 8 Natural disasters thunderbolt fire earthquake flooding tsunami etc 9 Due to the expiration of a consumable part Packing blade cleaning brush etc 10 Foreign substances in t...

Страница 82: ...MEMO 82...

Страница 83: ...MEMO 83...