[ 9 - 4 ] H e a t i n g
[ 9 - 5 ] S e n s i n g
[ 9 - 5 ] S e n s i n g
[ 9 - 7 ] " L O W "
a f t e r R e f r i . V a l v e
D i s c h a r g e T e m p
D i s c h a r g e T e m p
F u n c t i o n
3 . V a l v e C l o s e : 1 2 0 s e c
4 . V / V F u l l ON : Y E S
1 . W o r k i n g ? : O n
2 . C o n t r o l T e m p : 1 0 0 . 0 °C
3 . O p e r a t e T e m p : 1 0 . 0 °C
1 . D i s p l a y ? : O n
2 . I n i t i a l : 3 m i n
9-4-3: Refrigeration valve rest time setting
It sets the rest time of refrigeration valve that refrigerates
the raw material in the hopper.
Ice can be formed on the wall of the hopper when
the time of this category is too short, and the raw
material in the hopper may not be refrigerated when
the time of this category is too short.
9-4-4: Set up refrigeration valve
‘ Full OPEN’
Set up valve Full Open while refrigerating the raw
material in the hopper.
9-5/9-5-1: Refrigerants temperature use
Refrigerants temperature use can be set to ON/OFF.
This category needs to be activated first in order to
activate the category ‘
4-31
’.
When this category is activated and category
‘
4-31
’ is not activated, the refrigerants temperature
of ‘
2-4
’ may display error.
9-5-3: Refrigerants detection management temperature
When temperature reaches the reduced temperature
by the value set at these categories (9-5-2, 9-5-3)
after the compressor stopped at the value set at ‘
9-5-2
’ ,
the compressor is operated again.
9-5-2: Refrigerants detection control temperature
When
‘
9-5-1
’ is activated, the temperature of the refrigerants set at this category is checked.
If the temperature is hotter, the operation of the compressor is stopped.
9-7/9-7-1: ‘LOW’ output use setting
Soft ice cream reaches the set value after the machine
is operated. When it does not reach the controlled value due
to other reasons (lack of raw material supply and so forth),
LOW message is displayed.
This category decides output.
9-7-2: Initial ‘LOW’ output time
When operating the machine for the first time, if soft ice cream is not made 100% with in the
time set at this category from the moment of 0.2A(9-7-6) increase from no load current (1-2),
LOW is displayed.(ex L90%)
9-4-2: Refrigeration valve operation time setting
It sets the operation time of refrigeration valve that refrigerates the raw material in the hopper.
Be careful as ice can be formed on the wall of the hopper when the time of this category is
adjusted too much.