44
Error Codes and Corrective Actions
The soft ice cream freezer may malfunction due to incorrect operation procedure or a trivial cause other
than machine defect or failure. If the following corrective actions fail to correct the problem, or the error code
is not presented below, or the same error persists, contact the nearest After Service Center.
※ Before contacting the After Service Center, turn power off, wait for five minutes, then turn power on
and start the machine again.
Error code
Possible Cause
Corrective Action
Release
Action
Er00
Mix Out
Fall short of row material Refill row material in the
storage container
Auto release
Stop
Er01 Hop. Sensor Op.
Cooler sensor OPEN
Sensor failure(contact A/S Center)
Auto release
Stop
Er02
Hop. Sensor St.
Cooler sensor SHORT
Sensor failure(contact A/S Center)
Auto release
Stop
Er03
Cyl. Sensor Op.
Cooler sensor OPEN
Sensor failure(contact A/S Center)
Auto release
Stop
Er04
Cyl. Sensor St.
Cooler sensor SHORT
Sensor failure(contact A/S Center)
Auto release
Stop
Er05
Air. Sensor Op.
Condenser OPEN
Sensor failure(contact A/S Center)
Auto release
operation
Er06
Air. Sensor St.
Condenser SHORT
Sensor failure(contact A/S Center)
Auto release
operation
Er07
EOCR
Motor over current
detected
Melt the ice cream and
restart the machine
Reset
Reset operation
Er08
High Pressure
Over voltage detected Clean the filter unit,
check exhaust air line
Auto release
Stop
Er09
noLA
Product immature yet
Refrigerant problem
(contact A/S Center)
Auto release
operation
Er10
Low Voltage
Supply voltage
exceeded by -15 %
Power supply problem
(contact A/S Center)
Auto release
Stop
Er11
High Voltage
Supply voltage
exceeded by +15 %
Power supply problem
(contact A/S Center)
Reset
Stop
Er12
Draw Switch Er.
Discharge lever error
Lift the discharge lever .
Auto release
operation
Er13
Condensor OH
Abnormal temperature of
condenser
Check the vent for clogging.
Auto release
operation
Er14
Motor Belt Er.
Defective drive shaft
Melt the ice cream and
restart the machine
Reset
Reset operation
Er15
EEPROM Error
EEPROM fault
pcb fault(contact A/S Center)
Reset
operation
Er16
Reverse Phase
Reverse phase sensing Power supply problem
(contact A/S Center)
Auto release
Stop
Er17
Heating Error
Defective sterilization
function
Replace the ice cream row
material and clean the machine
Other
operation
operation
Er18
Cover Error
Defective dasher cover Mount the dasher cover
at correct position
Auto release
Stop
Er19 Eva. Sensor Op.
Eva. Sensor OPEN
Sensor failure(contact A/S Center)
Auto release
operation
Er20
Eva. Sensor St.
Eva. Sensor SHORT
Sensor failure(contact A/S Center)
Auto release
operation
Er21
Motor Power Er.
Failed to detect electric
motor current
Machine failure
(contact A/S Center)
After reset
release
Reset operation
Er22
Power Fail Er.
Power turned off
Taking place in blackout
(no corrective action)
Auto release
operation
Er30
Vend Error
Defective main body
of the dispenser
Turn power ON and OFF,
then restart the machine
After reset
releaseReset
Stop
Er33
Piston NO Er.
Piston No. input error
Remove the foreign matter
from the piston travel way
After reset
Stop
Er34
Piston NC Er.
Piston NC. input error
Remove the foreign matter
from the piston travel way
After reset
Stop
Содержание ISI-271THN
Страница 37: ...37 3 Delete hex files in existing hex folder 4 Delete all existing hex files and only leave the copied files ...
Страница 38: ...38 5 Delete date and version from the HEX file name ...
Страница 39: ...39 Wiring diagram ...
Страница 46: ...46 Part List ...
Страница 47: ...47 ...
Страница 48: ...48 ...
Страница 50: ...50 ...
Страница 53: ...53 MEMO ...
Страница 54: ...54 MEMO ...
Страница 55: ...55 MEMO ...
Страница 56: ...3240393 00 온라인 인터넷 서비스 http www icetro com ...