
15
P e r c e n t : 0 % / ---
D r u m : 2 8 . 4 C / ---
S u c . : 2 8 . 5 C / ---
[ A u t o ] L e f t / R i g h t
[ A u t o ]
■■■■■■
75%
■■■■■■
■
BUSY
■
OFF RUN
[ A u t o ]
■■■■■■
100%
■■■■■■
8.0 min
■
■
OFF Break
N o w L o a d : 2 . 4 9 A / ---
S e t L o a d : 2 . 7 7 A / ---
N o L o a d : 2 . 3 7 A / ---
②
The soft ice cream level is set to the default by the manufacturer. Depending on the types
of ingredients and the abrasion of the blade, it should be adjusted properly.
When installing this equipment, the settings for the ingredients should be based on the
suggestion by the installation technician.
When changing the ingredients, consult with a professional to adjust the setting.
For your
information
Making soft ice cream in‘AUTO’mode
To check‘AUTO’mode level set up
To see the raw material information of the
mixing tank in the‘AUTO’mode
After making soft ice cream in the
‘AUTO’mode.
③
Functional description of the buttons
【
Detail description of each mode
】
①
④
⑤
[ A u t o ] L e f t / R i g h t
② Press the‘SELECT’button to display the level setting
(Current, Set-up, No-load) of soft ice cream.
to change soft ice cream level setting, press the‘SET’
button for three seconds.
(For futher details, see‘Adjusting Setting Value’section.)
Pour the raw material in the mixing tank and press the
‘AUTO’button. The following status display will be shown.
① Current level of soft ice cream is indicated.
③ Users can check the hardness of the ice cream and
temperature of the cylinder and part of the suction by
double-pressing the “SELECT” button
④ The time remaining until the restarting of the compressor
will be displayed in Min unit.
(If the ambient temperature is high, the compressor may
start up earlier than the indicated time.)
⑤ Soft ice cream level is indicated.
(After indicating 100%, the value will decrease as time
passes, faster if the ambient temperature is higher).
When soft ice cream has been produced, the compressor
will be shutdown for a while, and the status will be
displayed as shown to the right.
Содержание ISI-271THN
Страница 37: ...37 3 Delete hex files in existing hex folder 4 Delete all existing hex files and only leave the copied files ...
Страница 38: ...38 5 Delete date and version from the HEX file name ...
Страница 39: ...39 Wiring diagram ...
Страница 46: ...46 Part List ...
Страница 47: ...47 ...
Страница 48: ...48 ...
Страница 50: ...50 ...
Страница 53: ...53 MEMO ...
Страница 54: ...54 MEMO ...
Страница 55: ...55 MEMO ...
Страница 56: ...3240393 00 온라인 인터넷 서비스 http www icetro com ...