4-4: Standby off temperature setting
This sets the cylinder’s raw material storage temperature in the
standby mode. When the temperature of this category is too low, the
raw material inside the cylinder freezer and soft freezer can become
like porridge
4-5: Standby management temperature setting
This sets the management temperature to refrigerate the raw
material in the hopper. The temperature set in this category is
managed the value added from the value in Categories 3-4. For
example, if 3-4 is 2
"
and 4-3 is 2
"
, the management temperature
of the hopper is maintained at 6-8
"
.
4-6: Standby reset time setting
This sets the motor’s operation cycle to the standby mode.
When one is satisfied with the temperature value of 4-4 plus 4-5 and
the time of this category, the motor and compressor are operated.
4-7: 1
"
rise level calculation (The left digit)
When the soft freezer is made, 100% is displayed on the green
FND window and the percentage value is deducted from the
compressor rest time.At this time, when 1
"
is added to the
temperature at which the soft freezer is made, the value set for this
category is deduc
t
ed from the percentage and is then displayed.
4-7: 30 seconds pass level calculation (The right number)
When the soft freezer is made, 100% is displayed on the green
FND window and the percentage value is deducted from the
compressor rest time. At this time, the value set for this category is
deduced from the percentage every 30 seconds after the making
of the soft freezer and displayed.
4-8: Upper limit current setting
This category sets the maximum value when adjusting the hardness
of the soft freezer in Category 3-1.
This category
s value needs to be set within the range, in which
excessive current does not flow on the motor.
4-9: Maximum pasteurization time setting
It is set to stop pasteurization when gas leaks or when problems
occur in the pasteurization device. If pasteurization continues until
the time set for this category
4-10: Select between Celsius and Fahrenheit
Select between Celsius (
Ⳅ
) and Fahrenheit (
ⳅ
).
Explanation of the function button (set by an expert)
Содержание ISI-203S
Страница 7: ...7 Part names and controller 4JEF WJFX 4 4 4 1 1BSU 168 1510 SLUG DASER COVER BOLT DRAIN...
Страница 40: ...40 Circuit diagram...
Страница 41: ...41 Circuit diagram...
Страница 42: ...42 Circuit diagram...
Страница 52: ...0OMJOF OUFSOFU 4FSWJDF IUUQ XXX JDFUSP DPN...