Explanation of the function button (set by an expert)
4-0. This is the category that can be selected according to the characteristic and
model of the product and that has a meaning that is different from the
model name of the product. When the model is changed in this category,
the content in Category 4 is reset to the default setting.
4-1: Rest time setting
This is the function to allow the compressor to rest for a certain period
of time by minute after the soft freezer is made. Adjust this category
carefully as it can make the soft freezer melt quickly.
4-2: Set the compressor to restart
This remembers the temperature at the time of making soft freezer.
When the temperature rises above the temperature that was set in
this category, the compressor is restarted. The rest time of the
compressor can be extended when the temperature in this category
is increased.
4-3: Hopper management temperature setting
This sets the management temperature to refrigerate the raw material
in the hopper. The temperature set in this category is managed as the
value added from the value in Categories 3-4. For example, if 3-4 is
2
"
and 4-3 is 2
"
, the management temperature of the hopper
is maintained at 2-4
"
.
Important
matters
The categories that determine the compressor rest time during operation are 4-1 and 4-2. When one
is satisfied with these two categories, the compressor rest time ends.
Model selection: Only experts that have been designated by the main office or by those who received professional
education and received approval from the main office shall adjust this category. A service charge will be applied if
problems occur due to unapproved alterations.
Press
set
+
select
buttons for 3 seconds to enter the stage of
inputting the password.
Password has 4 digits and input begins from the left to the left and the
relevant digit blinks.
Select the number by
-
and
+
buttons and press
set
button to move
to the next digit.
Input the 4 digit password in this way.
Do not let anyone without professional education know the 4 digit
password under any circumstances.