44
We Think of Customer Satisfactio
n
6. Operating Status Display
Item
Display
Front Indicator Lamp
Action
Power Input
Stop (normal status)
Ice Making
Normal operation (run)
Wash
Flickers for 1sec
Normal operation (run)
Full Bin
Stop (normal status)
Water Supply
Trouble
Er 15
Re-operates if the problem
is resolved after checking it
automatically on every hour.
Drainage error
Er 18
Flickers for 0.3sec
Stop
High Pressure
Detection (1time)
Er 13
Flickers for 1sec
High pressure is released
and restarts 1 hour later.
Trouble in Ice
Making
Er 01
Flickers for 0.3sec
Stop
Ice Making Delay
First, Second Times
Er 11
Flickers for 1sec
Restarts after 1 hour
Ice Harvest Delay
First, Second Times
Er 12
Flickers for 1sec
Restarts after 1 hour