Features  

ICELED ZAP+ is a compact handheld controller for use with all ICELED light-sources. 
It is capable of generating a number of automated lighting programs as well as 
providing direct manual control of the colours displayed. The modular nature of 
ICELED products also allows ZAP+ to be connected in-line with any other ICELED 
controller in order to provide instant access to overriding effects. 
 
ZAP+ can also be used to operate the ICELED full-colour scanner, providing access 
to several built-in patterns and sound reactivity (see the Scanner manual for details). 
 

Installation

 

The junction box should be secured to a suitable panel somewhere out of sight. It 
should be located in a position that will make the control box accessible without 
stretching the lead joining the two.  
 
Two out of the three wires from the input cable should be attached to a 12 Volt DC 
supply. Red is for connection to a fused +12 Volt source and Green for connection to 
chassis earth. The Blue wire is an optional data input for connection to another 
ICELED controller. If this is unused it should be left unconnected. ICELED light-
sources connect to the three-way output terminals as shown: 

 

Output 
terminals

 

Input cable

 

Junction box

 

Control box

 

Supply fused 
at no more 
than 5 Amps

 

Any ICELED light source(s) 

with a combined load not 

exceeding 3 Amps

 

+12 VDC

 

Chassis

 

Optional data connection to 

UFO ‘I’ terminal

 

 

If ZAP+ is to be used to override a UFO 
or ZEN output then all three wires in the 
input cable can be connected directly to 
the channel or zone as shown left. 
 

Standby LED

 

Mode 

LEDs

 

Содержание ZAP+

Страница 1: ...public highway ghway ghway ghway to prevent the distraction of other road users Having issued this warning ICELED Will not accept responsibility for any issues arising from failure to comply with thi...

Страница 2: ...d be located in a position that will make the control box accessible without stretching the lead joining the two Two out of the three wires from the input cable should be attached to a 12 Volt DC supp...

Страница 3: ...eat or from an adjustable time base Changing mode Briefly press either of the two buttons to shift to the next mode in turn as indicated by the LEDs The Red button shifts away from Standby through eac...

Страница 4: ...ternal controller The LED serves as a useful indication that the light source is receiving external colour data When in bypass another press of the blue button will inhibit the light source from respo...

Страница 5: ...uttons to change the range of the colour sweep All connected light sources will step through the available ranges indicated by the following four colours Magenta blue to red Yellow red to green Cyan g...

Страница 6: ...ory reset To restore the default values for all settings hold down both buttons when in Standby mode Initially the standby LED will go out then after a pause of several seconds it will light once more...

Страница 7: ...nput Any ICELED controller output 1 Voltage range of between 8 and 18 Volts Reverse polarity and over voltage protection are built in Resources To see the full ICELED product range visit http www icel...

Отзывы: