GEM-MFI SERIES 

 

For the Installer (Location) 

 

Page 6 

 

Location: 

Ice-O-Matic ice machines are designed to be installed indoors in a controlled environment.  Install the ice 
machine in a location where it has enough space around it to be accessible for service.  A minimum of 6 inches 
must be allowed at the back for air circulation on air cooled models.  Try to avoid hot, dirty and crowded 
locations.  Be sure that the location of the machine is within the environmental limitations. 
 

Storage Bin: 

Remove the bin packaging.  Tip the storage bin on its back, using parts of the packaging to protect the exterior 
finish.  Remove the skid and install the legs into the threaded holes in the bottom of the bin.  Turn the leg 
levelers all the way in preparation for leveling later.  Return the bin to the upright position.  
Note:  Do not push the bin into position, but lift it there.  Pushing a bin, especially one with ice in it, can cause 
damage to the bin legs and mounts. 
Install the appropriate bin top according to the instructions provided with the bin top. 
 

Ice machine: 

The ice machine is heavy, so the use of a mechanical lift is recommended for lifting the machine high enough 
to install on top of the bin.  After the unit is placed on the bin, line it up so it is even with the back side.  Secure 
the ice machine to the bin with the hardware provided with the ice machine.  Remove the front panel and 
remove any shipping blocks or packaging material.

  

 

Proper functioning of the bin door requires the bin door, when it is opened, to be in a stable position.  If the ice 
machine is too far forward on the bin, the opened door may not be stable, resulting in an unexpected closing of 
the bin door.  
  
If the ice machine is to be mounted on a bin or dispenser other than an Ice-O-Matic, refer to the manufacturer’s 
instructions for machine mounting.  Ice-O-Matic will not be responsible for damage or injury that results from 
unexpected closing of the bin door as a result of the ice machine being too far forward on the bin. 
 

Water Limitations: 

An ice machine is a food manufacturing plant: it takes a raw material, water and transforms it into a food 
product, ice.  The purity of the water is very important in obtaining pure ice and maximizing product life.  This 
section is not intended as a complete resource for water related questions, but it does offer these general 
recommendations: 
●Check with a water treatment specialist for a water test and recommendations regarding water filters and   

treatment. 

●In most cases, the water used to make ice should be filtered or treated, depending upon the water. 

There is no one type of water filter that is effective in all situations.  That is why a water test in important. 

 

RO Water Limitations: 

Water conductivity must be no less that 35 microSiemens/cm. 
   
 

Notice: 

Ice-O-Matic ice machines are designed and manufactured with the highest regard for safety and performance 
and meet or exceed the standards of UL, NSF and CUL. 
 
Ice-O-Matic assumes no liability or responsibility of any kind for products manufactured by Ice-O-Matic that 
have been altered in any way, including the use of any part and/or other components not specifically approved 
by Ice-O-Matic. 
 
Ice-O-Matic reserves the right to make design changes and/or improvements at anytime.  Specifications and 
design are subject to change without notice.

Содержание GEM Series

Страница 1: ...Installation Start up and Maintenance Manual GEM MFI Series 60 hz Ice O Matic 11100 East 45th Ave Denver Colorado 80239 Part Number 9081403 01 Rev G...

Страница 2: ...Always wear protective eyewear and gloves whenever maintenance or repairs are performed on the ice machine and related equipment Sustainability Program Ice O Matic is devoted to sustainability in ever...

Страница 3: ...taller Guidelines Page 1 For The Installer Applications Page 5 For The Installer Location Page 6 Remote Condenser Page 7 For The Plumber Page 12 For The Electrician Page 14 For The Installer Completed...

Страница 4: ...for carrier s inspection Visible Loss or Damage Any external evidence of loss or damage must be fully described and noted on your freight bill or express receipt and signed by the carrier s agent Clai...

Страница 5: ...not recommended Route bin drain vented float overflow drain and water condenser drain individually to a floor drain The use of condensate pumps for draining water is not recommended by Ice O Matic Ice...

Страница 6: ...GEM MFI SERIES For the Installer Guidelines Page 2 21 Air and Water Cooled...

Страница 7: ...GEM MFI SERIES For The Installer Guidelines Page 3 21 Remote...

Страница 8: ...GEM MFI SERIES For The Installer Guidelines Page 4 30 Remote...

Страница 9: ...T APPROVED All the dispensers have automatic agitation to keep the ice from clumping If agitation is too frequent the Pearl Ice will be damaged and will become difficult to dispense The Ice O Matic an...

Страница 10: ...too far forward on the bin the opened door may not be stable resulting in an unexpected closing of the bin door If the ice machine is to be mounted on a bin or dispenser other than an Ice O Matic refe...

Страница 11: ...on locates the ice machine indoors but in a place where the heat and noise it produces are not objectionable Air cooled machines discharge hot air out the back and must have a minimum of 6 inches of c...

Страница 12: ...hd x 1 hd distance in feet Calculation Drop s Rise s Horizontal Run dd rd hd Calculated Line Length Configurations that do NOT meet these requirements must receive written authorization from Ice O Ma...

Страница 13: ...for connecting information 1 Each set of preharged tubing refrigerant lines consists of a 3 8 diameter liquid line and a 1 2 inch diameter discharge line Both ends of each line have quick connect cou...

Страница 14: ...GEM MFI SERIES Remote Condenser Page 10 Typical Installation REMOTE CONDENSER ICE MACHINE...

Страница 15: ...the swivel nuts by hand until it is certain that the threads are properly engaged 4b Using two wrenches one to rotate the swivel nut and one to hold the tubing tighten each coupling It is CRITICAL th...

Страница 16: ...ent should be followed Drains Air Cooled Models Connect a rigid drain tube to the FPT drain fitting at the back of the cabinet The drain is a gravity type and a inch per foot fall is the minimum accep...

Страница 17: ...s Remote Cooled Models There is one 3 4 inch FPT drain at the back of the cabinet the drain line is of the gravity type and 1 4 inch per foot fall is an acceptable pitch for the drain tubing There sho...

Страница 18: ...is to earth ground Connect the ice machine to its own electrical circuit so it is individually fused Voltage variation must remain within the limitations even under starting conditions Note All extern...

Страница 19: ...imitations even under starting conditions There is a separate junction box for the remote condenser fan motor Install an interconnecting wire between the remote condenser and the junction box at the b...

Страница 20: ...age 16 Completed Installation Remote Condenser Roof Cut A Way Remote Line Set Ice Machine A typical installation should generally appear as illustrated below The best place for the remote condenser is...

Страница 21: ...ments _____4 Have all the plumbing connections been made and checked for leaks _____5 Is the ice machine and storage bin level _____6 Is there a minimum of 6 inches of clearance at the back of the mac...

Страница 22: ..._6 Is the water pressure a minimum of 20 psig ___7 Has the machine been secured to the bin or dispenser ___8 Is there a water shut off valve installed near the machine ___9 Is the remote condenser ins...

Страница 23: ...On air cooled models the condenser will begin to discharge warm air on water cooled models the water regulating valve will open and warm water will be discharged into the drain 5 The unit should soon...

Страница 24: ...the King Valve 4 Switch the master switch ON The electrical start up sequence in automatic a There should be a short 15 second delay before the gear motor starts and the liquid line opens b After the...

Страница 25: ...ice machine and or Bin Dispenser perform the following 1 Remove the ice machine front panel 2 Turn the machine OFF at the ON OFF selector switch 3 Remove all ice in the storage bin Required for cleani...

Страница 26: ...Questions Ice O Matic Ice Machine Bin Cleaning Cleaning or de liming an ice machine refers to the process of removing mineral buildup and scale from the evaporator and other components Ice O Matic rec...

Страница 27: ...b When cleaning the Condenser check the fan blade for cleanliness and for balance Balance is checked by spinning the blade by hand and looking for any wobble Pull on the shaft in several directions to...

Страница 28: ...brush Disconnect electrical power and remove the air filter if applicable The filter may be cleaned or replaced Clean the condenser the condenser may appear to be clean on the surface but it can stil...

Страница 29: ..._________________ ________________________________________________________________________________________ ________________________________________________________________________________________ ____...