Precautions and preparations listed are for general knowledge and to define basic guidelines. Local codes and existing practices should be observed and preformed by a professional. 

Due to Ice Air’s ongoing product development programs, the information in this document is subject to change without notice.

Sequence of Operation for Hybrid Heat Pump

Cooling Cycle

The thermostat calls for Cooling; the cooling motorized valve is 
OPEN, while the heating motorized valve remains closed. 
•  This sends a 24-volt signal through the cool terminal to the 

compressor contactor and the compressor starts.

•  At the same time a 24-volt signal flows through the fan relay 

and the blower starts in HIGH speed if the unit is in Auto Fan 
Mode. If the unit is a manual mode set by the user then the fan 
continuously blows in the user set speed.

•  Once the thermostat is within 2 degrees of set point, the fan 

drops to LOW speed if in Auto Fan Mode

•  The thermostat is satisfied and this sends the 24-volt signal to 

the compressor contactor and compressor turns OFF.

•  This ends the 24-volt signal to the indoor blower relay and the 

blower stops if the unit is in Auto Fan Mode. 

•  This ends the call for cooling.
•  The system is now OFF (except in manual cool set by user, 

where the fan blows continuously)

•  When there is no call for cooling, the motorized valve will remain 

open

Heating Cycle

Setting the thermostat to the HEAT mode automatically de-energizes 
the heating motorized valve OPEN, while the cooling valve closes.
•  A 24-volt signal flows through the fan relay and the blower starts 

in HIGH speed if the unit is in Auto Fan Mode. If the unit is a 
manual mode set by the user then the fan continuously blows in 
the user set speed.

•  The system is now in operation.
•  Once the ambient temperature is within 2 degrees of the set 

point, the fan switches to low speed if the unit is in Auto Fan 
Mode. 

•  As the space warms, the thermostat call is satisfied and ends 

the call for heat.

•  This ends the 24-volt signal to the blower and the unit stops if 

the unit is in auto changeover. If the unit is a manual mode set by 
the user then the fan continuously blows in low speed.

•  The system is now OFF (except in manual heat set by user, then 

the fan blows continuously)

•  The heating motorized valve solenoid stays OPEN (de-energized) 

as long as the thermostat is set for heating.

PLEASE NOTE: 

Other thermostats are available including: 

System compatible with other 3

rd

 party thermostats not shown here. 

For more information go to: 

www.ice-air.com/thermostats

Habitat Wireless 

Thermostat

Digital Touchscreen 

Thermostat

Содержание HHW

Страница 1: ...Parts Exploded View 4 HHW Nomenclature 5 HHW Nomenclature 6 Controls 7 12 LCD Programmable Operation 8 12 Maintenance 11 12 Troubleshooting 13 Warranty Contact Information 14 Table des mati res Bienv...

Страница 2: ...intenance Ice Air HWCACs will provide many years of efficient quiet and trouble free comfort To enhance the use of your Ice Air equipment you will want to read and carefully follow all of the instruct...

Страница 3: ...d electrical circuit with the correct voltage and proper amperage capacity to match the unit nameplate requirements Each unit s electrical circuit must have a proper overcurrent protection device empl...

Страница 4: ...ed by a professional Due to Ice Air s ongoing product development programs the information in this document is subject to change without notice Components and Parts View RIGHT HAND RETURN END DISCHARG...

Страница 5: ...Item 8 S Drain Pan P Galvanized Powder Coated S Stainless Steel Item 9 X Riser Set X Not applicable Item 10 X Casing Stand X Not applicable Item 11 A Flow Control A Autoflow Valve B Manual Balancing V...

Страница 6: ...Stainless Steel Item 9 X Riser Set X Not applicable Item 10 X Casing Stand X Not applicable Item 11 A Flow Control A Autoflow Valve B Manual Balancing Valve C Manual Circuit Setter X None Item 12 A A...

Страница 7: ...y programs for highest efficiency Factory or field set temperature limits Large clear display in any lighting condition Auto changeover mode Easy to program Wireless Thermostat Optional Easy programmi...

Страница 8: ...is on constant display is the ambient room temperature The Cool limit setting is 55 F to 95 F The Heat limit setting is 51 F to 91 F Operation Normal Mode 1 Press ON OFF to turn on thermostat 2 Press...

Страница 9: ...Override icon will turn on 2 In Heat mode Heat set point can be adjusted 3 In Cool mode Cool set point can be adjusted 4 In Auto mode Heat set point will be set first and press UP or DOWN to set the...

Страница 10: ...g The system is now OFF except in manual cool set by user where the fan blows continuously When there is no call for cooling the motorized valve will remain open Heating Cycle Setting the thermostat t...

Страница 11: ...clean the drain pan and drain hoses frequency of cleaning depends on the level of dirt and pollutants that may be present in the indoor environment Evaporator Coil Check and clean if necessary the uni...

Страница 12: ...uld lead to erosion and fouling Evaporator Coil Check the coil for cleanliness and uniformity of fins If the coil is dirty vacuum clean with a soft brush attachment This is the only form of cleaning t...

Страница 13: ...or dirty filters 6 Check indoor fan for proper operation 7 Check that unit did not cycle off due to improper thermostat settings 8 Check for fault codes on the control board consult the Board Troubles...

Страница 14: ...lude 2nd 5th year full unit parts only warranty 2nd 5th year compressor parts and labor warranty so long as such labor is performed in the NY Metropolitan Area 2nd 5th year complete parts and labor wa...

Страница 15: ...iculi re la section des informations sur la s curit et les avertissements au d but du guide ainsi qu aux divers avis de s curit qui apparaissent tout au long du guide Veuillez conserver le pr sent gui...

Страница 16: ...it lectrique distinct dont la tension et l intensit de courant capacit correspondent aux exigences figurant sur la plaque signal tique de l appareil Le circuit lectrique de chaque appareil doit tre do...

Страница 17: ...raison des programmes de d veloppement continu des produits Ice Air le pr sent document contient des informations susceptibles d tre modifi es sans pr avis Vue des composants et des pi ces REPRISE DRO...

Страница 18: ...P Moteurs P condensateur permanent E commutation lectronique B CC sans balai l ment 6 D Source d alimentation D Sectionneur sans fusible X Aucune l ment 7 X Siphon P E Externe exp di s par ment X Aucu...

Страница 19: ...ndensateur permanent E commutation lectronique B CC sans balai l ment 6 D Source d alimentation D Sectionneur sans fusible X Aucune l ment 7 P Siphon P P Interne l ment 8 G Bac condensats P Galvanis e...

Страница 20: ...r une efficacit maximale Limites de temp ratures r gl es en usine ou sur place Grand cran lecture facile dans toutes les conditions d clairage Changement automatique du mode Facile programmer Thermost...

Страница 21: ...permanente BAS Mode de suspension BAS Mode de suspension permanente ON OFF ON OFF marche arr t MODE Choix du mode de fonctionnement R glage interne FAN ventilateur Choix de la vitesse du ventilateur...

Страница 22: ...ilateur quand vous avez termin La limite de temp rature de climatisation doit tre sup rieure d au moins 2 2 C 4 F la limite de temp rature de chauffage 8 Si vous ne pressez aucune touche pendant quinz...

Страница 23: ...e la vanne motoris e du chauffage reste ferm e Un signal de 24 volts est transmis la borne de climatisation pour tre envoy au contacteur du compresseur puis le compresseur d marre En m me temps un sig...

Страница 24: ...uyaux d coulement la fr quence du nettoyage d pend de la quantit de salet s et de polluants pouvant se trouver dans l environnement int rieur Serpentin vaporateur V rifiez chaque ann e le serpentin va...

Страница 25: ...sur le serpentin ce qui permettra d viter l rosion et l encrassement du serpentin Serpentin vaporateur V rifiez le serpentin pour vous assurer qu il est propre et que ses ailettes sont uniformes Si le...

Страница 26: ...e qui pourrait expliquer le non fonctionnement de l appareil 8 V rifiez les codes d erreur apparaissant sur le tableau de commande consultez la grille de d pannage du tableau de commande p CE SYMBOLE...

Страница 27: ...Air n est pas responsable de la maintenance n cessaire pour corriger les probl mes dus un usage impropre une mauvaise installation un c ble inad quat une tension incorrecte ou l ouverture non autoris...

Отзывы: