Model Selection

8

FCHU 08

-

E M X X 6 2 B S X - 22 A G A A 1 P P M F S

Item Number

1

2

3

4 5 6 7 8 9 10 11 12

13 14 15 16 17 18 19 20 21 22 23

Primary Part

Secondary Parts

Valve Package Parts

Valve Package Nomenclature

Item 13

22

Motorized Valve 
Package

22

-  Line Voltage 2 Way Motorized Valve Heat NO, 

Cool NO

23

-  Line Voltage 2 Way Motorized Valve Heat NC, 

Cool NO

24

-  Line Voltage 2 Way Motorized Valve Heat NO, 

Cool NC

25

-  Line Voltage 2 Way Motorized Valve Heat NC, 

Cool NC

26

-  Line Voltage 3 Way Motorized Valve #1 NO 

Diverting, #2 NO Diverting

27

-  Line Voltage 3 Way Motorized Valve #1 NC 

Diverting, #2 NO Diverting

28

-  Line Voltage 3 Way Motorized Valve #1 NC 

Diverting, #2 NC Diverting

29

-  24V 2 Way Motorized Valve Heat NO, Cool 

NO

30

-24V 2 Way Motorized Valve Heat NC, Cool NO

31

-  24V 2 Way Motorized Valve Heat NO, Cool NC

32

-  24V 2 Way Motorized Valve Heat NC, Cool NC

33

-  24V 3 Way Motorized Valve #1 NO Diverting, 

#2 NO Diverting

34

-  24V 3 Way Motorized Valve #1 NC Diverting, 

#2 NO Diverting

35

-  24V 3 Way Motorized Valve #1 NC Diverting, 

#2 NC Diverting

21

-  Wired for 24V Motorized Valve control - MV 

by others

X

-   None

Item 14

A

Electric Heat

A

- 1   

B

- 1.5   

C

- 2   

D

- 3   

E

- 3.5   

F

- 4.3   

G

- 5   

H

- 6   

I

- 7.5   

J

- 10   

X

- No Electric Heat

Item 15

G

Secondary Drain 
Pan

G

- Galvanized Powder Coated (Antique White)   

S

- Stainless Steel   

X

- None

Item 16

A

Flow Regulation 
Cooling Coil

A

- Balancing Valve 

B

- Circuit Setter 

C

- Autoflow Valve 0.5 GPM 

D

- Autoflow Valve 1.0 GPM 

E

- Autoflow Valve 1.3 GPM 

F

- Autoflow Valve 1.5 GPM

G

- Autoflow Valve 2.0 GPM 

H

- Autoflow Valve 2.5 GPM 

I

- Autoflow Valve 2.8 GPM

J

- Autoflow Valve 3.0 GPM 

K

- Autoflow Valve 3.3 GPM 

L

- Autoflow Valve 3.5 GPM

M

- Autoflow Valve 4.0 GPM 

N

- Autoflow Valve 4.5 GPM 

O

- Autoflow Valve 5.0 GPM 

P

- Autoflow Valve 5.5 GPM 

Q

- Autoflow Valve 6.0 GPM 

R

- Autoflow Valve 6.5 GPM

S

- Autoflow Valve 7.0 GPM 

T

- Autoflow Valve 7.5 GPM 

U

- Autoflow Valve 8.0 GPM

V

- Autoflow Valve 8.5 GPM 

W

- Autoflow Valve 9.0 GPM 

X

- None

Item 17

A

Flow Regulation 
Heating Coil

A

- Balancing Valve 

B

- Circuit Setter 

C

- Autoflow Valve 0.5 GPM

D

- Autoflow Valve 1.0 GPM 

E

- Autoflow Valve 1.3 GPM 

F

- Autoflow Valve 1.5 GPM

G

- Autoflow Valve 2.0 GPM 

H

- Autoflow Valve 2.5 GPM 

I

- Autoflow Valve 2.8 GPM

J

- Autoflow Valve 3.0 GPM 

K

- Autoflow Valve 3.3 GPM 

L

- Autoflow Valve 3.5 GPM

M

- Autoflow Valve 4.0 GPM 

N

- Autoflow Valve 4.5 GPM 

O

- Autoflow Valve 5.0 GPM 

P

- Autoflow Valve 5.5 GPM 

Q

- Autoflow Valve 6.0 GPM 

R

- Autoflow Valve 6.5 GPM

S

- Autoflow Valve 7.0 GPM 

T

- Autoflow Valve 7.5 GPM 

U

- Autoflow Valve 8.0 GPM

V

- Autoflow Valve 8.5 GPM 

W

- Autoflow Valve 9.0 GPM 

X

- None

Item 18

1

Y-Strainer

1

- Y-Strainer   

2

- Y-Strainer Blow Down   

X

- None

Item 19

P

Purge Valve

P

- Yes   

X

-No

Item 20

P

PT Ports

P

- Yes   

X

-No

Item 21

M

Air Vents

M

- Manual   

A

- Automatic   

X

- None

Item 22

F

Condensate 
Overflow Switch

F

- Float   

E

- Electronic   

X

- None

Item 23

S

Pipe Connections

S

- Sweat   

M

- Male NPT   

F

- Female NPT   

U

- Unions

MV = Motorized Valve

Содержание FCHC

Страница 1: ...and existing practices should be observed and preformed by a professional Due to ICE AIRs ongoing product development programs the information in this document is subject to change without notice FCHC...

Страница 2: ...nce Manual We recommend that you pay special attention to the Safety and Warning Information section at the beginning of this Manual and to the various safety advisories throughout this Manual Please...

Страница 3: ...Our ICE AIR units must each be wired on an individual dedicated electrical circuit with the correct voltage and proper amperage capacity to match the unit nameplate requirements Each unit s electrical...

Страница 4: ...mation in this document is subject to change without notice Components and Parts View Horizontal Concealed Ultra Thin TOP VIEW FRONT VIEW RIGHT VIEW JUNCTION BOX AIR SUPPLY CONDENSATE DRAIN DRAIN PAN...

Страница 5: ...l Elec Heat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Ite...

Страница 6: ...ay MV Normally Open Diverting 17 24V 3 Way MV Normally Closed Routing w Bypass Pipe 18 24V 3 Way MV Normally Closed Diverting w Bypass Pipe 19 24V 3 Way MV Normally Open Routing w Bypass Pipe 20 24V 3...

Страница 7: ...eat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Item 6 X En...

Страница 8: ...J 10 X No Electric Heat Item 15 G Secondary Drain Pan G Galvanized Powder Coated Antique White S Stainless Steel X None Item 16 A Flow Regulation Cooling Coil A Balancing Valve B Circuit Setter C Auto...

Страница 9: ...Thermostat should be no more than 5 10 feet from the unit for optimal connection The ICE AIR unit is compatible with certain third party thermostats For ideal location information please contact your...

Страница 10: ...Press Hold s UP Override mode UP Permanent Override mode t DOWN Override mode DOWN Permanent Override mode ON OFF ON OFF MODE Set operation mode Internal Setting FAN Set fan speed Confirm The tempera...

Страница 11: ...set point can be adjusted 4 In Auto mode Heat set point will be set first and press UP or DOWN to set the Heat set point Press FAN to confirm the Heat set point Cool set point will be set second and...

Страница 12: ...mode and inlet water temperature is below 85 F the Auto Seasonal Changeover switch shall open the valve and allow cool water to circulate through the system else the valve remains shut to prevent hot...

Страница 13: ...ternal components may vary based on installed conditions NOTE Pictures of components and parts may vary depending on your model Indoor Air Filter if applicable Only configurations with a plenum on the...

Страница 14: ...ree service The procedures should be implemented by trained personnel But there are certain items that you the apartment owner or tenant can do to ensure proper unit function Keep the area around your...

Страница 15: ...and current against the electrical specifications on the unit nameplate 3 Look for wiring errors Check for loose screw connections in both line and low voltage terminals 4 Check the water supply pipi...

Страница 16: ...person including any agent salesman dealer or distributor has authority to expand ICE AIRs obligation beyond the terms of these express warranties or to state that the performance of the product is ot...

Отзывы: