background image

16

Precautions and preparations listed are for general knowledge and to define basic guidelines. Local codes and existing practices should be observed and preformed by a professional. 

Due to ICE AIRs ongoing product development programs, the information in this document is subject to change without notice.

Twelve (12) Month Warranty of ICE AIR units – ICE AIR, 
LLC, herein referred to as “ICE AIR,” warrants to the 
original owner that the entire unit is free from defects 
in material and workmanship for a period of twelve (12) 
months from the date of delivery. Any part of portion 
thereof which becomes defective under normal use 
during the period of this warranty will be repaired or 
replaced provided ICE AIRs examination shall prove to its 
satisfaction that the part was or became defective under 
normal use. ICE AIRs obligations under this warranty 
are limited to: (a) Repairing the defective part or (b) 
furnishing a replacement part provided the defective 
part is returned to the factory, without shipping damage, 
transporting charges prepaid. No reimbursement will be 
made for expenses incurred in making fi eld adjustments 
or replacements unless specifi cally authorized in writing 
by the Company.

The Company is not obligated under this warranty for 
fi eld labor such as service for inspection, removing, 
packing and/or reinstalling water source unit, nor for the 
return transportation charges.

OPTIONAL Extended Refrigeration 
Circuit Warranty

The Optional Extended Refrigeration Circuit Warranty 
MUST be purchased from ICE AIR within thirty (30) days 
from date of delivery to be valid. The hermetically sealed 
refrigeration circuit (consisting of the motor, compressor 
assembly, evaporator coil, coaxial/condenser coil and 
interconnecting tubing) is warranted to the original 
owner for four additional years from date of the 
expiration of the Twelve Month Warranty. Components 
under this warranty will be supplied at ICE AIRs expense 
provided the failed component is returned to the factory. 
This optional warranty does not include any other parts 
of the equipment such as fans, fan motors, controls, 
cabinet parts, electrical relays, capacitors, protective 
devices, or wiring. ICE AIR is not obligated under this 
warranty for fi eld labor such as service for inspection, 
removing, packing, and/or reinstalling the refrigeration  
circuit, nor for return transportation charges. ICE AIR 
reserves the right to make a handling and inspection 
charge in the case of parts or equipment improperly 
returned as defective and/or as being in warranty.

To obtain assistance under the parts warranty or to 
purchase the optional extended warranty, simply contact 
ICE AIR Customer Service at 80 Hartford Avenue, Mount 
Vernon, New York 10553. Telephone 

914-668-4700

.

The Twelve Month and the OPTIONAL Extended 
Refrigeration Circuit Warranty (which must be purchased 
separately) constitute the buyer’s sole remedy. They are 
given in lieu of all other warranties. There is no implied 
warranty of merchant-ability or fi tness for a particular 
purpose. In no event and under no circumstance 
shall ICE AIR be liable for incidental or consequential 
damages, whether the theory is breach of this or any 
warranty, negligence, or strict tort.

No person (including any agent, salesman, dealer or 
distributor) has authority to expand ICE AIRs obligation 
beyond the terms of these express warranties, or to 
state that the performance of the product is other than 
that published by ICE AIR.

General Conditions

The above warranties are void if ICE AIRs equipment 
has been damaged, misused, subjected to abnormal 
use or service or its serial number has been altered, 
defaced, or removed, or payment for the equipment is in 
default. ICE AIR is not responsible for service to correct 
conditions due to misapplication, improper installation, 
inadequate wiring, incorrect voltage conditions or 
unauthorized opening of the refrigeration circuit, nor for 
consequential damages. In case ICE AIRs equipment 
is installed in conjunction with cabinets, grills, louvers, 
controls or other parts manufactured by others, these 
warranties shall apply only to ICE AIRs manufactured 
portion of the equipment. The conditions of the standard 
warranty plan are effective for 18 months from TCO. ICE 
AIR reserves the right to make a handling and inspection 
charge in the case of parts or equipment improperly 
returned as defective and/or as being warranty.

Important

The following are the responsibility of the user. They 
are not manufacturing defects, and are therefore not 
included in the warranty plan.

1)  Failure of unit to operate satisfactorily due to 

improper amount of air on evaporator coil or air 
supply to air cooled condensers.

2)  Damage to unit or unsatisfactorily operation due to 

improper cleaning of evaporator coil or use of unit 
in corrosive atmosphere locations such as chemical 
plants, refi neries, or salt spray areas.

3)  Damage to unit from unsatisfactory operation due 

to blown fuses, inadequate or interrupted electrical 
service, use of improper electrical protective devices 
or operation of unit on power supply other than 
covered by nameplate rating of unit.

4)  Damage due to failure to properly maintain unit.

5)  Damage due to transportation or handling prior to and 

during installation.

6)  Damage due to accident or from alteration, improper 

installation, tampering.

7) Filter cleaning or replacement.
8) Misapplication.

Check, Test and Start

Check, Test and Start of the air conditioners by an 
experienced person is the responsibility of the installing 
contractor. This consists of physically confronting each 
unit operating in both heating and cooling modes and 
correcting any minor defi ciencies noted. After the 
equipment leaves the factory, it may become damaged 
or maladjusted during transportation or on the job. 
Sometimes wires are disconnected accidentally, or fan 
motors move on their bases due to rough handling, 
causing fans to strike; a component(s) may be 
inoperable. The correction of such conditions is part of 
the Check, Test and Start. Note that unless otherwise 
specifi cally agreed to in writing, ICE AIR includes no fi eld 
labor, Check, Test, and Start (or the like) in the price of 
its equipment.

Installation

ICE AIR is not responsible for the design, execution 
and performance of the installation method or any of 
the accessory items used during installation such as 
seals, caulking, weatherproofi ng, supporting structures, 
attachment means, louvers and frames supplied by 
others.

80 Hartford Avenue, Mount Vernon, NY 10553
Tel: 877-ICE-AIR-1 (877-423-2471)
Fax: 914-668-5643
email: [email protected]

www.ice-air.com

© 2017 by ICE AIR, LLC 

ICE6088  07/16

Limited Warranty

Содержание FCHC

Страница 1: ...and existing practices should be observed and preformed by a professional Due to ICE AIRs ongoing product development programs the information in this document is subject to change without notice FCHC...

Страница 2: ...nce Manual We recommend that you pay special attention to the Safety and Warning Information section at the beginning of this Manual and to the various safety advisories throughout this Manual Please...

Страница 3: ...Our ICE AIR units must each be wired on an individual dedicated electrical circuit with the correct voltage and proper amperage capacity to match the unit nameplate requirements Each unit s electrical...

Страница 4: ...mation in this document is subject to change without notice Components and Parts View Horizontal Concealed Ultra Thin TOP VIEW FRONT VIEW RIGHT VIEW JUNCTION BOX AIR SUPPLY CONDENSATE DRAIN DRAIN PAN...

Страница 5: ...l Elec Heat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Ite...

Страница 6: ...ay MV Normally Open Diverting 17 24V 3 Way MV Normally Closed Routing w Bypass Pipe 18 24V 3 Way MV Normally Closed Diverting w Bypass Pipe 19 24V 3 Way MV Normally Open Routing w Bypass Pipe 20 24V 3...

Страница 7: ...eat MCO K LH 2 Pipe Cool w Total Elec Heat ACO L LH 2 Pipe Heat Only M RH 4 Pipe Heat and Cool MCO N RH 4 Pipe Heat and Cool ACO O LH 4 Pipe Heat and Cool MCO P LH 4 Pipe Heat and Cool ACO Item 6 X En...

Страница 8: ...J 10 X No Electric Heat Item 15 G Secondary Drain Pan G Galvanized Powder Coated Antique White S Stainless Steel X None Item 16 A Flow Regulation Cooling Coil A Balancing Valve B Circuit Setter C Auto...

Страница 9: ...Thermostat should be no more than 5 10 feet from the unit for optimal connection The ICE AIR unit is compatible with certain third party thermostats For ideal location information please contact your...

Страница 10: ...Press Hold s UP Override mode UP Permanent Override mode t DOWN Override mode DOWN Permanent Override mode ON OFF ON OFF MODE Set operation mode Internal Setting FAN Set fan speed Confirm The tempera...

Страница 11: ...set point can be adjusted 4 In Auto mode Heat set point will be set first and press UP or DOWN to set the Heat set point Press FAN to confirm the Heat set point Cool set point will be set second and...

Страница 12: ...mode and inlet water temperature is below 85 F the Auto Seasonal Changeover switch shall open the valve and allow cool water to circulate through the system else the valve remains shut to prevent hot...

Страница 13: ...ternal components may vary based on installed conditions NOTE Pictures of components and parts may vary depending on your model Indoor Air Filter if applicable Only configurations with a plenum on the...

Страница 14: ...ree service The procedures should be implemented by trained personnel But there are certain items that you the apartment owner or tenant can do to ensure proper unit function Keep the area around your...

Страница 15: ...and current against the electrical specifications on the unit nameplate 3 Look for wiring errors Check for loose screw connections in both line and low voltage terminals 4 Check the water supply pipi...

Страница 16: ...person including any agent salesman dealer or distributor has authority to expand ICE AIRs obligation beyond the terms of these express warranties or to state that the performance of the product is ot...

Отзывы: