6) MANTENIMIENTO Y LIMPIEZA
When you finish working, always remove the Roner20 from its
container to prevent moisture from entering it.
Before cleaning, turn off and unplug the Roner20.
Make sure the Roner20 is stored at room temperature.
If you remove the water pump cover, remember to put it back
to function normally. Check for any signs of damage, including
pulled cord or physical damage to the system or heaters.
After prolonged use and depending on the hardness and quality
of the water, it may acquire limescale deposits on the heater
and the casing. To remove this lime, it is suggested to leave it in
operation at 70°C with a mixture of water and white vinegar,
from 2% to 5% depending on the state of incrustation for 30
minutes.
(* Caution: in case of splashing vinegar in the eyes, rinse quickly
and thoroughly with water. If the eye is still red, painful, has
tears and is sensitive to light, medical advice is required).
Let cool slightly, remove the bottom cover and clean with a
brush.
When it comes to internal machinery problems, the technical
service work should only be performed by certified personnel.
Technical service: contact ICC.
13