Enter a “Name” which will allow easy identification of the inverter on the network (the tags created
in RSLogix 5000 will
be derived from this “Name”). Enter the “IP address” of the targeted interface
card.
13)
Click on the “Connection” tab. Refer to Figure 33.
Figure 33: AOP New Module Properties Connection Tab
Confirm the setting of the “Requested Packet Interval (RPI)”. The RPI defines the amount of time
(in milliseconds) between data exchanges across an I/O connection. The smallest RPI supported
by the interface card is 1ms. Click “OK” when done.
14) You should now see the interface card in the 1756-ENBT/A branch under the I/O Configuration in
the controller organizer view. The full I/O Configuration tree should appear similar to Figure 34.
Figure 34: AOP Interface Card I/O Configuration
15) Continue with the AOP Generic I/O Messaging example in section 10.2.11.1 or AOP AC/DC Drive
Profile example in section 10.2.11.2.
10.2.11.1
ControlLogix Example: EDS Add-On Profile (AOP) Generic I/O Messaging
This section will demonstrate how to configure the EtherNet/IP Generic I/O connection.
1)
Complete all steps in section 10.2.11.
2)
Locate the interface card in the 1756-
ENBT/A branch under the “I/O Configuration” in the controller
organizer view. Right cl
ick on the interface card, choose “Properties”, and select the “General” tab.