LINK5000 series Installation Guide

2-1

Chapter 2 Hardware Installation

2.1 Installation Notice

Please  follow  all  safety  instructions  to  ensure

proper  operation  of

the

Link5010AS-POE, your physical security as well as the on-going warranty of the unit.

2.1.1 Environmental Requirements

The switch must be installed in a clean area with ample ventilation and free of dust,

otherwise, the switch may be damaged by electrostatic adherence.

Maintain the temperature and the humidity within the set environment.

The  switch  must  be  put  in  a  dry  and  cool  place. Please  ensure sufficient  spacing

around the switch for good air circulation.

The switch must work in the right range of power input.

The  switch  must  be  well  grounded  in  order  to  avoid  ESD  damage  and personal

physical injury.

Avoid  direct  sunlight  on  the  switch.  Keep  the  switch  away  from  heat  sources  and

strong electromagnetic interference sources.

The  switch  must  be  mounted  to  a  standard  19’’  rack  or  placed  on  a  clean  level

desktop.

2.1.1.1 Dust and Particles

Dust  is  harmful  to  the  safe  operation  of the switch. Dust  can  lead  to  electrostatic

adherence,  especially  under  low  relative  humidity,  causing  poor  contact  of  metal

connectors  or  contacts.  Electrostatic  adherence  will  result  not  only in reduced  product

lifespan, but also increased chance of communication failures. The recommended value

for dust content and particle diameter in the site is shown below:

Max Diameter (µm)

0.5

1

3

5

Max Density (particles/m³)

1.4×10

5

7×10

5

2.4×10

5

1.3×10

5

Table 2-1 Environmental Requirements: Dust content

In  addition,  salt,  acid  and  sulfide  in  the  air  are  also  harmful  to  the  switch.  Such

harmful gases will aggravate metal corrosion and the aging of some parts. The site should

Содержание icXchange Link5000 Series

Страница 1: ...Xchange Advanced Ethernet Switch Link5000 Series ICC Networking Advanced Gigabit Switch Product Model Link5010AS POE Description 10 Port Gigabit Advanced Layer 2 Managed Switch with Power over Etherne...

Страница 2: ...al Requirements 2 1 2 1 2 Installation Notice 2 4 2 1 3 Security Warnings 2 4 2 2 Installation Preparation 2 5 2 2 1 Verify the Package Contents 2 5 2 2 2 Required Tools and Materials 2 5 2 3 Installa...

Страница 3: ...a variety of manuals installation guides videos knowledge articles sample designs troubleshooting and FAQ guides to assist you with the deployment of your new and innovative solution These and other d...

Страница 4: ...n the front of the unit The Link5010AS POE switch comes loaded with advanced intelligent software content control capabilities and security features that fit into any access or distribution layer for...

Страница 5: ...LEDs 110 220V AC power socket and 1 grounding screw The front panel of Link5010AS POE is shown as follow Fig1 2 Front Panel of Link5010AS POE 1 2 2 Back Panel The back panel of Link5010AS POE is show...

Страница 6: ...Panel Symbol Status Description Port1 8 Link Act On Green The port is successfully connected Flash Green The port is successfully connected and receive send data Off The port is not connected Port9 1...

Страница 7: ...I MDI X cable mode auto negotiation 5 types of UTP 100 meters SFP SFP SX L transceiver 1000Base SX SFP 850nm MMF 550m SFP LX L transceiver 1000Base LX SFP 1310nm SMF 10km or MMF 550m SFP LX 20 L trans...

Страница 8: ...al physical injury Avoid direct sunlight on the switch Keep the switch away from heat sources and strong electromagnetic interference sources The switch must be mounted to a standard 19 rack or placed...

Страница 9: ...l circuits Temperature extremes can cause reduced reliability and premature aging of insulation materials thus reducing the switch s working lifespan The recommended temperature and humidity are shown...

Страница 10: ...ectric can cause damage to internal circuits and the entire switch Follow these guidelines for avoiding ESD damage Ensure proper grounding of the device Perform regular cleaning to reduce dust Maintai...

Страница 11: ...instruction carefully before using the system During the installation users must use the brackets and screws provided in the accessory kit Users should use the proper tools to perform the installation...

Страница 12: ...which case the user may be required to take adequate measures Caution Potential risks include Electric leakage Power supply arcing Power line breakage Overload circuit and Electrical short circuit If...

Страница 13: ...the switch to ensure the proper operation of the switch 2 3 2 Connecting Console Link5010AS POE includes an RJ45 serial console port The connection procedure is listed below 1 Find the console cable...

Страница 14: ...above the port to ensure that the right port is being used Connecting to wrong ports might damage the switch Fiber cables should be connected as below Step 1 Remove the protective plug from the SFP XF...

Страница 15: ...wer source socket with overload and leakage protection and the other end to the power socket in the back panel of the switch 2 Check the power status indicator in the front panel of the switch The cor...

Страница 16: ...nect the switch to the PC by using an Ethernet cable not included to connect the PC to one of the switch s Ethernet ports 2 Configure the IP address for the PC and ensure that it can communicate with...

Страница 17: ...the web network management page to quit without committing any changes made to the configuration or click on Save Exit to exit with committing the configuration changes to the memory icXchange web ma...

Страница 18: ...tibility Directive EMC 1999 5 EEC Radio Equipment and Telecommunications Terminal Equipment Directive R TTE Specifications International Communications Corporation Inc hereby declares that the product...

Страница 19: ...rbished or contain refurbished materials Any replaced or repaired product carries the remainder of the initial warranty ICC is not responsible for any Customer or custom software or rmware con guratio...

Страница 20: ...EPAIR OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY TO THE FULLEST EXTENT ALLOWED BY LAW WHETHER BASED IN CONTRACT OR TO...

Страница 21: ...Adobe Systems Inc Mac OS is a registered trademark of Apple Inc Windows Windows Server 2003 Windows Vista and Microsoft Internet Explorer are registered trademarks of Microsoft Cisco is a registered t...

Отзывы: