Brushless Motor Driver SEH400RB

4.2 Terminal Description

4.3 Description of external control signal circuit

The F/R and EN terminals are as below

amplitude ranges less than 0.5V, or higher than 2.5VDC

Signal

Terminals

Description

Power input

L

Power+

N

Power-

E

Ground

Motor lines

U

Motor U

V

Motor V

W

Motor W

E

Ground

Motor hall lines

+5VE

Hall 

HA

Motor hall sensor Hu

HB

Motor hall sensor Hv

HC

Motor hall sensor Hw

GNDE

Hall sensor -

Control signals

SV

External potentiometer speed regulation

EN

If EN and GNDE connect, the motor runs;

If EN and GNDE disconnect, the motor stops. (They disconnect

by default.)

F/R

If F/ and GNDE connect, the motor runs anti-clockwise

If F/ and GNDE disconnect, the motor runs clockwise

GNDE

Control signal common ground port

BRK

Under port control mode P-03-4, BRK connects with GNDE, the

motor brake stops

Output signals

SPD

Frequency output.

The relationship between the frequency detected and the speed is:

N(rpm)= F

F: Output pulse frequency(Hz

N: Motor speed

For example

F=500Hz, then N(rpm)=500

(Note: Motor poles should be set right)

ALM

It is a high resistance output, and when a fault occurs, it outputs a

low level

Содержание SEH400RB

Страница 1: ...Brushless Motor Driver SEH400RB _________________________________________________________________...

Страница 2: ...iver port 3 4 2 Terminal Description 4 4 3 Description of external control signal circuit 4 4 4 Output circuit description 5 5 Introduction to panel functions 6 5 1Panel functions 6 5 2 Panel introduc...

Страница 3: ...ameters Adjustable speed with knob External potentiometer speed regulation Acceleration and deceleration time setting Pole pair setting Alarm display RS485 Rated speed accuracy as low as 0 5 2 Electri...

Страница 4: ...Brushless Motor Driver SEH400RB 3 Mechanical Dimensions Unit mm 4 Driver port and function description 4 1 Driver port...

Страница 5: ...tentiometer speed regulation EN If EN and GNDE connect the motor runs If EN and GNDE disconnect the motor stops They disconnect by default F R If F and GNDE connect the motor runs anti clockwise If F...

Страница 6: ...ternal potentiometer SV input wiring is shown below The external analog SV input wiring is shown below 4 4 Output circuit description ALM and SPD terminals as below its connection mode with PLC is rel...

Страница 7: ...tio setting Set the speed ratio of the reducer Alarm reset Display the alarm code and press SET to reset the alarm Polar number setting Set the pole pairs of the adaptive motor It is not recommended t...

Страница 8: ...Brushless Motor Driver SEH400RB 5 2 Panel introduction 5 3 Drive panel control settings...

Страница 9: ...Brushless Motor Driver SEH400RB Note All settings will be saved automatically immediately even power off without loss...

Страница 10: ...ee right 6 2 Direction control Here are two methods to control the direction 1 Through the panel MODE P 03 2 Disconnect F R and GNDE motor runs clockwise Connect F R and GNDE motor runs anti clockwise...

Страница 11: ...s to the GNDE port and the 5VE port respectively Refer to the picture below for details 2 External analog signal role DC 0 5V Note Be sure to set the correct number of motor pole pairs Relationship be...

Страница 12: ...shown in the figure below and three wires need to be connected B A GNDE The communication address can be set through the panel operation The 120 terminal matching resistance needs to be externally co...

Страница 13: ...0002 0X005F Speed Value 0 65535 0 RPM 0X0003 0X0066 Motor direction 0 4 1 0X0004 0X0068 Gear ratio 1 100 1 0X0005 0X0076 Alarm code 0 0X0006 0X0086 Pole pairs number 1 100 4 0X0007 0X0090 Under speed...

Страница 14: ...scription or note Speed adjusting modes selection 0 Knob speed regulation 1 External analog quantity 2 key or communication Speed setting The motor does not rotate when the set speed is lower than 400...

Страница 15: ...n the driver 2 Re match the motor and driver selection 3 Replace the driver AL05 Hall error 1 Check whether the motor sensor cable is firmly connected 2 Check whether the Hall element in the motor is...

Страница 16: ...on Damage Replace new motor and driver Abnormal motor speed Overload Make the load smaller Signal input wrongly Signal input checking Wrong poles pairs numbers setting Set the right poles numbers Wron...

Страница 17: ...t or electric parameters that does not meet the use parameters is not covered by the warranty Product damage caused by improper selection is not covered by the warranty Product damage caused by unauth...

Отзывы: