Installation instruction:
Installation instruction of the lamp UV
UV lamp cleaning:
16. Connect to power supply
Plug on and start the filter.
17. Adjust water output
Adjust the flow control handle to
adjust the water output.
18. Leakage confirmation
Confirm there is no leakage around
the bucket after power on. Confirm
again 30-60 minutes later.
19. Assemble the power head
20. Turn on the uv lamp, adjust the water flow
21. Disassemble the valve base
Open the pump head and clean the
filtering material as indicated in
steps 1-4. Put the uv lamp sleeve
on the hole on the media basket
and assemble the power head as
indicated in steps 5-8.
Turn on the uv light to kill the bacteria in the water. When the light
indicator is on, you know it is working.
Put the valve base handle in the
“unlock” position and take out the
valve base.
pumping
handle
UV lamp
indicater light
UV lamp
switch
22. Take out uv lamp cover
Separate the pump head as
indicated in steps 1-3, use a “+”
shape screwdriver to unscrew the
screw and take out the uv lamp
sleeve to clean.
23. Clean quartz glass tube
Take out the uv lamp cover, use a
wet towel or water to clean out
the dirt on the quartz glass tube.
Do not take off the quartz tube to
avoid that the water enters into
the circuit board and causes short
circuit.