1. The battery of LS810-B is a built-in rechargeable

     lithium-ion battery, the battery current is 420 mAh.

2. Please use the USB cable to charge

    the battery, just like the following picture:

 Power Supply and Charge Power

Charging the power under following circumstances:

displays on the LCD

The LCD display dims
When powering on the monitor, the LCD doesn’t light up.

 

 

CAUTION

   

   

 

 

1. The battery of the LS810-B is a built-in rechargeable lithium-ion battery; 

please do not disassemble by unauthorized maintenance personel.
2. Under normal use, it can be charged about 300 times. 

If the battery cannot charge the power normally or the blood pressure

monitor cannot be used normally, please connect with the authorized

maintenance personel. If measured three times per day, and the battery 

is fully charged, it can be used for about 20 days.
3. Store and use the blood pressure monitor in a cool, dry, and

ventilated environment. Avoid close proximity to fire and extreme heat

or it can cause the battery to explode.

4. You can only use the IC Science’s authorized USB cable to  

charge the power. You cannot use the blood pressure monitor during 

charging.

5. During charging, the blood pressure monitor displays the symbol:

When the charging is finished, please unplug the device.

6. When charging, do not touch the charging connector and the patient 

simultaneously.

7

Setting Date and Time

2

.As pictured in the right, the 

blinking numeral representing 

[HOUR]. Press “MEM” button to 

change the numeral. Each press 

will increase the numeral by one 

in a cycling manner. 

1.When the monitor is OFF, press 

and hold “SET” button for 3 

seconds to enter Time Setting 

Mode.

3

.Press “SET” button again to 

confirm [HOUR]. Then the 

numeral representing [MINUTE] 

blinks. 

Please proceed to time setting before your initial use to 

ensure each piece of recorded information is labled with a

time stamp. (Year Range: 2012-2052; Time Format: 12 Hours)

When you get the Blood Pressure Monitor, the first thing

you must do is to activate it. Please press and hold the SET

button to activate it, then it will enter the setting mode.

Activate Your Blood Pressure Monitor

Download and install My BP Coach from 

iTunes Store or Google play

Содержание LS-810-B

Страница 1: ...al for further reference in case you have problems Thank you for selecting the IC Sciences Corporation Blood Pressure Monitor LS810 B Wrist Type Version 1 0 MEM SET FCC ID OU9LS810 B01 Distributed by Informed Clinical Sciences Corporation 1 Joy Street Boston USA MA 02108 Download and install My BP Coach from iTunes Store or Google play My BP Coach ...

Страница 2: ...get from the hospital different from home Is the result the same if measuring on the right wrist TROUBLESHOOTING 20 SPECIFICATIONS 21 THE MATCHED COMPONENTS 22 CONTACT INFORMATION 22 Safety Information Power Supply and Charge Power Activate Your Blood Pressure Monitor Setting Date and Time Positioning the Cuff Start Measurement Data Management 14 Recall the Records Delete the Records COMPLIED STAN...

Страница 3: ... pressure measurement Do not confuse self monitoring with self diagnosis This unit allows you to monitor your blood pressure Please start or end medical treatment basing solely on physician s treatment advice If you are taking medication consult your physician to determine the most appropriate time for your measurement Never change a prescribed medication without your physician s consent This unit...

Страница 4: ... the power Error Memory Recalling the history records Bluetooth Successful Bluetooth Connection IHB Detector Irregular Heartbeat Detector Error 5 SYSTOLIC DIASTOLIC MEM UP BUTTON SET DOWN BUTTON START STOP BUTTON CUFF Type BF applied part PULSE RATE TIME USB Interface Monitor Components List 1 Blood Pressure Monitor LS810 B 2 USB Cable 3 User Manual MEM SET Component list of pressure measuring sys...

Страница 5: ...can cause the battery to explode 4 You can only use the IC Science s authorized USB cable to charge the power You cannot use the blood pressure monitor during charging 5 During charging the blood pressure monitor displays the symbol When the charging is finished please unplug the device 6 When charging do not touch the charging connector and the patient simultaneously 7 Setting Date and Time 2 As ...

Страница 6: ...ch from the bottom of the wrist 5 Fasten the wrist cuff around your wrist leaving no extra room betweenthe cuff and your skin If the cuff is too loose the measurement will not be accurate Rest for 5 minutes before measuring your blood pressure Wait at least 3 minutes between measurements This allows your blood circulation to recover For a meaningful comparison try to measure under similar conditio...

Страница 7: ...itor and it will complete the measurement process Start Measurement CAUTION Interference may occur in the vicinity of equipment marked with the following symbol And LS810 B may interfere in the vicinity of electrical equipment Keep the monitor at least 20 centimeters 8 inches away from the human body especially the head when the data transmission is proceeding after measurement To enable the data ...

Страница 8: ...AF premature ventricular beats and peripheralarterial disease PAD should avoid using the unit whenever possible 1 When using this device please pay attention to the following situations which may interrupt blood flow and influence blood circulation of the patient thus cause harmful injury to the patient too frequent and consecutive multiple measurements the application of the CUFF and its pressuri...

Страница 9: ...ord 60 is dropped from the list CAUTION DATA MANAGEMENT 14 When you did not obtain an accurate measurement you can clear all the results by following the steps below Delete the Records 1 Under Memory Recalling Mode press and hold both the MEM button and the SET button for 3 seconds 2 The LCD will display dEL dONE indicating that memory clearing is complete Then it will shutdown To cancel the clear...

Страница 10: ...it is in proper working conditions before use Don t service or maintain while the device is in use 2 If you have any problems with this device such as setting up maintaining or using please contact Informed Clinical Sciences Do not open or repair the device yourself 3 Please report to Informed Clinical Sciences if any unexpected operation or events occur 4 Cleaning A dusty environment may affect t...

Страница 11: ...as reached a dangerous point CAUTION SYS 135 mm Hg DIA 85 mm Hg Blood Pressure Category Normal Prehypertension High Blood Pressure Hypertension Stage 1 High Blood Pressure Hypertension Stage 2 Hypertensive Crisis Emergency care needed Systolic mmHg upper Diastolic mmHg lower less than 120 120 139 140 159 160 or higher Higher than 180 and or or or or less than 80 80 89 90 99 100 or higher Higher th...

Страница 12: ...splay moder Digital LCD V A 46 5x36 5mm Measurement mode Oscillographic testing mode Measurement range Accuracy Normal working condition Storage transportation condition Measurement perimeter of the wrist About 13 5cm 21 5cm Net Weight Approx 110g External dimensions Attachment Approx 79 8 72 5 13 2mm USB cable user manual Mode of operation Continuous operation Degree of protection Type BF applied...

Страница 13: ... Symbols to be used with medical device labels labelling and information to be supplied General requirements EN 1041 2008 Medical equipment manufacturers to provide information IEC 60601 1 2005 A1 2012 Medical electrical equipment Part 1 General requirements for basic safety and essential performance IEC EN 60601 1 2 2007 Medical electrical equipment Part 1 2 General requirements for basic safety ...

Страница 14: ... This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter EMC Guidance 24 25 1 The Blood Pressure Monitor needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided in the ACCOMPAN...