5. Touch Panel Calibration
5.1 Android RTP re-calibrate procedure
If you want or need to calibrate the touch for any reason such as:
Touch is not accurate
You have changed output
It is your first boot after you updated firmware and set output.
Use the commands to calibrate after devices boot.
When device power on, please notice the messages from console show
‘adb_open’
,
while the message occurred, quick input or paste character
“stop”
and press
“Enter”
key to stop the system booting process. Further then input below commands:
adb_bind_config
adb_open
#
stop
//now the system would stop and display stays at penguin icon
#
ts_calibrator
//now the
re would be a white ‘┼’ at left, it is calibration point
Here is an example of the console message.
When the calibration point
‘
┼
’
shows, please quickly and accurately touch the cross
on panel. Be careful that this calibrator is with timeout function. If it is timeout, just
input
ts_calibrator
again.