Chapter 3 BIOS Configuration
CI7BM User’s Manual
53
Power Management Setup
The Power Management Setup allows you to save energy of your system
effectively. It will shut down the hard disk and turn off video display after
a period of inactivity.
ROM PCI/ISA BIOS
POWER MANAGEMENT SETUP
AWARD SOFTWARE, INC.
ACPI Function
: Enabled
** Reload Global Timer Events **
Power Management
: User Define
IRQ3 (3-7, 9-15), NMI
: Disabled
PM Control by APM
: Yes
Primary IDE 0
: Enabled
Video Off Method
: V/H SYNC +Blank
Primary IDE 1
: Enabled
Video Off After
: Standby
Secondary IDE 0
: Disabled
Modem Use IRQ
: 3
Secondary IDE 1
: Disabled
Doze Mode
: Disabled
Floppy Disk
: Disabled
Standby Mode
: Disabled
Serial Port
: Enabled
Suspend Mode
: Disabled
Parallel Port
: Disabled
HDD Power Down
: Disabled
Throttle Duty Cycle
: 62.5%
PCI/VGA Active Monitor
: Disabled
Soft-Off by PWR-BTTN
: Instant-Off
PowerOn by Ring
: Disabled
Resume by Alarm
: Disabled
ESC : Quit
Ç
È
Æ
Å
: Select Item
IRQ 8 Break Suspend
: Disabled
F1 : Help
PU/PD/+/- : Modify
F5 : Old Values
(Shift) F2 : Color
F6 : Load BIOS Defaults
F7 : Load Setup Defaults
ACPI function
ACPI stands for Advanced Configuration Power Interface. The default
setting of this field
Enabled
.
Power Management
This field allows you to select the type of power saving management
modes. There are fours selections for Power Management.
Min. Power Saving
Minimum power management
Max. Power Saving
Maximum power management.
User Define
Each of the ranges is from 1 min. to 1hr.
Except for HDD Power Down which
ranges from 1 min. to 15 min.
(Default)
NOTE: In order to enable the CPU overheat protection feature, the
Power Management field should not be set to Disabled.
PM Control by APM
This field allows you to use the Advanced Power Management device to
enhance the Max. Power Saving mode and stop the CPU’s internal clock. If
the Max. Power Saving is not enabled, this will be preset to NO.
Содержание CI7BM
Страница 11: ...Chapter 1 Introduction CI7BM User s Manual 7 Board Dimensions ...
Страница 17: ...Chapter 2 Installations CI7BM User s Manual 13 Jumper Locations on the CI7BM ...
Страница 22: ...Chapter 2 Installations 18 CI7BM User s Manual Connector Locations on the CI7BM ...
Страница 41: ...Chapter 2 Installations CI7BM User s Manual 37 This page was intentionally left blank ...
Страница 67: ...Chapter 3 BIOS Configuration CI7BM User s Manual 63 This page was intentionally left blank ...
Страница 83: ...Chapter 7 LAN Driver Installation Guide CI7BM User s Manual 79 This page was intentionally left blank ...
Страница 87: ...Chapter8 System Monitor Utility CI7BM User s Manual 83 2 Power displays the current voltage status ...
Страница 88: ...Chapter 8 System Monitor Utility 84 CI7BM User s Manual 3 Memory displays the current memory usage status ...
Страница 99: ...Chapter 9 LANDesk Client Manager CI7BM User s Manual 95 This page was intentionally left blank ...
Страница 111: ...Appendix CI7BM User s Manual 107 Appendix A I O Port Address Map B Interrupt Request Lines IRQ ...