IBS Scherer G-50-I Скачать руководство пользователя страница 7

 

6. Operating the machine

 ___________________________________________________ 

 

 

6.1.

 

Controls 

The device is switched on with a foot-operated safety switch. 

 

6.2.

 

Assembly and adjustment 

 

6.2.1. Assembling the Parts Cleaning Device 

  Remove the packaging. 

  The device is fully assembled. 

  Remove the protective film from the support rack and place the rack in the cleaning tray. 

 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Auflagerost 

Support tray

 

Ablaufschlauch 

Drain hose

 

50l Fass mit Pumpe 

50 litre drum with pump

 

Wanne Typ WF, optional 

Tray, type WF, optional

 

 
6.2.2. Assembling the IBS special pump  

  Insert the pump 

(1)

 into the drum and push the drum into the device

Feed the mains plug 

(2)

 and plug connector 

(3)

 for the foot-operated switch through the round hole in the rear 

wall of the housing. 

  Screw the return connector supplied into the ¾-inch hole in the 50-litre drum. 

  Push the return hose onto the return connector. 

  Attach the top end of the return hose to the outlet connector on the tray. 

Содержание G-50-I

Страница 1: ...Original operating instructions IBS Parts Cleaning Device Type G 50 W Type G 50 I All devices have been tested and certified Visit our website www ibs scherer com...

Страница 2: ...ice stability 3 5 2 Space required 3 5 3 Acceptable ambient conditions 3 5 4 Preventing electrostatic charge 3 5 4 1 IBS pump 3 5 4 1 1 Parts Cleaning Device 3 5 4 1 2 Electrical connection by the cus...

Страница 3: ...se _______________________________________________________________________ The IBS Parts Cleaning Device has been designed for cleaning of oily and greasy metal parts e g machine parts motors and hous...

Страница 4: ...the cleaning agent declines the drum must be replaced with a new drum of IBS Special Cleaning Agent 3 2 Safety information See section 6 4 Transport ___________________________________________________...

Страница 5: ...t by a qualified electrician 5 4 1 2 Electrical connection by the customer Installation at the customer s premises must be carried out by an approved electrician in accordance with VDE requirements an...

Страница 6: ...BS recommends a danger area of 1 m around the device The danger area identified by means of a risk assessment Must be designated a fire hazard area Must remain free of obstructions in order to allow u...

Страница 7: ...rost Support tray Ablaufschlauch Drain hose 50l Fass mit Pumpe 50 litre drum with pump Wanne Typ WF optional Tray type WF optional 6 2 2 Assembling the IBS special pump Insert the pump 1 into the drum...

Страница 8: ...n and troubleshooting Fault Cause Solution Pump not working No power Check that mains plug is plugged in Pump is faulty Replace pump Pump not pumping Liquid level in drum is too Check liquid level if...

Страница 9: ...pump with foot switch 2222040 IBS special pump without foot switch 2222057 IBS special pump with foot switch 2222080 IBS special pump with foot switch 2222066 Splash guard 2222060 Support rack slatted...

Страница 10: ...pe BK 50 F F2 F2 D G 50 W I K KP L M MD 2120022 IBS collecting tray type WM St 2120023 IBS collecting tray type WK St 2120024 IBS collecting tray type WK 50 2120021 IBS collecting tray type WF 2222063...

Страница 11: ...eatment of industrial items using liquids or vapours Part 3 Safety of machines using flammable cleaning liquids EN 349 1993 A1 2008 Safety of machinery Minimum gaps to avoid crushing of parts of the h...

Страница 12: ...eatment of industrial items using liquids or vapours Part 3 Safety of machines using flammable cleaning liquids EN 349 1993 A1 2008 Safety of machinery Minimum gaps to avoid crushing of parts of the h...