![IBOS CamBoss Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/ibos/camboss/camboss_original-operating-instructions_609274011.webp)
CamBoss
10 / 19
Inspection of piping connections
Connection left/right are the functions that perform rotation of head by 90° to the respective
side, then a 360° rotation around the axis. This function is used to check the pipe connections.
Laser measurement
Activates the lasers on the camera head that can be used to create a distance calibration
within the image in the DigiCAN software (pipe connection gap or crack width).
Illumination
The illumination of the space in front of the camera is provided via LEDs integrated directly
into the camera head or the pantograph. The intensity can be controlled continuously by a
LED1 or LED2 potentiometers.
Return the camera to the zero position
To set the camera to its zero position, press "0" POS button on the LCD panel. The zero camera
head position means that the head will look straight ahead, perpendicularly to the earth's axis.
Trolley and winch speed correction
When reversing the trolley, it is possible to use the function of fine corrections. The function
is used to gently change the speed of the cable winding, and this the speed the trolley, so that
the cable is wound as quickly as the trolley moves. The function is suitable for optimum cable
winding at long distances of reversing trolley. When the joystick is moved backwards
(reversing travel), the text JEMNÁ KOREKCE (Fine correction) and a two-digit readings +20 to
-20 appear on the bottom of the LCD display on the control panel. When reversing, [+] and [-]
buttons can be used to gently vary the speed, at which the cable and the trolley are wound. If
you press [-] button, the trolley speed will decrease, if you press [+] button, the trolley speed
will increase.
Reversing camera
When reversing/moving back, you can use the rear-view camera located in the body of
camera trolley.
Localizer probe
The following description of the controls is identical for the trolley's probe, as well as for the
probes of axial cameras. When the probe is active, the red LED on the probe body lights up.
You can determine the position of the probe and this of the camera (or trolley) using the probe
signal detector. The probe signal detector is available from IBOS a.s.
Distance travelled indication
The CamBoss is provided with an odometer indicating the travelled distance (cable unwound),
which is located on the winch cable. The measured value is displayed on the display of the
control panel. This indication can be changed using the buttons on the LCD panel.
The [0] button resets the counter, the [+] button adds 10 cm and [-] deducts 10 cm.