STORAGE:

The   pump   and   booster   set   must   be   protected   against   frost.   All   and   any   damage 
resulting from frost is not subject to warranty repair.
If the device is placed in a non-heated room in the winter season and it is not used, it 
must be disassembled and the water inside it must be drained. Due to the fact that 
some water may remain in the pump, it is recommended to store the device in a room 
with positive temperature.

If the pump or booster set is not used for a period exceeding one day, it must be  
unplugged.   It   must   be   remembered   that   in   case   of   absence   of   the   household 
residents, any leakage that can occur in the home water system or suction installation 
will result in booster pump switching on which can lead to flooding of the house or, in 
case of leakage in the suction installation - to pump failure.
Damage resulting from installation leakage are not subject to warranty repairs.

QB-60, WZ, WZ, WZC, WZCH, WZI type pumps require unclogging after a standstill 
period without water. Clogging results from sticking of the rotor to the housing due to 
the water sediments resulting from evaporation. In order to unclog the pump, move the 
pump shaft before starting the device. To facilitate this, insert a flat screwdriver in the 
shaft slit visible in the central part of the fan casing. If unclogging by means of a 
screwdriver is impossible, remove three screws securing the rotor casing, remove the 
cover revealing the rotor and turn it several times.

DEVICE DISPOSAL:

The used product is subject to disposal as wastes only in selective waste collection 
systems   organised   by   the   Netowrk   of   Communal   Electric   and   Electronic   Waste 
Collection   Centres.   The   customer   is   entitled   to   return   the   used   equipment   to   the 
network   of   the   electric   equipment   distributor,   at   least   for   free   and   directly,   if   the 
returned device is of proper type and fulfils the same function as a newly purchased 
device.

Device CE marking year............................................................

(entered by the seller based on the device rating plate)

6

Содержание QB-60

Страница 1: ...f the well from which you are going to pump the water is sufficient i e whether the efficiency of the purchased pump is not too high in relation to the well capacity Installation of the pump that is too large can stop the water flow in the suction pipe and result in dry pump operation without water Pumps with capacities of 100 l min and higher require new efficient wells This equipment is not inte...

Страница 2: ...al section x 0 15for diameter 1 2 25 m In total the negative pressure is 5_2 25 7 25 m In this example the negative pressure of 8 m is not exceeded and the booster pump should operate without problems If the negative pressure of 8 m is exceeded during operation e g when the water level decreases during pumping the booster pump can be damaged due to operation without water flow This type of failure...

Страница 3: ... for the pump or booster set must be 230V 50Hz with earthing The suction pipe must be connected to the pump by means of the suction port using a flexible non collapsible hose hose available for purchase from the guarantor so that the pipe stress is not transferred to the pump NOTE do not use anti vibration hoses in metal plait for connection of the pump and suction pipe This type of hoses can be u...

Страница 4: ...nection ELECTRIC INSTALLATION The electric network used to power the device must be compliant with data provided on the rating plate The device plug must be connected to a socket with earthing The manufacturer and guarantor are not liable for any damage to people or property resulting from lack of proper earthing The yellow green core of the connection cable is earthing The powering network must b...

Страница 5: ...t once every 3 months during continuous use or at the beginning of the spring summer season if the booster set is used in a recreational plot or when excessively frequent switch on of the pump is found more frequently than usual The air pressure in the tank can be checked when the booster set is unplugged and the tap is open When the water pressure in the installation drops to zero the air pressur...

Страница 6: ... repairs QB 60 WZ WZ WZC WZCH WZI type pumps require unclogging after a standstill period without water Clogging results from sticking of the rotor to the housing due to the water sediments resulting from evaporation In order to unclog the pump move the pump shaft before starting the device To facilitate this insert a flat screwdriver in the shaft slit visible in the central part of the fan casing...

Страница 7: ...and booster sets with 50L and lower capacity tanks are qualified as category I pressure devices Adam Jastrzębski 23 11 2008 TECHNICAL DATA TYPE Motor power Coil Current Power supply voltage Max efficiency Max head height Max suction depth Suction disccharge port Highest admissible booster set pressure W A V l min m m P s max bar JET100A a 1100 2 4 230 60 50 8 1 x 1 4 AJ 50 60 1100 2 4 230 60 50 8 ...

Отзывы: