The suction pipe must be tight on its entire length. Any potential leakage, e.g. on the 
connections, result in air suction by the pump. In the best scenario, the pump will not 
reach   the   declared   parameters.   Finally,   the   pump   will   operate   without   water   flow, 
causing its failure. Results of such a failure are not subject to warranty repair.
The direction of the suction pipe gradient must be towards the intake, so that no 
syphon is present at any point that would preclude full and exact filling of the system 
with water.

Prior to start of the pump or booster set, fill the suction pipe and pump with water. The 
prerequisite for problem-free start is full flooding of the suction pipe and hydraulic part 
of the pump. The system can be flooded through the flood plug on the suction body of 
the pump or through the discharge port.

CAUTION!!   Starting   the   pump   or   booster   set   without   previous   flooding   results   in 
seizure and damage to the plastic parts of the pumping parts. This can also cause 
irreparable   motor   damage.   In   such   a   case,   only   paid   repair   is   available   and   no 
warranty repair is provided.
After flooding, the discharge port must be connected with the pumping installation. It is 
recommended to use an anti-vibration hose in a metal plain (available for purchase 
from the guarantor) for the purpose of connection.

ELECTRIC INSTALLATION:

The electric network used to power the device must be compliant with data provided 
on the rating plate.

The device plug must be connected to a socket with earthing. The manufacturer and 
guarantor are not liable for any damage to people or property resulting from lack of  
proper earthing.

The yellow-green core of the connection cable is earthing.

The powering network must be equipped with an installation, overcurrent motor switch, 
e.g. M611, securing the motor against overload. In order to provide maximum overload 
protection for the motor, the switch must be set to maximum coil current provided on 
the rating plate. The device can operate without this protection, but in case of a failure 
caused by overload, the repair costs are incurred by the user.

The powering installation must be equipped with a residual current device, with rated 
making current In not exceeding 30 mA.  The manufacturer and guarantor are not 
liable for any damage to people or property resulting from use of power supply without 
a proper switch.

STARTUP AND OPERATION:

The first start must be conducted with open taps and valves in order to pump out air 
particles that could be present in the installation. The start occurs after the plug is 
connected to the electric network. The taps and valves can be closed after the air 
particles are pumped out. If the suction installation is tight, when the tank is filled the 
booster set should reach the pressure causing the pressure switch to stop the motor.

4

Содержание QB-60

Страница 1: ...f the well from which you are going to pump the water is sufficient i e whether the efficiency of the purchased pump is not too high in relation to the well capacity Installation of the pump that is too large can stop the water flow in the suction pipe and result in dry pump operation without water Pumps with capacities of 100 l min and higher require new efficient wells This equipment is not inte...

Страница 2: ...al section x 0 15for diameter 1 2 25 m In total the negative pressure is 5_2 25 7 25 m In this example the negative pressure of 8 m is not exceeded and the booster pump should operate without problems If the negative pressure of 8 m is exceeded during operation e g when the water level decreases during pumping the booster pump can be damaged due to operation without water flow This type of failure...

Страница 3: ... for the pump or booster set must be 230V 50Hz with earthing The suction pipe must be connected to the pump by means of the suction port using a flexible non collapsible hose hose available for purchase from the guarantor so that the pipe stress is not transferred to the pump NOTE do not use anti vibration hoses in metal plait for connection of the pump and suction pipe This type of hoses can be u...

Страница 4: ...nection ELECTRIC INSTALLATION The electric network used to power the device must be compliant with data provided on the rating plate The device plug must be connected to a socket with earthing The manufacturer and guarantor are not liable for any damage to people or property resulting from lack of proper earthing The yellow green core of the connection cable is earthing The powering network must b...

Страница 5: ...t once every 3 months during continuous use or at the beginning of the spring summer season if the booster set is used in a recreational plot or when excessively frequent switch on of the pump is found more frequently than usual The air pressure in the tank can be checked when the booster set is unplugged and the tap is open When the water pressure in the installation drops to zero the air pressur...

Страница 6: ... repairs QB 60 WZ WZ WZC WZCH WZI type pumps require unclogging after a standstill period without water Clogging results from sticking of the rotor to the housing due to the water sediments resulting from evaporation In order to unclog the pump move the pump shaft before starting the device To facilitate this insert a flat screwdriver in the shaft slit visible in the central part of the fan casing...

Страница 7: ...and booster sets with 50L and lower capacity tanks are qualified as category I pressure devices Adam Jastrzębski 23 11 2008 TECHNICAL DATA TYPE Motor power Coil Current Power supply voltage Max efficiency Max head height Max suction depth Suction disccharge port Highest admissible booster set pressure W A V l min m m P s max bar JET100A a 1100 2 4 230 60 50 8 1 x 1 4 AJ 50 60 1100 2 4 230 60 50 8 ...

Отзывы: