The   device   is   not   adjusted   to   pump   caustic,   flammable,   destructive   or   explosive 
substances (e.g. petrol, nitro, oil, etc.), foodstuffs or salty water. Failures caused by 
pumping of liquids other than pure water are not subject to warranty repairs.
The maximal temperature of the pumped water is 35

o

C.

The device is not adjusted to pump water containing excessive amounts of mineral 
elements causing deposition of scale on the pumping elements. Operation in such 
conditions results in premature wear and tear of the operating elements of the pump. 
In such a case, only paid repair of the pump is available.

DEVICE INSTALLATION:

The device must be installed in a closed ventilated room, on levelled horizontal plane.  
The room must be selected in such a manner, so that the device is not exposed to high 
levels of humidity or frost.

It is prohibited to expose the device to impact of atmospheric factors (rain, snow).  
Operation in such conditions as too high humidity levels can result in electrocution 
hazard or failure of the motor or pressure switch. In case of such a failure, only paid  
repair is available.

The power supply for the pump or booster set must be 230V/50Hz, with earthing.

The suction pipe must be connected to the pump by means of the suction port, using a  
flexible non-collapsible hose (hose available for purchase from the guarantor), so that 
the pipe stress is not transferred to the pump.

NOTE: do not use anti-vibration hoses in metal plait for connection of the pump and 
suction pipe. This type of hoses can be used on the pumping side of the pump. Use of  
such a hose on the suction side can cause sucking it in - jamming, closing the flow 
through the hose and resulting in pump operation without water flow and, thus, in a  
failure. This type of damage is not subject to warranty repair.
In case of ring wells, it is necessary to install a suction rose at the end of the suction 
pipe with a check valve. For bored wells, the check valve must be installed directly 
over the filter.
The length of the ring well must be selected in such a manner that the check valve and  
the rose are at least 30 cm under the lowest possible water level and not lower than 30 
cm from the well bottom.

It must be remembered that if the suction hose emerges during operation of the pump, 
it will result in leakage in the suction system, causing operation of the pump without 
water flow. Results of such a failure are not subject to warranty repair.

3

Содержание QB-60

Страница 1: ...f the well from which you are going to pump the water is sufficient i e whether the efficiency of the purchased pump is not too high in relation to the well capacity Installation of the pump that is too large can stop the water flow in the suction pipe and result in dry pump operation without water Pumps with capacities of 100 l min and higher require new efficient wells This equipment is not inte...

Страница 2: ...al section x 0 15for diameter 1 2 25 m In total the negative pressure is 5_2 25 7 25 m In this example the negative pressure of 8 m is not exceeded and the booster pump should operate without problems If the negative pressure of 8 m is exceeded during operation e g when the water level decreases during pumping the booster pump can be damaged due to operation without water flow This type of failure...

Страница 3: ... for the pump or booster set must be 230V 50Hz with earthing The suction pipe must be connected to the pump by means of the suction port using a flexible non collapsible hose hose available for purchase from the guarantor so that the pipe stress is not transferred to the pump NOTE do not use anti vibration hoses in metal plait for connection of the pump and suction pipe This type of hoses can be u...

Страница 4: ...nection ELECTRIC INSTALLATION The electric network used to power the device must be compliant with data provided on the rating plate The device plug must be connected to a socket with earthing The manufacturer and guarantor are not liable for any damage to people or property resulting from lack of proper earthing The yellow green core of the connection cable is earthing The powering network must b...

Страница 5: ...t once every 3 months during continuous use or at the beginning of the spring summer season if the booster set is used in a recreational plot or when excessively frequent switch on of the pump is found more frequently than usual The air pressure in the tank can be checked when the booster set is unplugged and the tap is open When the water pressure in the installation drops to zero the air pressur...

Страница 6: ... repairs QB 60 WZ WZ WZC WZCH WZI type pumps require unclogging after a standstill period without water Clogging results from sticking of the rotor to the housing due to the water sediments resulting from evaporation In order to unclog the pump move the pump shaft before starting the device To facilitate this insert a flat screwdriver in the shaft slit visible in the central part of the fan casing...

Страница 7: ...and booster sets with 50L and lower capacity tanks are qualified as category I pressure devices Adam Jastrzębski 23 11 2008 TECHNICAL DATA TYPE Motor power Coil Current Power supply voltage Max efficiency Max head height Max suction depth Suction disccharge port Highest admissible booster set pressure W A V l min m m P s max bar JET100A a 1100 2 4 230 60 50 8 1 x 1 4 AJ 50 60 1100 2 4 230 60 50 8 ...