in  the  pipeline.  It  is  recommended  to  flush  the  pipeline  in  which  the  pump  is 
installed prior to installation. 

The 

pump 

must 

be 

installed in such a manner 
that  its  shaft  is  in  a 
horizontal  position.  Ports 
can  be  in  a  different 
position  than  shown  in 
this  picture,  however,  the 
motor  shaft  must  always 
be in a horizontal position. 

Installation of the pump in a manner where the shaft is in vertical position results 
in fast wear and tear of the bearings and failure of the pump. In such a case, only 
paid repair is available. 

 

The arrow cast on the corpus indicates the direction of water flow. 
The pump should be installed in such a manner which allows for cable inlet 

in the control panel box was placed in the bottom. This type of installation protects 
against  water  penetration  into  the  cable  box  in  case  of  leakage  in  the  water 
installation.  Device  destruction  caused  by  pouring  water  into  the  terminal  box 
from the outside is not subject to warranty repair. 
Despite the possibility of pump operation in water pumping in a vertical downward 
direction,  the  manufacturer  recommends  the  installation  which  makes  it  pump 
water vertically upward or horizontally. 

ELECTRIC CONNECTION:

 

The electric network used to power the pump must be compliant with data 
provided on the rating plate. The pump is fitted with a cable with a plug intended 
for its connection to the socket with earthing. 

The pump must be connected to a network with active earthing. 

The manufacturer and guarantor are not liable for any 

damage to people or property resulting from lack of proper earthing. 

 

 

Vertical 

motor axis 

WRONG !

 

 

 

 

Horizontal 

motor axis 

GOOD ! 

Содержание BETA

Страница 1: ...arising from potential device failure caused by the use that is inconsistent with instructions of its use NOTE failure to observe the instructions included in the manual can result in hazard for persons properties in which they are installed environment and the pump itself CAUTION This equipment is not intended for use by persons including children with reduced motor sensory or mental capacities o...

Страница 2: ...pumping of clean water with no solid or abrasive particles Pumping water containing mechanical contamination results in fast wear and tear of the pump and in consequence it its failure In such a case only paid repair is available The pump is not adjusted to pump caustic flammable destructive or explosive substances e g petrol nitro oil etc foodstuffs or salty water Failure caused by pumping of the...

Страница 3: ...bottom This type of installation protects against water penetration into the cable box in case of leakage in the water installation Device destruction caused by pouring water into the terminal box from the outside is not subject to warranty repair Despite the possibility of pump operation in water pumping in a vertical downward direction the manufacturer recommends the installation which makes it ...

Страница 4: ...uipped with a residual current device with rated making current In not exceeding 30 mA The manufacturer and guarantor are not liable for any damage to people or property resulting from supplying the pump with power without a proper switch PUMP OPERATION CONTROL Upon launch of the pump the display of the power consumption meter will show the current power consumption of the pump When the message tw...

Страница 5: ...rameters of pump operation depending on the selected operation mode are presented in the diagram example diagram for pump BETA 25 60 RECOMMENDED SETPOINTS DEPENDING ON THE TYPE OF CENTRAL HEATING CO INSTALLATION 1 If there is a two pipe central heating installation routed in the house i e one pipe serves as the supply line for all heaters in the loop and the other in parallel position is used only...

Страница 6: ...rate with a pump operating in a night mode The principle of NIGHT MODE operation The use of the night mode switch will cause the automatic system of the pump will monitor the temperature changes in flowing water If the temperature signalling unit detects temperature lowering of at least 0 1 O C min in the period of about 2 hours it will result in automatic switch the pump into night operation mode...

Страница 7: ...not exceed 70O C For 35O C of surroundings the max temp of medium is 90O C Device destruction as a result of water steam condensation is not subject to warranty repair The temperature of pump surface can never exceed 120O C Device destruction as a result of installation overheating is not subject to warranty repair PUMP DISPOSAL The used product is subject to disposal as wastes only in selective w...

Страница 8: ...to the installation Check the amount of air in the collecting container Pump capacity is too high Decrease pressure on the suction side of the device Pump is operating but installation fails to supply enough heat Panel displays a number Too low pump operation parameters Increase pressure on the suction side of the device Switch the pump setpoint into a higher operation mode EC DECLARATION OF CONFO...

Отзывы: