background image

  

 

 

Operation Instructions for deep-well pumps

: 

4SD, 4SDm, 4SG, 90QJD, 3ti, 4SKm, 4TP, 90MSC 

 
 

 

 

 

 

 

 

                                         CAUTION  Read the operation instructions before use.            
                                         For safety reasons the pump may be  operated  only by   
                                         persons who are fully acquainted with operation  
  instructions.
 

 

             CAUTION  The operation instructions constitute the main element of             
             the purchase contract. The user’s failure to comply with these  
             instructions is a default of the contract and excludes any claims 
resulting from potential damage caused by improper use.
 

 
 
 
 

 

             

 

CAUTION  Non-compliance with these instructions may                           

                             cause risk to people, the environment or the pump alone. 
 

Содержание 3ti

Страница 1: ...fully acquainted with operation instructions CAUTION The operation instructions constitute the main element of the purchase contract The user s failure to comply with these instructions is a default...

Страница 2: ...ding or explosive substance e g gasoline nitro solvents petroleum etc food stuffs salt water Damage caused by pumping these types of liquids in not covered by the warranty Permitted temperature of the...

Страница 3: ...orehole with a protective strip may damage the cable insulation This may damage the pump or cause electric shock to the operator Since the motor needs cooling during operation the diameter of the bore...

Страница 4: ...bands At a great depth where the pump is installed the cable which is not mounted to the delivery pipe may break reason high weight of cable I It is recommended to lift the pump additionally at a stee...

Страница 5: ...caused to people or objects resulting to feeding the pump without proper switch Pumps 4SDM MSC reason short length of cable are supplied with separate control box equipped with capacitor overload pro...

Страница 6: ...surface on entire length The pump s support in one or several points may bend the pump and cause damage EQUIPMENT DISPOSAL The used product must be disposed as waste exclusively in selective waste co...

Страница 7: ...two veins of the feed cable on the feeding strip only for three phase motors Too high resistance during the flow through the delivery pipe hose Check if the permitted lifting height for this specific...