background image

This

 

LED

 

and

 

LEDs

 

on

 

the

 

light

 

path

 

diagnostics

 

panel

 

remain

 

lit

 

until

 

you

 

resolve

 

the

 

condition.

 

If

 

the

 

only

 

condition

 

is

 

that

 

the

 

BMC

 

log

 

is

 

full

 

or

 

almost

 

full,

 

clear

 

the

 

BMC

 

log

 

or

 

the

 

system-event

 

log

 

through

 

the

 

Configuration/Setup

 

Utility

 

program

 

to

 

turn

 

off

 

the

 

lit

 

LEDs.

 

See

 

“Using

 

the

 

Configuration/Setup

 

Utility

 

program”

 

on

 

page

 

58

 

for

 

information

 

about

 

clearing

 

the

 

logs.

 

Clear

 

the

 

logs

 

after

 

you

 

have

 

resolved

 

all

 

conditions.

 

Important:

 

If

 

the

 

server

 

has

 

a

 

baseboard

 

management

 

controller,

 

clear

 

the

 

BMC

 

log

 

and

 

system-event

 

log

 

after

 

you

 

resolve

 

all

 

conditions.

 

This

 

will

 

turn

 

off

 

the

 

information

 

LED

 

and

 

LOG

 

LED,

 

if

 

all

 

conditions

 

are

 

resolved.

 

v

   

Release

 

latch:

 

Slide

 

this

 

latch

 

to

 

the

 

left

 

to

 

access

 

the

 

light

 

path

 

diagnostics

 

panel.

 

v

   

System-error

 

LED:

 

When

 

this

 

LED

 

is

 

lit,

 

it

 

indicates

 

that

 

a

 

system

 

error

 

has

 

occurred.

 

An

 

LED

 

on

 

the

 

light

 

path

 

diagnostics

 

panel

 

is

 

also

 

lit

 

to

 

help

 

isolate

 

the

 

error.

 

v

   

Locator

 

LED:

 

When

 

this

 

LED

 

is

 

lit,

 

it

 

has

 

been

 

lit

 

remotely

 

by

 

the

 

system

 

administrator

 

to

 

aid

 

in

 

visually

 

locating

 

the

 

server.

 

In

 

multi-node

 

configurations,

 

when

 

this

 

LED

 

flashes

 

during

 

startup,

 

it

 

indicates

 

that

 

the

 

server

 

is

 

the

 

primary

 

node.

 

When

 

this

 

LED

 

is

 

lit

 

during

 

startup,

 

it

 

indicates

 

that

 

the

 

server

 

is

 

a

 

secondary

 

node.

 

v

   

Hard

 

disk

 

drive

 

activity

 

LED:

 

When

 

this

 

LED

 

is

 

flashing,

 

it

 

indicates

 

that

 

a

 

SAS

 

hard

 

disk

 

drive

 

is

 

in

 

use.

 

v

   

Power-on

 

LED:

 

When

 

this

 

LED

 

is

 

lit

 

and

 

not

 

flashing,

 

it

 

indicates

 

that

 

the

 

server

 

is

 

turned

 

on.

 

When

 

this

 

LED

 

is

 

flashing,

 

it

 

indicates

 

that

 

the

 

server

 

is

 

turned

 

off

 

and

 

still

 

connected

 

to

 

an

 

ac

 

power

 

source.

 

When

 

this

 

LED

 

is

 

off,

 

it

 

indicates

 

that

 

ac

 

power

 

is

 

not

 

present,

 

or

 

the

 

power

 

supply

 

or

 

the

 

LED

 

itself

 

has

 

failed.

 

Note:

 

If

 

this

 

LED

 

is

 

off,

 

it

 

does

 

not

 

mean

 

that

 

there

 

is

 

no

 

electrical

 

power

 

in

 

the

 

server.

 

The

 

LED

 

might

 

be

 

burned

 

out.

 

To

 

remove

 

all

 

electrical

 

power

 

from

 

the

 

server,

 

you

 

must

 

disconnect

 

the

 

power

 

cords

 

from

 

the

 

electrical

 

outlets.

Electrostatic-discharge

 

connector:

 

Connect

 

an

 

electrostatic-discharge

 

wrist

 

strap

 

to

 

this

 

connector.

 

DVD

 

drive

 

activity

 

LED:

 

(Standard

 

on

 

some

 

models

 

only)

 

When

 

this

 

LED

 

is

 

lit,

 

it

 

indicates

 

that

 

the

 

DVD

 

drive

 

is

 

in

 

use.

 

DVD-eject

 

button:

 

(Standard

 

on

 

some

 

models

 

only)

 

Press

 

this

 

button

 

to

 

release

 

a

 

CD

 

or

 

DVD

 

from

 

the

 

DVD

 

drive.

 

 

Chapter

 

1.

 

The

 

xSeries

 

460

 

and

 

MXE

 

460

 

server

 

9

Содержание xSeries MXE 460

Страница 1: ...IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 User s Guide ERserver...

Страница 2: ......

Страница 3: ...IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 User s Guide ERserver...

Страница 4: ...general information in Notices on page 85 Second Edition August 2005 Copyright International Business Machines Corporation 2005 All rights reserved US Government Users Restricted Rights Use duplicati...

Страница 5: ...the server with the power on 22 Handling static sensitive devices 22 Removing the cover and bezel 23 Installing a hot swap power supply 23 Installing an adapter 26 Installing a hot swap hard disk driv...

Страница 6: ...rogram 76 Using the baseboard management controller utility programs 78 Using the SAS SATA Configuration Utility program 79 Starting the SAS SATA Configuration Utility program 79 SerialSelect Utility...

Страница 7: ...alleert eerst de veiligheidsvoorschriften Ennen kuin asennat t m n tuotteen lue turvaohjeet kohdasta Safety Information Avant d installer ce produit lisez les consignes de s curit Vor der Installation...

Страница 8: ...f the caution or danger statement in the IBM Safety Information book For example if a caution statement begins with a number 1 translations for that caution statement appear in the IBM Safety Informat...

Страница 9: ...quipment when there is evidence of fire water or structural damage v Disconnect the attached power cords telecommunications systems networks and modems before you open the device covers unless instruc...

Страница 10: ...AUTION When laser products such as CD ROMs DVD drives fiber optic devices or transmitters are installed note the following v Do not remove the covers Removing the covers of the laser product could res...

Страница 11: ...power control button on the device and the power switch on the power supply do not turn off the electrical current supplied to the device The device also might have more than one power cord To remove...

Страница 12: ...levels are present inside any component that has this label attached There are no serviceable parts inside these components If you suspect a problem with one of these parts contact a service technicia...

Страница 13: ...ility For more information see What your server offers on page 4 and Reliability availability and serviceability on page 6 You can obtain up to date information about the server and other IBM server p...

Страница 14: ...ct xSeries 460 or MXE 460 5 Click Continue Notices and statements in this document The caution and danger statements that appear in this document are also in the multilingual Safety Information docume...

Страница 15: ...IBM EXA 32 Chipset with integrated memory and I O controller v Service processor support for Remote Supervisor Adapter II SlimLine v Light path diagnostics v Three Universal Serial Bus USB ports 2 0...

Страница 16: ...innovative IBM designs to make your Intel processor based server powerful scalable and reliable For more information see http www ibm com pc us eserver xseries xarchitecture enterprise index html Acti...

Страница 17: ...evice drivers are installed this switching occurs without data loss and without user intervention v Redundant cooling and power capabilities The redundant cooling of the fans in the server enable cont...

Страница 18: ...workgroup hardware management tool v Information and light path diagnostics LED panels v Optional service processor adapter for remote system management v Parity checking on the small computer system...

Страница 19: ...tems management industry standards v Integration into leading workgroup and enterprise systems management environments v Ease of use training and setup IBM Director also provides an extensible platfor...

Страница 20: ...drive is in use Operator information panel This panel contains controls and LEDs The following illustration shows the controls and LEDs on the operator information panel Power control button Power on...

Страница 21: ...rver In multi node configurations when this LED flashes during startup it indicates that the server is the primary node When this LED is lit during startup it indicates that the server is a secondary...

Страница 22: ...n this LED is lit it indicates that there is an active connection on the Ethernet port USB 2 connector Connect a USB device to this connector System serial connector Connect a 9 pin serial device to t...

Страница 23: ...ndicates that there is an active connection on the Ethernet port Power supply connector Connect the power cord to this connector SMP Expansion Port 1 link LED When this LED is lit it indicates that th...

Страница 24: ...ture the Wake on LAN feature can turn on the server Note When 4 GB or more of memory physical or logical is installed some memory is reserved for various system resources and is unavailable to the ope...

Страница 25: ...ing system stops functioning you can press and hold the power control button for more than 4 seconds to turn off the server v If the server is installed in a static partition pressing the power contro...

Страница 26: ...14 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 User s Guide...

Страница 27: ...illustrations in this document might differ slightly from your hardware F R O N T Memory card Hot swap power supply I O board Hot swap fans 92 mm Hot swap fans 80 mm Operator information panel Hot sw...

Страница 28: ...on of this jumper to pins 2 and 3 to bypass the power on password check Changing the position of this jumper does not affect the administrator password check if an administrator password is set If the...

Страница 29: ...llustration shows the LEDs on the memory card DIMM 1 error LED DIMM 2 error LED DIMM 3 error LED DIMM 4 error LED Light path diagnostics button Light path diagnostics button power LED Memory card erro...

Страница 30: ...ket Microprocessor 3 socket Microprocessor 3 error LED VRM 3 error LED VRM 4 error LED Microprocessor 4 error LED Microprocessor 2 error LED Microprocessor 1 error LED Microprocessor 1 socket Micropro...

Страница 31: ...4 266 MHz 64 bit PCI X slot 3 266 MHz 64 bit PCI X slot 2 266 MHz 64 bit PCI slot 1 266 MHz 64 bit Attention LED Power LED SAS internal power cable connector ServeRAID 8i I O board Active PCI cable PC...

Страница 32: ...ation shows the connectors on the SAS backplane Front of SAS backplane Back of SAS backplane SAS hard disk drive connectors SAS signal cable 2 SAS signal cable 1 SAS power 2 20 IBM xSeries 460 Type 88...

Страница 33: ...steps that involve installing or removing adapter cables v Blue on a component indicates touch points where you can grip the component to remove it from or install it in the server open or close a la...

Страница 34: ...r forearms Button long sleeved shirts before working inside the server do not wear cuff links while you are working inside the server v Do not allow your necktie or scarf to hang inside the server v R...

Страница 35: ...e server and all attached peripheral devices Disconnect all power cords then disconnect all external signal cables from the server 3 Slide the server out of the rack until the slide rails lock into pl...

Страница 36: ...ion you must either install a second power supply or use 220 V ac input v If you install or remove a power supply observe the following precautions Statement 8 CAUTION Never remove the cover on a powe...

Страница 37: ...g inside the server with the power on 2 Remove the server cover See Removing the cover and bezel on page 23 3 If you are adding a power supply to an empty power supply bay remove the cover from the ac...

Страница 38: ...3 V 32 bit or 64 bit PCI and PCI X adapters v The server scans devices and PCI X slots to assign system resources in the following order integrated Ethernet controller integrated SAS controller and t...

Страница 39: ...ted surface on the outside of the server then grasp the adapter by the top edge or upper corners of the adapter and remove it from the package 5 Remove the ServeRAID 8i adapter from the package using...

Страница 40: ...off the server and peripheral devices and disconnect the power cords and all external cables 3 Remove the server cover see Removing the cover and bezel on page 23 and determine which PCI X expansion s...

Страница 41: ...an adapter avoid touching the components and gold edge connectors on the adapter Make sure that the adapter is correctly seated in the connector Incorrectly seated adapters might cause damage to the I...

Страница 42: ...drives when you are installing the server in a rack configuration install the server in the rack before installing the hard disk drives v You do not have to turn off the server to install hot swap dr...

Страница 43: ...laced If the green hard disk drive activity LED is flashing the drive is being accessed 2 If the server will be configured for RAID operation using a ServeRAID controller you must configure the disk a...

Страница 44: ...to save new configuration information to the BIOS when installing or removing DIMMs The only exception is if you replace a DIMM that was marked as Disabled in the Memory Settings menu In this case you...

Страница 45: ...there is a problem and guide you to the defective DIMM When this occurs first identify the defective DIMM then remove and replace the DIMM The following illustration shows the LEDs on the memory card...

Страница 46: ...f memory scrubbing determines that a DIMM is damaged beyond use read and write operations are redirected to the remaining good DIMMs Memory scrubbing then reports the damaged DIMM and light path diagn...

Страница 47: ...structures inside the server a Grasp the memory card by the retention levers and turn the memory card so that the connector aligns with the connector on the microprocessor board b Insert the memory ca...

Страница 48: ...b Insert the memory card into the memory card connector c Press the memory card into the connector and close the retention levers If you have other options to install or remove do so now otherwise go...

Страница 49: ...onnectors facing up Attention To avoid breaking the DIMM retaining clips or damaging the DIMM connectors open and close the clips gently 5 Open the retaining clip on each end of the DIMM connector 6 T...

Страница 50: ...he retention levers If you have other options to install or remove do so now otherwise go to Completing the installation on page 47 Hot swapping DIMMs To hot swap DIMMs complete the following steps 1...

Страница 51: ...tention To avoid breaking the DIMM retaining clips or damaging the DIMM connectors open and close the clips gently 5 Open the retaining clip on each end of the DIMM connector and remove the DIMM or DI...

Страница 52: ...g the installation on page 47 Hot adding DIMMs To hot add DIMMs and memory cards complete the following steps 1 Read the safety information that begins on page v and Installation guidelines on page 21...

Страница 53: ...by aligning the edges of the DIMM with the slots at the ends of the DIMM connector 8 Firmly press one end of the DIMM into the connector then press the other end into the connector The retaining clip...

Страница 54: ...upports up to four Intel Xeon microprocessors If you are installing two or more microprocessors they must be the same cache size and type and the same clock speed v With more than one microprocessor t...

Страница 55: ...processor in the server Install the microprocessors in the order shown in the following illustration If you install the microprocessors in the wrong order the server will not start 1 2 3 4 To install...

Страница 56: ...ops then push in on the microprocessor tray retention latches on each side of the tray and pull the tray out of the server Attention The microprocessor tray is heavy Pull the tray partially out of the...

Страница 57: ...and store it for future use 6 Remove the protective cover tape or label from the surface of the microprocessor socket if any is present 7 Lift the microprocessor release lever to the fully open positi...

Страница 58: ...heat sink retaining clip to the fully open position approximately 135 angle 12 Remove the heat sink from its package and remove the cover from the bottom of the heat sink 13 Remove the release liner...

Страница 59: ...See the Rack Installation Instructions that come with the server for complete rack installation and removal instructions Attention v Install the server only in a rack cabinet with perforated doors v D...

Страница 60: ...o interconnect the SMP Expansion Ports of two or more servers v 2 3 m XpandOnDemand Scalability cable kit comes with one 2 3 m 7 6 foot SMP Expansion cable v 2 9 m XpandOnDemand Scalability cable kit...

Страница 61: ...igurations that consist of two four or eight servers for up to 32 way operation A node is a server that is interconnected with other servers or nodes through the SMP Expansion Ports to share system re...

Страница 62: ...hat is connected to port 1 on node 1 then connect the opposite end of the cable to port 1 of node 2 Next route the cable through the node 2 cable management arm b Locate the SMP Expansion cable that i...

Страница 63: ...ion b Connect one end of an SMP Expansion cable to port 2 on node 1 then route the cable through the node 1 cable management arm Use a 2 3 m 7 6 foot SMP Expansion cable for this connection c Connect...

Страница 64: ...is connected to port 1 on node 1 then connect the opposite end of the cable to port 1 of node 4 Next route the cable through the node 4 cable management arm b Locate the SMP Expansion cable that is co...

Страница 65: ...able 2 9 m SMP Expansion cable 2 9 m SMP Expansion cable 2 9 m SMP Expansion cable 3 Connect the SMP Expansion cables to node 1 a Connect one end of an SMP Expansion cable to port 1 on node 1 then rou...

Страница 66: ...node 3 then route the cable through the node 3 cable management arm Use a 2 3 m 7 6 foot SMP Expansion cable for this connection 6 Connect the SMP Expansion cables to node 4 a Locate the SMP Expansio...

Страница 67: ...rm c Connect one end of an SMP Expansion cable to port 3 on node 7 then route the cable through the node 7 cable management arm Use a 2 3 m 7 6 foot SMP Expansion cable for this connection 10 Connect...

Страница 68: ...56 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 User s Guide...

Страница 69: ...p sequence that is set in the Configuration Setup Utility program and temporarily assign a device to be first in the startup sequence v Gigabit Ethernet controller configuration process For informatio...

Страница 70: ...ity menu is available 3 Select settings to view or change Configuration Setup Utility menu choices The following choices are on the Configuration Setup Utility main menu Depending on the version of th...

Страница 71: ...24 hour format hour minute second This choice is on the full Configuration Setup Utility menu only v System Security Select this choice to set passwords See Passwords on page 62 for more information a...

Страница 72: ...emory configuration the server automatically disables the failing pair of memory connectors and continues operating with reduced memory After the problem is corrected you must manually enable the memo...

Страница 73: ...of the error messages is displayed otherwise the log contains only numeric error codes Run the diagnostic program to get more information about error codes that occur See the Problem Determination an...

Страница 74: ...a power on password is set when you turn on the server the system startup will not be completed until you type the power on password You can use any combination of up to seven characters A Z a z and 0...

Страница 75: ...ministrator password and then forget it there is no way to change override or remove it You must replace the I O board Using the ServerGuide Setup and Installation CD The ServerGuide Setup and Install...

Страница 76: ...are levels of a ServeRAID adapter and determines whether a later level is available from the CD v Detects installed hardware options and provides updated device drivers for most adapters and devices v...

Страница 77: ...nd restart the server At this point the installation program for the operating system takes control to complete the installation Installing your operating system without ServerGuide If you have alread...

Страница 78: ...specifying the startup order of devices through the PXE boot agent utility program Starting the PXE boot agent utility program To start the PXE boot agent utility program complete the following steps...

Страница 79: ...ler lights LEDs to help you diagnose the problem and also records the error in the BMC system event log The baseboard management controller also provides the following remote server management capabil...

Страница 80: ...Console Baud Rate 19200 v Remote Console Data Bits 8 v Remote Console Parity None v Remote Console Stop Bits 1 v Remote Console Text Emulation ANSI v Remote Console Keyboard Emulation ANSI v Remote C...

Страница 81: ...ollowing line to the end of the Run gettys in standard runlevels section of the etc inittab file This enables hardware flow control and enables users to log in through the SOL console 7 2345 respawn s...

Страница 82: ...ents prompt timeout 50 default linux boot dev hda map boot map install boot boot b message boot message linear image boot vmlinuz 2 4 9 e 12smp label linux initrd boot initrd 2 4 9 e 12smp img read on...

Страница 83: ...the Linux operating system starts a LILO boot prompt is displayed instead of the graphical user interface Press Tab at this prompt to install all of the boot options that are listed To load the operat...

Страница 84: ...e that you do not have to rerun grub after making changes to this file NOTICE You have a boot partition This means that all kernel and initrd paths are relative to boot eg root hd0 0 kernel vmlinuz ve...

Страница 85: ...initrd initrd 2 4 9 e 12 img You must restart the Linux operating system after completing these procedures for the changes to take effect and to enable SOL SUSE SLES 8 0 configuration Note This proce...

Страница 86: ...ack light gray default 0 timeout 8 title linux kernel hd0 1 boot vmlinuz root dev hda2 acpi oldboot vga 791 1 initrd hd0 1 boot initrd title floppy root chainloader 1 title failsafe kernal hd0 1 boot...

Страница 87: ...mpt then press Enter to display the current boot options for the server b In the Boot Entries section locate the boot entry ID for the section with an OS friendly name of Windows Server 2003 Standard...

Страница 88: ...0 partition 1 WINDOWS OS Load Options fastdetect redirect You must restart the Windows 2003 operating system after completing this procedure for the changes to take effect and to enable SOL Installing...

Страница 89: ...system complete the following steps You must be logged in as a root user to perform these procedures 1 Go to http www ibm com pc support download the utility program and create the OSA BMC Management...

Страница 90: ...and restart the server 2 From a command line prompt type bmc_cfg and press Enter 3 Follow the instructions on the screen Using the baseboard management controller firmware update utility program Use...

Страница 91: ...st 623 to access the SOL network Type help at the smbridge prompt for more information Use the following commands in an SOL session connect Connect to the LAN Type connect ip ip_address u username p p...

Страница 92: ...guration on the server you must run ServeRAID Manager in Startable CD mode as described in the instructions in this section If you install a different type of RAID adapter in the server use the config...

Страница 93: ...t spare drive complete the following steps a Click the Spares tab b Select the physical drive that you want to designate as the hot spare drive and click the icon to add the drive 7 Click Next The Con...

Страница 94: ...ues with the secondary nodes in numeric order of the logical node IDs Creating a scalable partition To create a scalable partition complete the following steps 1 Make sure that the service processor o...

Страница 95: ...e in the following illustration is displayed a In the Scalable System Configuration field set the number of nodes that will be part of the scalable partition b In the Scalable Partition Number ID fiel...

Страница 96: ...ol Scalable Partition page to manage the scalable partition Use the Control Partition page to replace a current scalable partition with a new scalable partition You can also start or stop a scalable p...

Страница 97: ...Y OF ANY KIND EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE Some states do not allow disclaimer...

Страница 98: ...the United States other countries or both UNIX is a registered trademark of The Open Group in the United States and other countries Java and all Java based trademarks and logos are trademarks of Sun M...

Страница 99: ...f any standard hard disk drives and population of all hard disk drive bays with the largest currently supported drives available from IBM Maximum memory may require replacement of the standard memory...

Страница 100: ...88 IBM xSeries 460 Type 8872 and xSeries MXE 460 Type 8874 User s Guide...

Страница 101: ...anager 57 ServerGuide Setup and Installation CD 57 viewing 81 with ServerGuide 64 Configuration Setup Utility program 57 58 connector electrostatic discharge 9 Gigabit Ethernet 11 IXA RS485 11 keyboar...

Страница 102: ...hard disk drive 30 installing continued hot swap hard disk drive 30 memory 36 memory modules 36 microprocessor 42 OSA SMBridge management utility program 76 power supply 23 installing ServeRAID 8i 26...

Страница 103: ...n LED 9 password 62 publications 1 PXE Boot Agent Utility program 57 PXE Boot Agent Utility program continued using 66 R rack installing your server in 47 RAS features 6 release latch 9 reliability 6...

Страница 104: ...ion Web Interface 81 utility baseboard management controller utility programs 78 Configuration Setup program using 58 OSA SMBridge management utility program 78 PXE boot agent utility program 66 SAS S...

Страница 105: ......

Страница 106: ...Part Number 31R1513 Printed in USA 1P P N 31R1513...

Отзывы: