80
Hardware Maintenance Manual: xSeries 380
3.
First row test encounters an SBE, base memory test encounters memory errors
and a bad CMOS checksum was seen by BIOS.
User notification:
The BIOS will try to map out defective rows found during base
memory test but will end up in an infinite reset loop.
Upon reset, the above messages will display again on the LCD and will keep
repeating in an infinite loop.
User action:
1.
Use the out-of-band mechanism of reading System Event Log (Intel’s Server
Management software, specifically DPC, can be used for this) to determine the
location of the row of defective DIMMs from the SELViewer Utility. Replace the
defective DIMMs. If you do not have out-of-band access to SEL, then remove all
DIMMs from the system and populate the system one row at a time.
2.
Clear CMOS via the front panel or via clear CMOS jumper (see “Clearing the
CMOS register” on page 220) in order to clear previous defective DIMM history.
3.
Power on the system to continue.
Error logging:
The defective row/DIMM(s) found during this test case will be logged
to the SEL and reported on screen.
Extended memory test
The extended memory test takes effect after both the first row test and the base
memory test have passed. The Extended Memory Test will test the physical memory
above 2 GB to a maximum of the total installed memory. Any errors found will be
detected to the failing memory row and recorded into the CMOS history bits for
processing during the next reset. Since this occurs after system POST, the BIOS will
not reset the system. Instead, error messages will be displayed on the video screen.
There is a 2 GB fixed gap between the memory address 2 GB to 4 GB that is reserved
for PCI. This 2 GB of memory addresses, as seen by the processor, will not be tested.
User notification
There are two sets of messages associated with this test. The first occurs when the test
is being performed. The message is as follows:
XXXXX MB Total Memory Installed
XXXXX MB Configured
XXXXX MB Tested
Memory Errors Detected
Note:
The "memory errors detected" message will appear only if extended memory
test finds errors.
"First row test" –
displayed on the upper LCD line
"0064 MB" –
displayed on the lower LCD line
"BASE MEMORY TEST" –
displayed on the upper LCD line
"ERRORS IN MEMORY" –
displayed on the upper LCD line
"RESETTING SYSTEM" –
displayed on the lower LCD line (prior to resetting)
Содержание xSeries 380
Страница 1: ...IBM Hardware Maintenance Manual xSeries 380 ...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual xSeries 380 ...
Страница 10: ...viii Hardware Maintenance Manual xSeries 380 ...
Страница 24: ...14 Hardware MaintenanceManual xSeries 380 ...
Страница 94: ...84 Hardware MaintenanceManual xSeries 380 ...
Страница 236: ...226 Hardware Maintenance Manual xSeries 380 ...
Страница 262: ...252 Hardware Maintenance Manual xSeries 380 Processor memory complex 1 2 3 4 5 6 7 ...
Страница 277: ...Related serviceinformation 267 Statement 17 The following label indicates moving parts nearby ...
Страница 283: ...Related serviceinformation 273 ...
Страница 284: ...274 Hardware Maintenance Manual xSeries 380 ...
Страница 285: ...Related serviceinformation 275 ...
Страница 286: ...276 Hardware Maintenance Manual xSeries 380 ...
Страница 287: ...Related serviceinformation 277 ...
Страница 288: ...278 Hardware Maintenance Manual xSeries 380 ...
Страница 289: ...Related serviceinformation 279 ...
Страница 290: ...280 Hardware Maintenance Manual xSeries 380 ...
Страница 291: ...Related serviceinformation 281 ...
Страница 292: ...282 Hardware Maintenance Manual xSeries 380 ...
Страница 309: ...Related serviceinformation 299 ...
Страница 310: ...300 Hardware Maintenance Manual xSeries 380 ...
Страница 311: ...Related serviceinformation 301 ...
Страница 312: ...302 Hardware Maintenance Manual xSeries 380 ...
Страница 318: ...308 Hardware Maintenance Manual xSeries 380 PRECAUCIÓN La etiqueta siguiente indica que hay partes móviles cerca ...
Страница 322: ...312 Hardware Maintenance Manual xSeries 380 ...
Страница 323: ......