Hardware Maintenance Manual: xSeries 380
Using BIOS Setup
This section describes the BIOS Setup Utility. Use this utility to change the server
configuration defaults. You can run the utility with or without an operating system
present on the server. Setup stores most of the configuration values in battery-backed
CMOS. The rest of the values are stored in flash memory. The values take effect when
you boot the server. POST uses these values to configure the hardware. If the values
endfor
Provides a delimiter for loop constructs (scripts only)
endif
Provides a delimiter for IF THEN constructs (scripts only)
err [level]
Sets or displays the error level
for v ar in <set>
Provides loop constructs (scripts only)
guid [-b] [sname]
Dumps known guid ids
help [-b] [internal_command]
Displays help information
if [not] condition then
Provides conditional constructs (scripts only)
load driver_name
Loads a driver
ls [-b] [dir] [dir] ...
Obtains directory listings
map [-bdvr] [sname[:]]
[handle]
Maps sname to device path
mem [address] [size]
[;MMIO]
Dumps Memory or Memory Mapped IO
memmap [-b]
Dumps memory map
mkdir dir [dir]
Creates a new directory
mm address [Width] [;Type]
[n]
Memory Modify: type=Mem, MMIO, IO, PCI, [n] for
noninteractive mode when inside a .nsh file
mode [col row]
Sets or gets the current text mode
mount BlkDevice [sname[:]]
Mounts a file system on a block device
PalProc arg1 [arg2] [arg3]
[arg4]
Makes a PAL call
pause
Prompts to quit or continue (scripts only)
pci [bus_dev ] [func]
Displays PCI device information
reset [reset_string]
Performs a cold reset
rm file/dir [file/dir]
Removes files or directories
set [-bdv ] [sname] [value]
Sets or gets env ironment variables
stall microseconds
Delays for the specified number of microseconds
time [hh:mm:ss]
Gets or sets the time
type [-a] [-u] [-b] file
Displays the contents of a file
ver
Displays version information
vol fs [volume_label]
Sets or displays a volume label
Table 3. EFI Shell Commands.
Command
Description
Содержание xSeries 380
Страница 1: ...IBM Hardware Maintenance Manual xSeries 380 ...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual xSeries 380 ...
Страница 10: ...viii Hardware Maintenance Manual xSeries 380 ...
Страница 24: ...14 Hardware MaintenanceManual xSeries 380 ...
Страница 94: ...84 Hardware MaintenanceManual xSeries 380 ...
Страница 236: ...226 Hardware Maintenance Manual xSeries 380 ...
Страница 262: ...252 Hardware Maintenance Manual xSeries 380 Processor memory complex 1 2 3 4 5 6 7 ...
Страница 277: ...Related serviceinformation 267 Statement 17 The following label indicates moving parts nearby ...
Страница 283: ...Related serviceinformation 273 ...
Страница 284: ...274 Hardware Maintenance Manual xSeries 380 ...
Страница 285: ...Related serviceinformation 275 ...
Страница 286: ...276 Hardware Maintenance Manual xSeries 380 ...
Страница 287: ...Related serviceinformation 277 ...
Страница 288: ...278 Hardware Maintenance Manual xSeries 380 ...
Страница 289: ...Related serviceinformation 279 ...
Страница 290: ...280 Hardware Maintenance Manual xSeries 380 ...
Страница 291: ...Related serviceinformation 281 ...
Страница 292: ...282 Hardware Maintenance Manual xSeries 380 ...
Страница 309: ...Related serviceinformation 299 ...
Страница 310: ...300 Hardware Maintenance Manual xSeries 380 ...
Страница 311: ...Related serviceinformation 301 ...
Страница 312: ...302 Hardware Maintenance Manual xSeries 380 ...
Страница 318: ...308 Hardware Maintenance Manual xSeries 380 PRECAUCIÓN La etiqueta siguiente indica que hay partes móviles cerca ...
Страница 322: ...312 Hardware Maintenance Manual xSeries 380 ...
Страница 323: ......