Diagnostics
25
pnt0-13
add_intr_handler failed! Interrupts already enabled.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings.
pnt0-14
Cannot locate hardware.
Explanation:
The SunSoft Solaris driver cannot find any Ethernet controller. Action: Verify that
the Ethernet controller is enabled. If the Ethernet controller is enabled, run the diagnostic
programs.
pnt0-15
No more devices to open.
Explanation:
The SunSoft Solaris driver cannot find any more Ethernet controllers.
Action:
Verify that additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or
replace the Ethernet adapter that fails to respond. If the problem persists, run the diagnostic
programs.
pnt0-17
Device fault...Reset initiated!
Explanation:
The SunSoft Solaris driver has been reset due to a device fault. Action: Verify that
additional IBM Netfinity 10/100 Fault Tolerant Adapters are present or replace the Ethernet
adapter that fails to respond. If the problem persists, run the diagnostic programs.
pnt0-19
IRQ found for PCnet hardware does not match space.c (or pnt.conf)!
Explanation:
This is a warning message referring to the interrupt request (IRQ) that the SunSoft
Solaris driver found in the system.
Action: Ignore this message if you are sure that this is what you want to do. Otherwise, run the
NETCONFIG program to match the hardware settings
pnt0-20
add_intr_handler failed! Unknown interrupt type.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-21
add_intr_handler failed! Out of range interrupt number.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
•
Modify your hardware settings.
•
Run the NETCONFIG program to search for another Ethernet controller.
pnt0-22
add_intr_handler failed! Out of range IPL.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings. Run the NETCONFIG program to search for another
Ethernet controller.
pnt0-23
add_intr_handler failed! Vector already occupied.
Explanation:
The interrupt request (IRQ) that was specified, or the IRQ that was found, conflicts
with other devices in the server.
Action:
Modify your hardware settings.
Table 5. UNIX LLI driver messages for the Ethernet controller.
Содержание x 340 Series
Страница 1: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 46: ...38 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 112: ...104 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 140: ...132 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 157: ...Related service information 149...
Страница 158: ...150 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 159: ...Related service information 151...
Страница 160: ...152 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 161: ...Related service information 153...
Страница 162: ...154 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 163: ...Related service information 155...
Страница 164: ...156 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 177: ...Related service information 169...
Страница 178: ...170 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 179: ...Related service information 171...
Страница 187: ......