![IBM x 340 Series Скачать руководство пользователя страница 136](http://html1.mh-extra.com/html/ibm/x-340-series/x-340-series_hardware-maintenance-manual_4277654136.webp)
128
Hardware Maintenance Manual: xSeries 340 Model 6RY
System shutdown
Refer to the following tables when experiencing system shutdown related to voltage
or temperature problems.
Voltage related system shutdown
System under recommended voltage for "X"
v
(level-warning; indicated
voltage supply under nominal value; value
for "X" can be +12, -12, or +5)
1.
Check connections to power subsystem
2.
Replace power supply
3.
Replace power backplane
System under recommended voltage on 3.3
v
(level-warning; 3.3 volt
supply under nominal value)
1.
Check connections to power subsystem
2.
Replace power supply
3.
Replace power backplane
System under recommended X current
(level-non-critical; system drawing less
current than recommended on voltage "X")
1.
See “Power checkout” on page 26.
"X" V bus fault
(level-critical;
overcurrent condition on "X" voltage bus)
1.
Check for short circuit on "X" voltage bus
2.
See“Power checkout” on page 26.
12V "X" bus fault
(level-critical;
overcurrent condition on 12 volt "X" voltage
bus)
1.
Check for short circuit on 12 volt "X" voltage bus
2.
See “Power checkout” on page 26.
5V fault
(level-critical; overcurrent
condition on 5 V subsystem)
1.
Check for short circuit on 5 v bus
2.
See“Power checkout” on page 26.
240 VA fault
(level-critical; overcurrent
or overvoltage condition in power
subsystem)
1.
See “Power checkout” on page 26.
Message
Action
System shutoff due to "X" current over
max value
(level-critical; system
drawing too much current on voltage "X"
bus)
1.
See “Power checkout” on page 26.
System shutoff due to "X" current under
min value
(level-critical;
current on voltage bus "X" under minimum
value)
1.
See “Power checkout” on page 26.
System shutoff due to "X" V over voltage
(level-critical; system shutoff due to "X"
supply over voltage)
1.
Check power supply connectors
2.
Replace power supply
3.
Replace power backplane
System shutoff due to "X" V under voltage
(level-critical system shutoff due to "X"
supply under voltage)
1.
Check power supply connectors
2.
Replace power supply
3.
Replace power backplane
Message
Action
Содержание x 340 Series
Страница 1: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 2: ......
Страница 3: ...IBM Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 46: ...38 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 112: ...104 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 140: ...132 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 157: ...Related service information 149...
Страница 158: ...150 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 159: ...Related service information 151...
Страница 160: ...152 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 161: ...Related service information 153...
Страница 162: ...154 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 163: ...Related service information 155...
Страница 164: ...156 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 177: ...Related service information 169...
Страница 178: ...170 Hardware Maintenance Manual xSeries 340 Model 6RY...
Страница 179: ...Related service information 171...
Страница 187: ......