Chapter 2. Configuration menu (root/config)
23
LIPF8 Recovery
When a port is already inserted into a zone, the port transforms F8
Failure notifications into F7 Initialization notifications. When this
occurs, the port is bypassed and F7 Initialization notifications are
allowed in the zone. Once the initialization is complete, the Bad
Zone Recovery Policy is operational and prevents a port that
continues to transmit F8 Failure notifications from inserting into the
zone.
Note:
If this policy is disabled while the Bad Zone Recovery policy
is enabled, a zone that does go down will still allow the Bad
Zone Recovery policy to reset the zone and allow ports to
be reinserted.
When enabled, this policy prevents devices that send F8 Failure
notifications from inserting into a zone. The ability to remove
devices that generate F8 Failure notifications automatically and
instantaneously guarantees continual system operation.
When disabled, this policy allows devices that send F8 Failure
notifications to insert into a zone and does not consider F8 Failure
notifications when determining whether to insert a device or not.
SEOC
Serial ID Exchange on Connect. This policy is an internal
diagnostic setting and should remain disabled.
Smart Insertion
This policy is the default operating mode for all ports and
determines what the switch looks for prior to allowing a port to
insert into a zone. When the policy is enabled, an external device is
sent an F7 Initialization notification by the switch until an F7
Initialization notification is received from the device. Once an F7
Initialization notification is received, the port is inserted in the zone.
This policy takes precedence over all other policies. When this
policy is disabled, no additional policies are operational, and as
long as a port transmits a signal of the correct frequency and
amplitude, the port will be allowed in the zone.
Clear on Stall
In situations where the switch is operating in switching mode, some
devices may fall into an operating mode where the device has
opened a target but has not released the connection to the target.
When this policy is enabled, the switch can detect this condition
and automatically recover when this situation arises.
No Comma
The switch detects the amount of time a data stream has gone
without receiving a comma. The time setting is set to 100 (.001
seconds). When this policy is enabled, the switch bypasses the
disruptive port when the threshold is exceeded.
OS Err
Ordered set (OS) errors are detected and counted for each
individual port. When this policy is enabled, a port is bypassed
when its OS count exceeds the threshold setting. The threshold
setting is based on the number of ordered set errors identified in 10
seconds.
Note:
The threshold can be adjusted.
Table 15. Port information (continued)
Field
Description
Содержание TotalStorage L10
Страница 2: ......
Страница 3: ...IBM TotalStorage Storage Switch 2006 Model L10 CLI Reference Guide GC26 7652 00...
Страница 8: ...2006 Model L10 Storage Switch vi...
Страница 10: ...2006 Model L10 Storage Switch viii...
Страница 20: ...2006 Model L10 Storage Switch 8...
Страница 66: ...2006 Model L10 Storage Switch 54...
Страница 74: ...2006 Model L10 Storage Switch 62...
Страница 82: ...2006 Model L10 Storage Switch 70...
Страница 84: ...2006 Model L10 Storage Switch 72...
Страница 86: ...2006 Model L10 Storage Switch 74...
Страница 95: ......
Страница 96: ...GC26 7652 00...