b.
The
Add
Device
window
opens.
Enter
the
TCP/IP
address
of
Controller
B
in
the
Host
name
or
IP
address
field
and
click
Add
to
add
the
DS4000
storage
server
in
the
DS4000
Storage
Manger
Client
management
domain.
c.
Click
Close
to
close
the
Add
Device
window.
Note:
If
this
is
an
upgrade
from
an
existing
DS4000
storage
server
with
version
5.4x.xx.xx
firmware
or
earlier
and
there
is
an
entry
for
this
DS4000
storage
server
in
the
DS4000
Storage
Manger
Client
Enterprise
Management
window,
delete
this
entry
before
you
add
controller
B
to
the
Enterprise
Management
window.
To
delete
the
entry,
right-click
the
entry
and
select
Remove
Device
from
the
pull-down
menu.
Click
Yes
when
the
Remove
Device
confirmation
window
opens.
When
you
are
done,
continue
to
Downloading
the
firmware
to
controller
B
Perform
the
following
steps
to
download
the
firmware
and
NVSRAM
to
controller
B
of
the
DS4000
Storage
Server:
1.
In
the
Enterprise
Management
window,
right
click
the
DS4000
storage
server
name
and
select
Manage
Device
to
open
the
Subsystem
Management
window.
Note:
A
Partially
Managed
Notice
window
might
open,
warning
that
the
storage
subsystem
that
you
are
trying
to
manage
has
a
controller
that
has
not
yet
been
added
to
the
Enterprise
Management
window.
Click
Yes
to
launch
the
Subsystem
Management
window
for
this
DS4000
controller
anyway.
2.
In
the
Subsystem
Management
window,
click
Storage
Subsystem
→
Download
→
NVSRAM
to
load
the
NVSRAM
file
to
Controller
B.
When
the
NVSRAM
Download
window
opens.
3.
Select
the
directory
that
contains
the
NVSRAM
file,
then
select
the
name
of
the
NVSRAM
file.
Click
OK
to
close
the
window
and
continue.
4.
Click
Yes
when
the
Confirm
Download
window
opens.
The
Confirm
Download
window
closes
and
the
Downloading
window
opens
and
shows
the
status
of
the
firmware
download.
5.
One
of
two
windows
displays:
v
If
you
receive
the
message
NVSRAM
download
successful
displayed
in
the
Downloading
window,
click
Done
to
close
the
Downloading
window
and
then
continue
with
step
v
If
you
see
an
error
window
displaying
a
Controller
Download
Timeout
error,
power
off
and
then
power
on
the
DS4000
storage
server.
Then
verify
that
the
NVSRAM
was
downloaded
correctly
to
Controller
B
of
the
storage
server.
To
verify
that
the
correct
NVSRAM
version
was
downloaded,
click
View
→
Storage
Subsystem
Profile
.
In
the
Storage
Subsystem
Profile
window,
look
for
the
correct
NVSRAM
file
version
under
the
All
tab.
–
If
the
NVSRAM
was
downloaded
correctly,
continue
with
step
Appendix
C.
Upgrading
the
controller
firmware
for
DS4300,
DS4400,
and
DS4500
(DS4000
EXP710
only)
95
Содержание TotalStorage FAStT EXP700
Страница 2: ......
Страница 108: ...76 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 132: ...100 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 150: ...118 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 156: ...124 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 157: ......
Страница 158: ...Part Number 25R0398 Printed in USA gc26 7735 00 1P P N 25R0398...