v
The
Failed
Unconfigured
Drive
icon
(
)
displayed
for
drive
slots
that
contain
drives.
v
The
Failed
Configured
Drive
icon
(
)
displayed
for
drive
slots
that
contain
drives.
10.
Restore
I/O
activity
to
the
DS4000
storage
server.
11.
After
you
have
completed
the
ESM
upgrade
process,
you
may
be
required
to
return
the
original
DS4000
EXP700
1740
ESMs
(FRU
19K1287)
to
IBM.
Refer
to
the
separate
instructions
included
with
the
upgrade
kit
for
return
processing
information
for
the
DS4000
EXP700
ESMs
you
are
replacing.
Hot-case
ESM
upgrade
procedure
In
the
hot-case
ESM
upgrade
procedure,
you
upgrade
the
DS4000
EXP700
ESMs
while
the
storage
subsystem
remains
powered
on.
Note:
It
is
recommended
that
you
schedule
the
hot-case
ESM
upgrade
during
a
non-peak
(low-usage)
I/O
period
for
the
following
reasons:
v
The
DS4000
storage
server
drive
loops/channels
will
be
disturbed
with
FC
Loop
Initialization
events
every
time
the
ESM
is
replaced.
v
One
of
the
drive
loops
in
the
redundant
drive
loop
will
be
down
during
the
upgrade,
reducing
the
maximum
data
bandwidth
to
the
drives
by
one-half.
Attention:
The
hot-case
ESM
upgrade
procedure
requires
that
both
loops
(drive
channels)
in
the
redundant
drive
loop
that
contains
the
DS4000
EXP700s
that
you
are
upgrading
be
in
an
optimal
state.
If
you
perform
the
upgrade
process
with
one
drive
loop
(drive
channel)
in
non-optimal
state,
your
arrays
might
fail,
causing
loss
of
data
access
and
possibly
loss
of
data.
If
you
not
sure
that
your
drive
loops
are
optimal,
or
if
your
environment
allows
you
to
power
down
the
storage
subsystem
in
a
non-emergency
situation,
it
is
recommended
that
you
use
the
instead
of
the
hot-case
ESM
upgrade
procedure.
Contact
IBM
support
for
help
if
required.
Note:
You
must
perform
the
hot-case
upgrade
procedure
one
redundant
drive
loop
at
a
time.
Attention:
If
you
are
not
upgrading
all
of
the
DS4000
EXP700s
in
the
redundant
drive
loop,
or
if
you
are
upgrading
additional
DS4000
EXP700s
in
redundant
drive
loop
that
includes
both
DS4000
EXP700s
and
DS4000
EXP710s,
you
must
follow
the
intermixing
requirements
for
drive
loops
that
include
both
DS4000
EXP700s
and
DS4000
EXP710s.
See
Failure
to
do
so
can
result
in
drive
loop
performance
problems
due
to
excessive
time-outs
and
LIPs
and
possibly
failed
drives.
1.
Before
you
begin
the
upgrade
procedure,
perform
a
full
system
backup
and
save
the
storage
subsystem
profile.
2.
Upgrade
the
DS4000
Storage
Manager
client
to
version
9.1
or
later.
3.
Upgrade
the
ESM
firmware
for
all
DS4000
EXP700s
to
version
9326
or
later.
4.
Upgrade
the
controller
firmware
to
version
6.10.xx.xx
or
later.
Attention:
No
I/O
activity
can
be
present
during
the
firmware
upgrade
from
version
5.4x.xx.xx
or
earlier
to
version
6.10.xx.xx
or
later.
88
IBM
TotalStorage
DS4000
EXP700
and
EXP710
Storage
Expansion
Enclosures:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage FAStT EXP700
Страница 2: ......
Страница 108: ...76 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 132: ...100 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 150: ...118 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 156: ...124 IBM TotalStorage DS4000 EXP700 and EXP710 Storage Expansion Enclosures Installation User s and Maintenance Guide...
Страница 157: ......
Страница 158: ...Part Number 25R0398 Printed in USA gc26 7735 00 1P P N 25R0398...