![IBM TotalStorage DS4800 Скачать руководство пользователя страница 182](http://html2.mh-extra.com/html/ibm/totalstorage-ds4800/totalstorage-ds4800_user-installation-and-maintenance-manual_4104542182.webp)
Table
24.
DS4800
Symptom-to-FRU
index
Problem
indicator
Component
Possible
cause
Possible
solutions
Amber
Needs
Attention
LED
on
RAID
controller
Needs
Attention
LED
RAID
controller
offline
If
you
have
placed
the
controller
offline,
use
the
DS4000
Storage
Manager
client
software
to
place
it
online.
If
one
controller
has
been
placed
offline
by
the
other
controller,
contact
IBM
support.
(This
is
the
case
if
you
use
the
DS4000
Storage
Manager
client
software
to
make
repeated
attempts
to
bring
an
offline
controller
online,
but
the
controller
keeps
reverting
back
to
an
offline
state.)
RAID
controller
failure
If
the
RAID
controller
Needs
Attention
LED
is
on
and
the
Service
Action
Allowed
LED
for
that
RAID
controller
is
lit,
replace
the
RAID
controller.
If
the
Service
Action
Allowed
LED
for
the
RAID
controller
is
not
lit,
perform
additional
diagnostics
to
identify
other
component
failures.
Replace
the
other
failed
components
before
replacing
the
RAID
controller.
Drive
bypass
LED
Fibre-channel
cable
is
not
attached
to
the
storage
expansion
enclosure
Connect
the
fibre-channel
cable
to
the
enclosure
port;
check
other
connections.
No
incoming
signal
detected
Reattach
the
SFPs
and
fibre-channel
cables.
Verify
that
the
fibre
channel
cables
are
in
good
condition
and
that
there
are
no
cable
management
issues
(such
as
using
plastic
ties
to
wrap
the
cables
or
bending
the
cable
loops
to
less
than
1.5
inches).
Verify
the
SFPs
are
working
properly.
Use
the
wrap-plug
coupler
kit
that
ships
with
the
DS4800
and
the
wrap-plug
instructions
in
the
DS4000
Problem
Determination
Guide
.
Replace
input
and
output
SFPs
or
cables
as
necessary.
Amber
Needs
Attention
LED
on
(continued)
Overall
DS4800
Configuration
Needs
Attention
LED
(located
on
interconnect-
battery
unit)
General
system
error
Indicates
that
a
Needs
Attention
LED
somewhere
in
the
DS4800
storage
subsystem
configuration,
including
all
attached
storage
expansion
enclosures,
has
turned
on.
(Check
for
amber
LEDs
on
DS4800
components
as
well
as
all
attached
storage
expansion
enclosures.)
Use
the
DS4000
Storage
Manager
software
to
diagnose
server
problems.
Various
DS4800
components
Multiple
component
failures
Do
not
randomly
replace
components
in
the
DS4800.
This
might
result
in
a
subsystem
shutdown,
causing
a
loss
of
data
availability.
Use
the
DS4000
Storage
Manager
client
program
to
identify
the
failed
components.
Identify
and
replace
the
failed
power
supply-fan
components
first
before
fixing
any
other
failed
components.
160
IBM
System
Storage
DS4800
Storage
Subsystem:
Installation,
User’s,
and
Maintenance
Guide
Содержание TotalStorage DS4800
Страница 1: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 00...
Страница 2: ......
Страница 3: ...IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide GC26 7845 00...
Страница 18: ...xvi IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 22: ...xx IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 55: ...ds48020 Figure 12 DS4800 front rack mounting template Chapter 2 Installing the storage subsystem 33...
Страница 68: ...46 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 114: ...92 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 154: ...132 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 200: ...178 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 202: ...180 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 205: ...ds48021 Figure 102 DS4800 rear rack mounting template Appendix C Rack mounting templates 183...
Страница 206: ...184 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 226: ...204 IBM System Storage DS4800 Storage Subsystem Installation User s and Maintenance Guide...
Страница 233: ......
Страница 234: ...Part Number 23R1992 Printed in USA GC26 7845 00 1P P N 23R1992...